Cisco N9K-C93180YC-FX

Cisco Nexus 9300 Series Switch Instruction Manual

Model: N9K-C93180YC-FX

1. Įvadas

This manual provides essential instructions for the safe and efficient operation of your Cisco Nexus 9300 Series Switch, model N9K-C93180YC-FX. It covers installation, basic operation, maintenance, and troubleshooting. Please read this manual thoroughly before installation and use to ensure proper functionality and to prevent damage.

2. Saugos informacija

Kad išvengtumėte sužalojimų ir įrangos sugadinimo, laikykitės šių saugos priemonių:

  • Always disconnect power before performing any service or maintenance on the switch.
  • Ensure the switch is properly grounded to prevent electrical shock.
  • Do not operate the switch in environments that exceed the specified temperature limits (maximum 40°C).
  • Keep the switch away from moisture and excessive humidity.
  • Šią įrangą turėtų montuoti ir aptarnauti tik kvalifikuoti darbuotojai.

3. Pakuotės turinys

Patikrinkite, ar jūsų pakuotėje yra šie elementai:

  • Cisco Nexus 9300 Series Switch (Model: N9K-C93180YC-FX)
  • Maitinimo laidas (-ai)
  • Stovo tvirtinimo rinkinys (jei taikoma)
  • Dokumentacija (greito paleidimo vadovas, saugos informacija)

Jei trūksta kokių nors prekių arba jos pažeistos, nedelsdami susisiekite su tiekėju.

4. Produktas baigtasview

The Cisco Nexus 9300 Series Switch, model N9K-C93180YC-FX, is a high-performance network switch designed for data center environments. It features a modular design and supports various high-speed connectivity options.

4.1 Pagrindinės savybės

  • Modulinis dizainas: Allows for flexible configuration and expansion.
  • High-Density Ports: Equipped with 48 SFP ports supporting 1 Gigabit, 10 Gigabit, and 25 Gigabit Ethernet.
  • High-Speed Uplinks: Includes 6 QSFP28 ports for 40 Gigabit and 100 Gigabit Ethernet connectivity.
  • Optical Fiber Support: Designed for optical fiber media types.
  • Didelė duomenų perdavimo sparta: Capable of up to 3600 Gigabits Per Second.

4.2 Priekinio skydelio išdėstymas

The front panel of the switch provides access to all network ports and status indicators.

Priekyje view of the Cisco Nexus 9300 Series Switch N9K-C93180YC-FX, showing 48 SFP ports and 6 QSFP28 ports.

1 paveikslas: Priekyje view of the Cisco Nexus 9300 Series Switch N9K-C93180YC-FX. This image displays the front panel, featuring 48 SFP ports arranged in rows, and 6 QSFP28 ports located on the right side, designed for high-speed optical fiber connections.

The 48 SFP ports (1/10G/25G) are typically used for connecting servers and other network devices, while the 6 QSFP28 ports (40G/100G) serve as high-bandwidth uplinks to other switches or core network infrastructure.

5. Sąranka

5.1 Stovo montavimas

The Cisco Nexus 9300 Series Switch is designed for standard 19-inch rack mounting. Use the provided rack mount kit to securely install the switch into a server rack. Ensure adequate airflow around the unit for proper cooling.

5.2 Maitinimo jungtis

  1. Ensure the power source matches the switch's voltage reikalavimai (240 voltų).
  2. Connect the power cord(s) to the power input receptacle(s) on the rear of the switch.
  3. Plug the other end of the power cord(s) into a grounded electrical outlet.
  4. Verify that the power LED on the front panel illuminates, indicating power is supplied.

5.3 Tinklo ryšiai

Connect optical fiber cables to the SFP and QSFP28 ports as required by your network topology. Ensure that compatible transceivers are used for each port type and speed.

  • For 1/10G/25G connections, use appropriate SFP/SFP+/SFP28 transceivers and optical fiber cables.
  • For 40G/100G connections, use appropriate QSFP+/QSFP28 transceivers and optical fiber cables.

5.4 Pradinė konfigūracija

For initial configuration and management access, connect a console cable from a management workstation to the console port on the switch. Refer to the Cisco Nexus 9000 Series documentation for detailed command-line interface (CLI) configuration instructions.

6. Jungiklio valdymas

6.1 Maitinimo įjungimas/išjungimas

  • Maitinimas: Once connected to a power source, the switch will typically power on automatically. Observe the system status LEDs.
  • Išjungti: To power off, gracefully shut down the operating system (if applicable) and then disconnect the power cord(s).

6.2 Būsenos indikatoriai

The front panel features various LED indicators to provide visual status of the switch's operation:

  • Sistemos šviesos diodas: Rodo bendrą sistemos būklę (pvz., žalia – normali, geltona – įspėjimas, raudona – kritinė).
  • Maitinimo šaltinio šviesos diodai: Indicate the status of installed power supplies.
  • Fan Module LEDs: Indicate the status of fan modules.
  • Prievado šviesos diodai: Each network port has an LED to indicate link status and activity (e.g., solid green for link, blinking for activity, off for no link).

Consult the official Cisco documentation for a detailed explanation of each LED's behavior.

