1. Įvadas
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Truma CP Classic Control Panel, model 36011-01. This control panel is designed for use with Truma Combi D6 and D6 E heating systems, allowing users to manage heating and hot water functions in recreational vehicles.
Please read this manual thoroughly before operating the device to ensure safe and efficient use. Keep this manual for future reference.
2. Saugos instrukcijos
Visada laikykitės šių saugos priemonių, kad išvengtumėte sužalojimų ar įrenginio sugadinimo:
- Prieš montuodami arba atlikdami techninę priežiūrą įsitikinkite, kad maitinimas yra atjungtas.
- Montuoti turėtų tik kvalifikuotas personalas.
- Do not expose the control panel to extreme temperatures or moisture.
- Use only genuine Truma spare parts for repairs.
- Keep children away from the control panel during operation.
3. Produktas baigtasview
The Truma CP Classic Control Panel (Model 36011-01) is a compact and intuitive interface for managing your Truma Combi heating system. It features a rotary knob for setting temperature and operating modes, along with clear indicators for system status.

3.1 paveikslas: Priekyje view of the Truma CP Classic Control Panel. Shows the central rotary knob with numerical settings (1-5) and icons for heating (60°C, 40°C) and hot water (60°C, 40°C, off).

3.2 paveikslas: Kampuotas view of the Truma CP Classic Control Panel, highlighting its compact design and the protruding rotary knob.

3.3 paveikslas: Components of the Truma CP Classic Control Panel, showing the main control unit and its separate black mounting frame.

3.4 paveikslas: Galinis view of the Truma CP Classic Control Panel, displaying the RJ45-style connection port for system integration and mounting points.
4. Sąranka ir diegimas
The Truma CP Classic Control Panel is designed for flush mounting. Ensure proper wiring and secure fastening for optimal performance.
4.1 Montavimas
- Choose a suitable, easily accessible location within the vehicle.
- Cut an appropriate opening in the mounting surface, referring to the dimensions provided in the specifications section.
- Insert the control panel into the opening and secure it using the provided screws or clips.
4.2 Elektros prijungimas
- Ensure the main power supply to the vehicle is disconnected.
- Connect the control panel to the Truma Combi heating system using the dedicated data cable (RJ45-style connector). Refer to Figure 3.4 for the connection port location.
- Prieš atkurdami maitinimą, patikrinkite, ar visos jungtys yra saugios.
5. Naudojimo instrukcijos
The control panel features a single rotary knob for all adjustments. The icons around the knob indicate the available settings.
5.1 Įjungimas / išjungimas
To turn the system on or off, rotate the knob to the 'O' position (off) or to any desired operating mode.
5.2 Kambario temperatūros nustatymas
Rotate the central knob to select the desired room temperature. The numbers 1 through 5 typically correspond to increasing temperature levels. Consult your Truma Combi system's main manual for exact temperature ranges.
5.3 Hot Water Settings
The hot water icons allow you to select the water heating mode:
- Flame icon with 60°: Heats water to approximately 60°C (140°F).
- Flame icon with 40°: Heats water to approximately 40°C (104°F).
- Circle icon: Hot water off.
5.4 Heating Mode Settings
The heating icons allow you to select the heating mode:
- Wavy lines with 60°: Heats the room to the set temperature, prioritizing heating.
- Wavy lines with 40°: Heats the room to the set temperature, with a lower priority for hot water.
6. Priežiūra
The Truma CP Classic Control Panel requires minimal maintenance. Regular cleaning and inspection are recommended.
6.1 Valymas
- Valdymo skydelio paviršių nuvalykite minkšta,amp audinys.
- Nenaudokite abrazyvinių valiklių ar tirpiklių, nes jie gali pažeisti paviršių.
6.2 Patikra
- Periodically check the control panel for any signs of physical damage or loose connections.
- Ensure the rotary knob turns smoothly and the icons are clearly visible.
7. Problemų sprendimas
If you experience issues with your Truma CP Classic Control Panel, refer to the following common problems and solutions:
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Valdymo skydelis nereaguoja | No power supply; Loose connection; Faulty unit | Check vehicle's power supply; Verify cable connections; Contact Truma support if issue persists. |
| Neteisingas temperatūros rodmuo | Sensor issue; External interference | Ensure no obstructions near temperature sensor (if applicable); Consult Truma Combi manual. |
| Hot water not heating | Incorrect mode selected; Low water pressure; Combi system fault | Verify hot water mode is active; Check water supply; Refer to Truma Combi system's troubleshooting guide. |
For more complex issues, please refer to the comprehensive troubleshooting section in your Truma Combi heating system's main user manual or contact Truma customer support.
8. Specifikacijos
- Modelis: Truma CP Classic (36011-01)
- Suderinamumas: Truma Combi D6, D6 E heating systems
- Spalva: Juoda
- Prekės svoris: 6.7 uncijos (apie 192 g)
- Gaminio matmenys: 8.9 x 6.06 x 2.01 colio (apytiksliai 22.6 x 15.4 x 5.1 cm)
- Ryšio tipas: RJ45-style data cable
9. Informacija apie garantiją
Truma products are covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Truma websvetainėje. Išsaugokite pirkimo įrodymą garantiniams reikalavimams.
10. Parama
For technical assistance, spare parts, or further inquiries, please contact Truma customer support:
- Truma Websvetainė: www.truma.com