1. Įvadas
This manual provides essential information for the safe and efficient operation of your Nilox SAI Premium Line Interactive Sinewave 3000VA Uninterruptible Power Supply (UPS). This device is designed to protect small networks, workstations, computers, and peripherals from power outages and electrical disturbances, ensuring the longevity of connected devices and data integrity.
The UPS features a perfect sine wave output in backup mode, an Automatic Voltage Regulator (AVR) for intelligent voltage management, and an LCD display for real-time monitoring of operational parameters. Please read this manual thoroughly before installation and use.
2. Saugos instrukcijos
Observe the following safety precautions to prevent injury and damage to the UPS or connected equipment:
- Neatidarykite UPS korpuso.asing. Viduje nėra dalių, kurias galėtų aptarnauti vartotojas. Visus techninės priežiūros darbus patikėkite kvalifikuotiems techninės priežiūros darbuotojams.
- Do not install the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Įsitikinkite, kad UPS yra prijungtas prie įžeminto kintamosios srovės maitinimo lizdo.
- Do not connect non-computer related equipment such as medical equipment, life support equipment, or household appliances to the UPS.
- Ensure adequate ventilation around the UPS. Do not block ventilation openings.
- In case of fire, use a dry chemical fire extinguisher. Do not use water.
- Disconnect the UPS from the AC power outlet before cleaning or performing any maintenance.
3. Pakuotės turinys
Carefully unpack the UPS and check the contents. The package should contain:
- Nilox SAI Premium L.I Sinewave 3000VA UPS Unit
- Vartotojo vadovas (šis dokumentas)
- Power cables (may vary by region, typically includes input power cable and output cables)
- USB communication cable (for software monitoring)
Jei kokių nors elementų trūksta arba jie sugadinti, nedelsdami kreipkitės į pardavėją.
4. Produktas baigtasview
4.1 Priekinis skydelis

The front panel features the LCD display and the power button. The LCD provides real-time status updates, including input/output voltage, akumuliatoriaus lygis, apkrovos procentastage, and operational mode. The power button is used to turn the UPS on and off.
4.2 Galinis skydelis

The rear panel includes the AC input, multiple output sockets (IEC C13), a USB communication port, and ventilation fan. There are 6 output sockets in total, providing power to connected devices. The USB port allows connection to a computer for monitoring and management via the ViewMaitinimo programinė įranga.
4.3 LCD ekranas