7. Priežiūra

7.1 Valymas

Regularly clean the exterior of the switch and ensure ventilation openings are free from dust and debris. Use a soft, dry cloth. Do not use liquid or aerosol cleaners directly on the unit.

7.2 Firmware atnaujinimai

Reguliariai tikrinkite „Cisco“ palaikymo tarnybą website for available firmware updates. Keeping the switch's firmware up-to-date ensures optimal performance, security, and access to new features. Follow the instructions provided by Cisco for the update process.

8. Problemų sprendimas

This section provides basic troubleshooting steps for common issues. For more complex problems, refer to Cisco's official documentation or contact technical support.

8.1 Nėra galios

  • Verify that the power cord(s) are securely connected to both the switch and the power outlet.
  • Patikrinkite maitinimo lizdą su kitu įrenginiu, kad įsitikintumėte, jog jis veikia.
  • Inspect the power supply unit(s) for any visible damage.

8.2 Prievado jungties problemos

  • Ensure the optical fiber cables are correctly connected and not damaged.
  • Verify that the transceivers (SFP, QSFP28) are properly seated and compatible with both the switch and the connected device.
  • Check the configuration of the port on both the switch and the connected device.
  • Test with a known good cable and transceiver.

8.3 System Error Indicators

If the System LED indicates an error (e.g., amber or red), consult the Cisco Nexus 9000 Series documentation for specific error codes and recommended actions. This usually points to hardware failures or critical system issues.

9. Specifikacijos

FunkcijaDetalė
ModelisN9K-C93180YC-FX
Prekės ženklasCisco
GamintojasCISCO SISTEMOS – ĮMONĖ
Prievadų skaičius54 (48 x 1/10G/25G SFP, 6 x 40G/100G QSFP28)
Ethernet technologija10 Gigabit Ethernet, 40 Gigabit Ethernet, 100 Gigabit Ethernet
Duomenų perdavimo sparta3600 gigabitas per sekundę
Sąsajos tipasSFP, QSFP28
Palaikomas medijos tipasOptinis pluoštas
ModulinisTaip
Bylos medžiagaMetalas
Gaminio matmenys (I x P x A)17.28 x 22.48 x 1.73 colio
Prekės svoris17.2 svaro
Viršutinės temperatūros įvertinimas40 laipsniai Celsijaus
ttage240 voltų
UPC683332256231

10. Garantija ir palaikymas

This Cisco Nexus 9300 Series Switch is offered as an Amazon Renewed product. As such, it has been professionally inspected and tested to function and appear like new. It is backed by the Amazon Renewed Guarantee, which provides eligibility for replacement or refund if you are not satisfied with your purchase.

For detailed technical support, software downloads, and comprehensive documentation, please refer to the official Cisco Systems website. For inquiries related to your Amazon Renewed purchase, please contact Amazon customer service or your reseller.

Susiję dokumentai - N9K-C93180YC-FX

Preview „sFlow“ konfigūravimas „Cisco NX-OS“ įrenginiuose
Išsamus sFlow konfigūravimo vadovas (Samp„Flow“) „Cisco NX-OS“ tinklo įrenginiuose, apimantis srauto stebėjimo prielaidas, gaires, numatytuosius nustatymus ir nuoseklias konfigūravimo procedūras.
Preview Cisco vPC Fabric Peering Configuration Guide - Release 12.1.3
Learn how to configure vPC Fabric Peering on Cisco Nexus switches using Cisco NDFC. This guide covers virtual peer link creation, conversion, QoS settings, and limitations for Release 12.1.3.
Preview Cisco Nexus Dashboard Data Broker Overview ir konfigūracijos vadovas
ir baigtaview of the Cisco Nexus Dashboard Data Broker, detailing its features, supported hardware, system requirements, and prerequisites for deployment in network environments.
Preview „Cisco Nexus 9000“ serijos NX-OS ePBR konfigūravimo vadovas, 10.2(x) leidimas
This guide provides detailed instructions for configuring Enhanced Policy-Based Redirect (ePBR) on Cisco Nexus 9000 Series switches running NX-OS, covering L2 and L3 configurations, platform support, service chaining, and load balancing for network administrators.
Preview „Cisco Nexus 9000“ serijos NX-OS patvirtinto mastelio vadovas, 10.2(7)M leidimas
Šiame vadove pateikiamos išsamios patikrintos mastelio keitimo ribos „Cisco Nexus 9000“ serijos komutatoriams, kuriuose veikia NX-OS 10.2(7)M versija. Tai svarbus šaltinis tinklo architektams ir inžinieriams, kuriame nurodomos maksimalios palaikomos vertės įvairioms funkcijoms ir konfigūracijoms.
Preview „Cisco Nexus 9000“ serijos NX-OS paslaugų kokybės konfigūravimo vadovas, 7.x leidimas
Išsamus vadovas, kaip konfigūruoti paslaugų kokybės (QoS) funkcijas „Cisco Nexus 9000“ serijos komutatoriuose, kuriuose veikia NX-OS. Sužinokite apie klasifikavimą, žymėjimą, policijos darbą, eilių sudarymą ir planavimą, siekiant optimizuoti tinklo srautą.