ACR PLB-400

ACR ResQLink 400 asmeninio lokatoriaus švyturėlio naudotojo vadovas

Model: PLB-400 | Brand: ACR

1. Įvadas

The ACR ResQLink 400 is a compact, buoyant, GPS-enabled Personal Locator Beacon (PLB) designed to provide a direct link to rescue services in an emergency. When activated, it transmits a powerful 406 MHz distress signal to the Cospas-Sarsat satellite system, along with your precise GPS location, alerting search and rescue efforts worldwide. This device is intended for use in outdoor emergencies across various activities including hiking, hunting, boating, and fishing.

ACR ResQLink 400 Personal Locator Beacon

Image: The ACR ResQLink 400 Personal Locator Beacon, a compact, bright yellow and clear device.

Person hiking with ACR ResQLink 400 attached to backpack

Image: The ResQLink 400 attached to a backpack during a hike, demonstrating portability.

2. Pagrindinės savybės

3. Sąranka ir registracija

Before using your ResQLink 400, it is critical to register your beacon with the appropriate national authority. In the United States, this is the National Oceanic and Atmospheric Administration (NOAA). Registration is free and mandatory. It provides search and rescue forces with vital information about you and your vessel/activity, which can significantly aid in a rescue operation.

For detailed activation instructions, please refer to the video below:

Video: ACR ResQlink 400 + 425 Activation Guide. This video demonstrates the steps to activate your Personal Locator Beacon in an emergency.

Initial Registration Steps:

  1. Visit the official beacon registration webjūsų šalies svetainė (pvz., NOAA for USA).
  2. Locate your beacon's Unique Identifier Number (UIN) or Hex ID, typically found on the device label.
  3. Complete the online registration form with accurate personal and emergency contact information.
  4. Keep your registration information up-to-date, especially if your contact details or emergency contacts change.

4. Operating the ResQLink 400 in an Emergency

The ResQLink 400 is designed for simple, rapid deployment in life-threatening situations. Follow these steps carefully:

  1. Deploy the Antenna: Slide the antenna cover up and extend the antenna fully. Ensure it is positioned at a 90-degree angle to the beacon and has a clear view dangaus, kad palydovų priėmimas būtų optimalus.
  2. Activate the Beacon: Press and hold the red "ON" button for approximately 2 seconds until the red LED light begins to flash. The device will start acquiring GPS coordinates and transmitting the distress signal.
  3. Confirm GPS Acquisition: Once GPS coordinates are acquired, the red LED will turn green, indicating a successful position fix. The strobe light will also begin to flash.
  4. Išlaikyti poziciją: Leave the beacon in an open area with an unobstructed view of the sky. Do not turn it off until rescue personnel confirm your safety.
Person holding ACR ResQLink 400 on a boat

Image: A person holding the ACR ResQLink 400 Personal Locator Beacon on a boat, demonstrating its use in a marine environment.

5. Self-Test Procedure

Regular self-testing ensures your ResQLink 400 is functioning correctly. Perform a self-test monthly or before any extended trip.

Video: ACR ResQlink 400 + 425 Self-Test Guide. This video provides instructions on how to perform a self-test on your Personal Locator Beacon.

Steps for Self-Test:

  1. Antenos išdėstymas: Slide the antenna cover up and extend the antenna fully.
  2. Initiate Self-Test: Press and hold the "T" (Test) button for approximately 2 seconds.
  3. Observe LEDs: The green LED will flash once, followed by a second green LED flash. If you have the "View" model, the display will confirm "SELF TEST PASS".
  4. Svarbi pastaba: During the self-test, ensure you do not touch the antenna. Holding the antenna can interfere with the test and potentially cause it to fail.

If the self-test fails (e.g., red LED flashes, no display message, or "FAIL" message), consult the troubleshooting section or contact ACR support.

6. Priežiūra ir priežiūra

7. Problemų sprendimas

problemaGalima priežastisSprendimas
Self-Test Fails (Red LED)Antenna not deployed correctly, low battery, internal fault.Ensure antenna is fully extended and not obstructed. Check battery expiration. If issue persists, contact ACR support.
No GPS Acquisition during activationUžstojo view of sky, device not stationary.Pereikite į atvirą vietą su švaria view of the sky. Keep the device stationary during activation.
Įrenginys neįsijungiaDepleted or expired battery.Check battery expiration date. Contact ACR support for battery replacement.

8. Specifikacijos

9. Kas yra dėžutėje

10. Garantija ir palaikymas

ACR Electronics, Inc. stands behind the quality and reliability of its products. For specific warranty details, service, or technical support, please refer to the official ACR websvetainėje arba susisiekite tiesiogiai su jų klientų aptarnavimo tarnyba.

Aplankykite ACR parduotuvė „Amazon“ platformoje norėdami gauti daugiau informacijos ir produktų pasiūlymų.

11. Svarbi saugos informacija

The ACR ResQLink 400 is a critical safety device. It is subject to regulations by various authorities, including Cospas-Sarsat and the FCC. Always ensure your device is properly registered and maintained according to local and international guidelines. This device is intended for emergency use only. False activation can result in penalties.

Teisinis atsisakymas: Cospas-Sarsat, FCC

Susiję dokumentai - PLB-400

Preview ACR ResQLink PLB įrengimo vadovas, skirtas „Atlas 190 UML“ gelbėjimosi liemenei
Žingsnis po žingsnio instrukcijos, kaip pritvirtinti ACR ResQLink asmeninį lokatoriaus švyturėlį (PLB) prie „Atlas 190 UML“ gelbėjimosi liemenės, užtikrinant saugų ir tinkamą veikimą.
Preview ACR ResQlink AIS tvirtinimo instrukcijos, skirtos „Atlas 190 Hammar“ gelbėjimosi liemenei
Žingsnis po žingsnio vadovas, kaip pritvirtinti ACR ResQlink AIS asmeninį lokatoriaus švyturį (PLB) prie „Mustang Survival Atlas 190 Hammar“ gelbėjimosi liemenės, užtikrinant teisingą ir saugų montavimą avarinėse situacijose.
Preview ACR AISLink MOB prijungimo prie ELITE 190 pripučiamos gelbėjimosi liemenės instrukcijos
Žingsnis po žingsnio vadovas, kaip pritvirtinti ACR AISLink MOB įrenginį prie ELITE 190 pripučiamos gelbėjimosi liemenės, užtikrinant saugų ir tinkamą veikimą.
Preview ACR Sea Shelter™ 4 Mounting Template and Installation Guide
Download the ACR Sea Shelter™ 4 mounting template (Y1-06-0299 A) with detailed dimensions and critical installation cautions for EPIRB safety.
Preview ACR RCL-300A prožektoriaus montavimo ir įrengimo vadovas
Išsamus ACR RCL-300A prožektoriaus sistemos montavimo ir įrengimo vadovas, įskaitant URC-300 pagrindinį valdiklį ir URP-102 valdymo pultą, su išsamiomis laidų prijungimo instrukcijomis ir funkcijomis.
Preview ACR Kelowna dujinės viryklės vadovas: įrengimas, eksploatavimas ir priežiūra
Išsamus ACR Kelowna dujinės viryklės (12H modelis, G20, 20 mbar) naudotojo ir montavimo vadovas, kuriame aptariama sąranka, veikimas, techninės specifikacijos, valymas, priežiūra, trikčių šalinimas, klaidų kodai ir informacija apie garantiją.