1. Įvadas
This manual provides essential instructions for the installation, operation, and maintenance of your FSP iFP600 Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installing or operating the unit to ensure proper function and safety. The FSP iFP600 is designed to provide reliable power backup and surge protection for your electronic devices.

1.1 vaizdas: priekis view of the FSP iFP600 UPS, showcasindėl savo kompaktiško dizaino ir integruoto LCD ekrano.
2. Saugos instrukcijos
Please adhere to these important safety guidelines during installation, operation, and maintenance of the UPS:
- Neatidarykite UPS korpuso.asing. Viduje nėra dalių, kurias galėtų aptarnauti vartotojas. Visus techninės priežiūros darbus patikėkite kvalifikuotiems techninės priežiūros darbuotojams.
- Do not connect appliances that could overload the UPS, such as laser printers, vacuum cleaners, or heaters.
- Įsitikinkite, kad UPS yra prijungtas prie įžeminto kintamosios srovės maitinimo lizdo.
- Avoid placing the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Position the UPS in a well-ventilated area to prevent overheating.
- In case of fire, use a dry chemical extinguisher. Water can be hazardous.
- The battery inside the UPS is not user-replaceable. Battery replacement should only be performed by qualified personnel.
3. Produktas baigtasview
The FSP iFP600 UPS provides reliable power protection for your critical electronics. It features a compact design and an intuitive LCD display for monitoring status.
3.1 Pakuotės turinys
Atidarius pakuotę, patikrinkite, ar yra visi komponentai ir ar jie nepažeisti:
- FSP iFP600 UPS Unit
- Vartotojo vadovas (šis dokumentas)
- Maitinimo laidas
- USB ryšio kabelis

Image 3.1: The FSP iFP600 UPS shown alongside its retail packaging, illustrating the product's presentation.
3.2 Galinio skydelio komponentai
Familiarize yourself with the connections on the rear panel of the UPS:

3.2 pav.: Išsamus view of the FSP iFP600 UPS rear panel, highlighting connection points.
- Išparduotuvės: Two SCHUKO type outlets for connecting protected equipment.
- AC įvestis: Prijungia UPS prie pagrindinio elektros tinklo.
- Fuse/Breaker: Overcurrent protection for the UPS.
- USB ryšys: Port for connecting to a computer for monitoring and management.
- Combo RJ11/RJ45 Surge Protection: Provides surge protection for telephone/network lines.
4. Sąranka ir diegimas
Follow these steps to set up your FSP iFP600 UPS:
- Išpakavimas: Atsargiai išimkite UPS iš pakuotės. Patikrinkite, ar nėra jokių transportavimo pažeidimų.
- Vieta: Place the UPS on a flat, stable surface in a clean, cool, and well-ventilated area. Ensure adequate clearance around the unit for airflow.
- Pradinis įkrovimas: Connect the UPS to a standard grounded AC outlet using the provided power cord. Allow the unit to charge for at least 4-6 hours before initial use to ensure optimal battery performance. The UPS will charge whether it is turned on or off.
- Prijungimo įranga: Plug your computer, monitor, and other critical electronic devices into the UPS outlets (A). Do not connect surge suppressors or power strips to the UPS outlets.
- USB ryšys (neprivaloma): Connect the USB cable from the UPS USB port (D) to your computer's USB port to enable power management software features (software not included, typically downloaded from manufacturer's websvetainė).
- RJ11/RJ45 Protection (Optional): For surge protection of your telephone or network line, connect the incoming line to the 'IN' port of the Combo RJ11/RJ45 (E) and connect the 'OUT' port to your device.
5. Naudojimo instrukcijos
5.1 Įjungimas / išjungimas
- Norėdami įjungti: Paspauskite ir palaikykite priekiniame skydelyje esantį maitinimo mygtuką maždaug 2 sekundes, kol išgirsite pyptelėjimą ir įsijungs LCD ekranas.
- Norėdami išjungti: Press and hold the power button for approximately 2 seconds until you hear a beep and the LCD display turns off.
5.2 Informacija LCD ekrane
The FSP iFP600 features an LCD display that provides real-time status information. The display is touch-sensitive for navigating information.