The LCD display provides comprehensive information about the UPS status:
- Įvesties tomastage: Rodo įeinančio kintamosios srovės garsumątage.
- Išėjimas ttage: Rodo ttage tiekiamas prijungtiems įrenginiams.
- Baterijos lygis: Indicates the current charge level of the internal batteries.
- Apkrovos proctage: Rodo proctage UPS pajėgumų, kuriuos šiuo metu naudoja prijungti įrenginiai.
- AC režimas: Indicates the UPS is operating on utility power.
- Baterijos režimas: Indicates the UPS is operating on battery power (during a power outagir).
- Perkrova: Warning indicator if the connected load exceeds the UPS capacity.
- Žemas Batt: Warning indicator for low battery charge.
- Gedimas: General fault indicator.
5. Sąranka
- Išpakuokite UPS: Remove the UPS from its packaging and inspect it for any shipping damage.
- Vieta: Place the UPS in a cool, dry, and well-ventilated area, away from direct sunlight, heat sources, and excessive dust or moisture. Ensure there is sufficient space around the unit for proper airflow.
- Prijungimas prie kintamosios srovės maitinimo: Connect the UPS's input power cable to a grounded wall outlet. The UPS will begin charging its internal batteries. For optimal performance, allow the UPS to charge for at least 8 hours before connecting any devices.
- Prijunkite įrenginius: Plug your computer, monitor, and other critical peripherals into the output sockets on the rear panel of the UPS. Do not overload the UPS beyond its rated capacity (2100W).
- Pradinis įjungimas: Paspauskite ir kelias sekundes palaikykite nuspaudę priekiniame skydelyje esantį maitinimo mygtuką, kol įsijungs UPS ir užsidegs LCD ekranas.
- Programinės įrangos diegimas (nebūtina): For advanced monitoring and management, connect the UPS to your computer via the USB cable and install the ViewPower software. The software can be downloaded from the official Nilox websvetainę.
6. Naudojimo instrukcijos
6.1 Įjungimas / išjungimas
- Norėdami įjungti: Press and hold the power button on the front panel for approximately 3 seconds until you hear a beep and the LCD display turns on.
- Norėdami išjungti: Press and hold the power button for approximately 3 seconds until the LCD display turns off. Ensure all connected devices are safely shut down before powering off the UPS.
6.2 Understanding UPS Modes
- AC režimas: The UPS is receiving utility power and providing conditioned power to connected devices. The batteries are being charged or maintained.
- Baterijos režimas: Per galios outage arba reikšmingas tūristage fluctuation, the UPS automatically switches to battery power to continue supplying power to connected devices. The LCD will indicate 'Batt. Mode' and an audible alarm may sound.
- AVR Mode: Automatinis tomastage Regulator (AVR) automatically corrects minor voltage fluctuations (sags or surges) without switching to battery power, thus preserving battery life.
6.3 ViewPower Software
The ViewPower software allows you to monitor the UPS status, configure settings, and perform controlled shutdowns of connected systems. Connect the UPS to your computer via the USB port and download the software from the official Nilox website. Refer to the software's help documentation for detailed instructions.
7. Priežiūra
7.1 Akumuliatoriaus keitimas
The Nilox SAI Premium 3000VA UPS uses two 9Ah sealed lead-acid batteries. The typical lifespan of UPS batteries is 3-5 years, depending on usage and environmental conditions. When batteries need replacement, the UPS may indicate a 'Low Batt' or 'Fault' condition more frequently, or the backup time may significantly decrease.
Replacement Battery Code: 17NXBA9A00001 - 17NXBA9A00001T.
Atsargiai: Battery replacement should only be performed by qualified service personnel. Batteries can pose a risk of electrical shock and burns from high short-circuit current. Always disconnect the UPS from the AC power and turn it off before attempting any battery maintenance. Dispose of old batteries properly according to local regulations.
7.2 Valymas
To clean the exterior of the UPS, use a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure the UPS is disconnected from the AC power outlet before cleaning. Keep ventilation openings clear of dust and debris to ensure proper cooling.
8. Problemų sprendimas
This section addresses common issues you might encounter with your UPS. If the problem persists after following these steps, please contact Nilox support.
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| UPS neįsijungia | No AC input power; Low battery; UPS fault | Check AC power connection; Allow UPS to charge for 8 hours; Contact support if fault persists. |
| No power output to devices | UPS in fault mode; Overload; Output circuit breaker tripped | Check LCD for fault indicators; Reduce connected load; Reset output circuit breaker if present. |
| UPS pypsi nuolat arba dažnai | Operating on battery; Low battery; Overload; UPS fault | This is normal during power outages; Allow battery to charge; Reduce connected load; Check LCD for fault. |
| LCD shows 'Overload' | Connected load exceeds UPS capacity | Immediately disconnect non-essential devices to reduce the load. |
| Trumpas atsarginės kopijos laikas | Batteries not fully charged; Batteries nearing end of life; Excessive load | Allow UPS to charge for 8 hours; Consider battery replacement; Reduce connected load. |
9. Techninės specifikacijos
| Funkcija | Specifikacija |
|---|---|
| Modelis | NXGCLISW3K2X9V2 |
| Talpa | 3000 2100 VA / XNUMX W |
| Įvesties tomastage | 230 voltų |
| Išėjimas ttage | 237 Volts (AC Mode) |
| Bangos forma (baterijos režimas) | Gryna sinuso banga |
| Baterijos tipas | Uždaryta švino rūgštis |
| Battery Quantity & Amppakilimas | 2 x 9 Ah |
| Įkrovimo laikas | Approximately 8 hours to 90% capacity |
| Išvesties lizdai | 6 x IEC C13 |
| Ryšio uostas | USB |
| Matmenys (I x P x A) | 49 x 29 x 23 cm |
| Svoris | 13.3 kg |
| Medžiaga | Metalas |
| Formos faktorius | Bokštas |
10. Garantija ir palaikymas
The Nilox SAI Premium L.I Sinewave 3000VA UPS comes with a 3 metų garantija on electronic parts. This warranty includes a convenient pickup and return service, ensuring that any necessary repairs or replacements are handled efficiently without additional cost for collection or delivery of the product.
For technical support, warranty claims, or further assistance, please visit the official Nilox website or contact your local Nilox service center. Ensure you have your product model number (NXGCLISW3K2X9V2) and proof of purchase available when contacting support.