Systemair K 125M Sileo Duct Fan

Instrukcijų vadovas

1. Įvadas

This manual provides detailed instructions for the installation, operation, and maintenance of the Systemair K 125M Sileo duct fan. The K-series fans are designed for efficient air handling in duct systems, featuring robust construction and reliable performance. Please read this manual thoroughly before installation and operation to ensure safe and correct use of the product.

2. Saugos informacija

Montavimo ir eksploatavimo metu visada laikykitės vietinių elektros kodeksų ir saugos taisyklių. Prieš atlikdami bet kokias techninės priežiūros ar montavimo procedūras, atjunkite maitinimą.

  • The fan is equipped with built-in thermal contacts with automatic reset to protect the motor from overheating.
  • The airtight, folded galvanized steel housing (leak rate according to tightness class C, EN 12237:2003) allows for installation in damp rooms and outdoor areas.
  • The motor has a protection class of IP44.
  • Užtikrinkite tinkamą įžeminimą.
  • Nenaudokite ventiliatoriaus, jei kuri nors jo dalis yra pažeista.

3. Produkto ypatybės

The Systemair K 125M Sileo duct fan offers the following key features:

  • Speed-Controllable: Can be controlled using a stepless thyristor or a 5-step transformer.
  • Integruota šiluminė apsauga: Built-in thermal contacts with automatic reset for motor safety.
  • Lankstus montavimas: Installation is possible in any mounting position.
  • Outdoor and Damp Room Use: Tinka lauke ir damp environments due to its airtight housing and IP44 motor protection.
  • Reliable and Maintenance-Free: Designed for dependable operation with minimal maintenance requirements.
  • Efektyvus dizainas: Features backward-curved impeller blades and external rotor motors for optimal performance.
  • Lengvas montavimas: Includes a mounting bracket for straightforward installation and removal.

4. Techninės specifikacijos

ParametrasVertė
ModelisK 125M Sileo
ttage230 V
Dažnis50 Hz
Fazė1~
Electrical Power Consumption (P1)28.2W
Dabartinė0.164A
Max. Volume Flow187 m³/val
Greitis2491 1/min
Svoris2.3 kg
Max. Medium Temperature70°C
Max. Medium Temperature (Speed Controlled)70°C
Sound Pressure Level at 3m (20m³ Sabin)34.2dB(A)
Izoliacijos klasėB
Protection Class, MotorIP44
Jungties skersmuo125 mm
Energy Class (Basic Unit)F
Energy Class (Basic Unit Option)C
ErP ReadyErP 2018
GamintojasSystemair
ASINB07ZP91RP2
Gamintojo nuoroda103573
Table showing maximum efficiency and operating data for the Systemair K 125M Sileo fan

Figure 4.1: Maximum Efficiency and Operating Data Table. This table provides detailed performance metrics including airflow, static pressure, power consumption, and sound levels at various frequencies.

Energy efficiency labels for Systemair K125M Sileo fan, showing F and C ratings

Figure 4.2: Energy Efficiency Labels. Displays the energy class ratings for the basic unit (F) and an optional configuration (C), along with sound power level (29 dB) and airflow (90 m³/h).

5. Diegimas ir sąranka

The K-series fans are designed for easy duct mounting. Ensure the installation location is suitable and allows for proper airflow and access for maintenance.

Systemair K 125M Sileo duct fan, a cylindrical fan with a control box on top

Figure 5.1: Systemair K 125M Sileo Duct Fan. This image shows the main product view of the cylindrical duct fan with its integrated control box.

5.1 Montavimas

  • The fan comes with a mounting bracket to facilitate easy installation and removal.
  • All K-fans feature duct connections at least 25 mm long, compliant with EN 1506:1997, for secure attachment to ductwork.
  • For vibration-free connection to the duct system, consider using FK connecting sleeves (available as accessories).
  • The fan can be installed in any mounting position (horizontal, vertical, etc.).
Technical drawing showing dimensions of the Systemair K 125M Sileo fan

Figure 5.2: Dimensions Diagram. This technical drawing illustrates the various dimensions (A, B, C, D, E, F) of the fan, crucial for planning installation space and duct connections.

5.2 Elektros prijungimas

Connect the fan to a 230V, 50Hz, single-phase power supply. Ensure all wiring is done by a qualified electrician and complies with local regulations. The fan is equipped with an external rotor motor.