Image 5.1: The LCD display of the FSP iFP600 UPS, indicating voltage output and its touch-screen functionality.
The LCD display typically shows:
- Įvesties tomastage
- Išėjimas ttage
- Akumuliatoriaus įkrovimo lygis
- Apkrovos lygis
- Operating Mode (e.g., AC mode, Battery mode)
- Warning/Fault Indicators
5.3 Battery Mode Operation
When the utility power fails or fluctuates outside acceptable limits, the UPS will automatically switch to battery mode. During battery mode, the UPS will provide power to connected equipment from its internal battery. An audible alarm will sound to indicate battery operation.
6. Priežiūra
Tinkama priežiūra užtikrina jūsų UPS ilgaamžiškumą ir patikimumą.
- Valymas: UPS išorę valykite minkšta, sausa šluoste. Nenaudokite skystų ar aerozolinių valiklių.
- Akumuliatoriaus priežiūra: To maximize battery life, ensure the UPS is connected to AC power and fully charged. If the UPS is stored for an extended period, recharge it every three months to prevent battery degradation.
- Baterijos keitimas: The internal battery (12V / 7Ah x1) is not user-serviceable. Battery replacement should only be performed by FSP-certified service personnel or a qualified technician. Incorrect battery replacement can pose a risk of explosion or injury.
- Saugykla: Store the UPS in a cool, dry place with adequate ventilation. Ensure the battery is fully charged before storage.
7. Problemų sprendimas
Refer to the following table for common issues and their solutions. If the problem persists, contact FSP support.
| Simptomas | Garsinis pavojaus signalas | Galima priežastis | Sprendimas |
|---|---|---|---|
| UPS operating on battery power | Pypsi kas 10 sekundžių | Utility power failure or fluctuation | Save work and shut down equipment if power outage is prolonged. UPS will return to AC mode when power is restored. |
| Įspėjimas apie išsikrovusią bateriją | Pypteli kas sekundę | Baterijos įkrova kritiškai žema | Immediately save work and shut down connected equipment. |
| Perkrovos būklė | Pypsi kas 0.5 sekundę | Connected equipment exceeds UPS capacity | Disconnect non-essential equipment until the alarm stops. Ensure total load is within UPS capacity. |
| UPS gedimas | Nuolat pypsi | Vidinis gedimas arba gedimas | Turn off the UPS and disconnect it from the AC outlet. Contact FSP technical support. |

Image 7.1: Excerpt from the FSP iFP series specification table, detailing alarm indicators and their meanings.
8. Specifikacijos
Detailed technical specifications for the FSP iFP600 UPS:
| Funkcija | Specifikacija |
|---|---|
| Modelis | iFP 600 |
| Talpa | 600 VA / 360 W |
| Įvesties tomastage | 110/120 Vac or 220/230/240 Vac |
| Įvesties tomastage Diapazonas | 81-145 Vac / 140-290 Vac |
| Įvesties dažnių diapazonas | 60/50 Hz (automatinis jutimas) |
| Išėjimas ttage | 110/120 Vac or 220/230/240 Vac |
| AC ttage reguliavimas (bat. režimas) | ±10 % |
| Output Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Perkėlimo laikas | Įprastai 2-6 ms |
| Bangos forma (Batt. Mode) | Imituota sinusinė banga |
| Baterijos tipas ir numeris | 12V / 7Ah x1 |
| Įprastas įkrovimo laikas | 4 valandos iki 90% talpos |
| Rodikliai | LCD Display (Touch panel with digital information) |
| Apsauga | Overload, Discharge, and Overcharge Protection |
| Prekės svoris | 9.24 svaro (4.2 kg) |
| Gaminio matmenys (IxPxH) | 11.81 x 3.98 x 5.59 colio |
| Spalva | Juoda |
| Medžiaga | Metalas |
9. Garantija ir palaikymas
FSP products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official FSP website. For technical support, troubleshooting assistance, or service inquiries, please contact FSP customer service through their official channels.
Daugiau informacijos ir palaikymo išteklių galite rasti adresu FSP Store on Amazon.