TOPGREENER TDOS5-JD

TOPGREENER TDOS5-JD dvigubos apkrovos judesio jutiklio jungiklio naudojimo instrukcija

Model: TDOS5-JD | Brand: TOPGREENER

1. Įvadas

This manual provides detailed instructions for the installation, operation, and maintenance of your TOPGREENER TDOS5-JD Dual Load Motion Sensor Switch. This device is designed to automatically control two separate loads, such as lights and a fan, based on occupancy or vacancy detection using Passive Infrared (PIR) technology. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Saugos informacija

3. Pakuotės turinys

4. Produkto ypatybės

5. Montavimas

Prieš pradėdami: Ensure power is OFF at the circuit breaker. This device is for single-pole installations only and requires a ground wire.

  1. Išjungti maitinimą: Suraskite keičiamą jungiklį valdantį grandinės pertraukiklį ir išjunkite jį. Patikrinkite, ar maitinimas išjungtas, naudodami įtampos matuoklį.tage testeris.
  2. Pašalinti esamą jungiklį: Carefully remove the wall plate and unscrew the existing switch from the wall box. Disconnect the wires.
  3. Identifikuokite laidus: You should have a Line (hot) wire, two Load wires (one for each load, e.g., light and fan), and a Ground wire. This switch does not require a neutral wire.
  4. Wire the Sensor Switch: Connect the wires from the wall box to the corresponding wires on the TDOS5-JD switch using wire nuts.
    • Prijunkite Line (hot) wire from the wall box to the switch's Line wire.
    • Prijunkite Load 1 wire (e.g., for lights) from the wall box to the switch's Load 1 wire.
    • Prijunkite Load 2 wire (e.g., for fan) from the wall box to the switch's Load 2 wire.
    • Prijunkite Žemės viela from the wall box to the switch's Ground wire.
  5. Sumontuokite jungiklį: Carefully fold the wires into the wall box and secure the switch with the provided screws. Attach the wall plate.
  6. Atkurti maitinimą: Įjunkite maitinimą grandinės pertraukikliu.
  7. Apšilimo laikotarpis: After installation, allow 1-2 minutes for the device to warm up and calibrate before it functions correctly.
Diagram of TOPGREENER TDOS5-JD sensor switch components and warm-up instruction

1 paveikslas: Components of the TDOS5-JD sensor switch, indicating the PIR sensor, Load 1/2 ON/OFF buttons, LED indicator, and a note about the warm-up period after installation. It also highlights that a ground wire is required and no neutral wire is needed.

TOPGREENER TDOS5-JD sensor switch being installed into a wall box

2 paveikslas: An image showing the TOPGREENER TDOS5-JD motion sensor switch being carefully inserted into a standard electrical wall box during the installation process.

6. Operacija

Once installed and powered, the TDOS5-JD switch will operate according to the selected mode (Occupancy or Vacancy) and configured settings.

Person carrying laundry basket, demonstrating hands-free lighting with the sensor switch

3 paveikslas: A person carrying a laundry basket walks into a room, and the lights automatically turn on, illustrating the hands-free lighting capability of the motion sensor switch.

Bathroom with lights and fan controlled by the dual load sensor switch

4 paveikslas: A modern bathroom setting where the TOPGREENER dual load sensor switch controls both the overhead lights and the exhaust fan automatically, demonstrating its energy-saving potential.

7. Pritaikymas ir nustatymai

The TDOS5-JD switch offers adjustable settings for time delay, sensitivity (range), and operating mode. These settings are located behind the faceplate.

  1. Prieigos nustatymai: Gently pry open the outer cover of the switch to reveal the adjustment dials and mode switch.
  2. Laiko uždelsimo reguliavimas: Use a small screwdriver to turn the 'TIME' dial to select the desired delay: Test (15 seconds), 5 minutes, 10 minutes, 20 minutes, or 30 minutes.
  3. Adjust Sensor Range: Use a small screwdriver to turn the 'RANGE' dial to adjust the motion detection sensitivity from 1 (lowest) to 4 (highest).
  4. Pasirinkite veikimo režimą: Use the small switch labeled 'OCCD OCCS VACD' to choose your desired mode:
    • OCCD: Dual Occupancy Mode
    • OCCS: Single Occupancy Mode
    • VACD: Laisvų darbo vietų režimas
Diagram showing how to adjust timer, range, and mode on the sensor switch

5 paveikslas: A detailed diagram illustrating the steps to customize the sensor switch settings. It shows how to open the cover, and then adjust the 'Time' dial (Test, 5, 10, 20, 30 Min), 'Range' dial (1-4), and the 'Mode Select' switch (OCCD, OCCS, VACD).

Bathroom scene with a close-up of the sensor switch's adjustable time delay settings

6 paveikslas: An image depicting a modern bathroom with the sensor switch installed on the wall. A magnified inset shows the adjustable time delay and range dials, emphasizing the customization options for automatic light control.

8. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Lights/Fan do not turn ON with motion.No power; incorrect wiring; sensor blocked; incorrect mode; range too low.Check circuit breaker. Verify wiring connections. Ensure sensor lens is clear. Confirm correct operating mode (OCCS/OCCD). Increase sensor range.
Lights/Fan stay ON too long or turn OFF too quickly.Incorrect time delay setting; continuous motion detected; walk-through feature activated.Adjust time delay setting. Ensure no constant motion within sensor's view. Understand walk-through feature behavior.
Lights/Fan turn ON without apparent motion (false triggers).Sensor too sensitive; heat sources or air drafts; sensor facing high-traffic area.Decrease sensor range. Relocate sensor away from heat sources (HVAC vents, direct sunlight) or drafts. Adjust sensor direction if possible.
Timer not functioning as expected (e.g., only extreme settings work).Dial mechanism issue; specific unit calibration.Carefully re-adjust the time dial. If issue persists, contact customer support.
One load works, but the other does not.Incorrect wiring for the non-working load; faulty bulb/fan.Verify wiring connections for Load 1 and Load 2. Test the bulb or fan directly to ensure it is functional.

9. Specifikacijos

10. Priežiūra

The TOPGREENER TDOS5-JD motion sensor switch requires minimal maintenance.

11. Garantija ir palaikymas

TOPGREENER products are designed for reliability and performance. For specific warranty information, including terms and conditions, please refer to the warranty documentation provided with your purchase or visit the official TOPGREENER website. For technical support or assistance with troubleshooting, please contact TOPGREENER customer service.

Gamintojas: TOPGREENER

Kontaktinė informacija: Please visit the TOPGREENER official websvetainę, kurioje rasite naujausią kontaktinę informaciją ir pagalbos išteklius.