6. Operacija

The Systemair K 125M Sileo fan is designed for continuous operation within its specified parameters.

6.1 Greičio valdymas

The fan's speed can be controlled to adjust airflow as needed. This can be achieved using:

  • A stepless thyristor controller.
  • A 5-step transformer.

Refer to the performance diagrams to understand the fan's behavior at different operating points.

Performance curves for the Systemair K 125M Sileo fan showing static pressure and power versus volume flow

Figure 6.1: Performance Diagrams. These graphs illustrate the fan's static pressure (P stat.) and power consumption (P) in relation to the volume flow (Q), providing insight into its operational characteristics.

7. Priežiūra

The Systemair K 125M Sileo fan is designed to be reliable and largely maintenance-free. However, periodic checks can help ensure optimal performance and longevity.

  • Valymas: Periodically inspect the impeller and housing for dust and debris accumulation. Clean gently with a soft brush or cloth. Ensure power is disconnected before cleaning.
  • Patikra: Check electrical connections for tightness and signs of wear.
  • Guoliai: The fan's motor bearings are typically sealed and do not require lubrication.

8. Problemų sprendimas

If you encounter issues with your Systemair K 125M Sileo fan, consider the following common troubleshooting steps:

  • Fan not starting: Check the power supply, circuit breaker, and electrical connections. Ensure the thermal contacts have not tripped (they reset automatically).
  • Sumažėjęs oro srautas: Inspect ducts for obstructions or leaks. Check if the fan speed controller is set correctly.
  • Neįprastas triukšmas arba vibracija: Ensure the fan is securely mounted. Check for any foreign objects in the impeller or housing. Verify that the FK connecting sleeves are properly installed if used.
  • Perkaitimas: Ensure adequate ventilation around the fan. Check for obstructions that might restrict airflow. The built-in thermal contacts should protect the motor.

If problems persist after performing these checks, contact qualified service personnel or Systemair support.

9. Garantija ir palaikymas

For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your Systemair dealer. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or service inquiries, please contact your local Systemair representative or the seller from whom you purchased the product. Provide the model number (K 125M Sileo) and serial number (if applicable) when seeking support.

Susiję dokumentai - K 125M Sileo

Preview „Systemair K 315 L SILEO“ išcentrinis kanalinis ventiliatorius – techninės specifikacijos ir matmenys
Išsamios „Systemair K 315 L SILEO“ išcentrinio kanalinio ventiliatoriaus techninės specifikacijos, matmenys, laidų schemos ir priedai. Įskaitant našumo duomenis, triukšmo lygius ir montavimo informaciją.
Preview „Systemair RVK“ apvalus ortakinis ventiliatorius: montavimo ir naudojimo instrukcijos
Šiame vadove išsamiai aprašomas „Systemair RVK“ apvalių ortakių ventiliatorių montavimas, eksploatavimas ir priežiūra. Jame aptariami saugos protokolai, elektros jungtys, paleidimas, trikčių šalinimas ir geriausia praktika, siekiant optimalaus vėdinimo sistemų veikimo.
Preview Systemair DXRE/DXRE-D Duct Cooler Installation and Maintenance Manual
This document provides comprehensive installation, mounting, and cleaning instructions for the Systemair DXRE/DXRE-D duct cooler, designed for central cooling of ventilation air and compatible with outdoor units for heating and cooling.
Preview „Systemair“ interneto prieigos modulio (IAM) naudotojo vadovas
Išsamus „Systemair“ interneto prieigos modulio (IAM), skirto SAVE gyvenamųjų patalpų vėdinimo įrenginiams, naudotojo vadovas, kuriame aprašomas įrengimas, konfigūravimas, tinklo ryšys, „Modbus TCP“ režimas ir mobiliosios programėlės integravimas.
Preview „Systemair SAVE VTR 300/B“ techninės priežiūros ir priedų montavimo vadovas
Išsamus „Systemair SAVE VTR 300/B“ šilumos atgavimo vėdinimo įrenginio įrengimo, konfigūravimo ir priežiūros vadovas, apimantis saugą, techninius duomenis, veikimą ir priedus.
Preview „Systemair SAVE VTR 150/B“ montavimo vadovas
Comprehensive installation manual for the Systemair SAVE VTR 150/B heat recovery ventilation unit. Covers general information, technical specifications, dimensions, mounting procedures for various kitchen hoods, electrical connections, system checks, commissioning, and disposal guidelines.