Danfoss 134U2978

„Danfoss FC280“ keitiklio pavaros naudojimo instrukcija

Modelis: 134U2978

1. Įvadas

This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Danfoss FC280 Inverter Drive, model 134U2978. The FC280 is a versatile frequency converter designed for precise motor control in various industrial applications.

The Danfoss FC280 Inverter Drive is engineered to deliver reliable performance for controlling 3-phase AC motors, offering advanced features for energy efficiency and process optimization.

2. Saugos informacija

WARNING: Read all safety instructions carefully before installation, operation, or maintenance. Failure to comply may result in serious injury or death, and/or equipment damage.

3. Produkto ypatybės

The Danfoss FC280 Inverter Drive (Model 134U2978) offers a range of features designed for robust performance and control:

Danfoss FC280 Inverter Drive

3.1 pav.: priekis view of the Danfoss FC280 Inverter Drive, showing the control panel and VLT Midi Drive branding.

4. Montavimas

4.1 Montavimas

The FC280 drive should be mounted vertically on a flat, stable surface in an environment that meets the specified operating conditions (temperature, humidity, ventilation). Ensure adequate clearance around the unit for proper airflow and heat dissipation.

4.2 Laidai

All wiring must be performed by a qualified electrician in accordance with local and national electrical codes. Incorrect wiring can cause damage to the drive, motor, or pose a safety hazard.

  1. Maitinimo laidai: Connect the 3-phase 400V AC input power to the L1, L2, L3 terminals. Ensure correct phase sequence.
  2. Variklio laidai: Connect the motor leads to the U, V, W output terminals.
  3. Įžeminimas: Connect the protective earth (PE) terminal of the drive to a reliable ground point.
  4. Valdymo laidai: Connect control signals (e.g., start/stop, speed reference) to the appropriate control terminals as per your application requirements. Refer to the detailed wiring diagrams in the full product manual for specific terminal assignments.

5. Pradinė sąranka ir konfigūracija

After successful installation and wiring, the drive requires initial setup. The FC280 features a user-friendly control panel for parameter adjustment.

  1. Maitinimas: Apply main power to the drive. The display on the control panel should illuminate.
  2. Basic Parameter Setting:
    • Naršykite meniu naudodami rodyklių klavišus.
    • Set motor nominal voltage (pvz., 400 V).
    • Set motor nominal current.
    • Set motor nominal frequency (e.g., 50Hz or 60Hz).
    • Set motor nominal speed.
    • Configure acceleration and deceleration ramps.
  3. Motor Auto-Tune (Optional but Recommended): For optimal performance, perform a motor auto-tune function if available in the drive's menu. This process measures motor parameters and optimizes the drive's control algorithms.
  4. Išsaugoti nustatymus: Ensure all configured parameters are saved before exiting the setup menu.

6. Naudojimo instrukcijos

The Danfoss FC280 Inverter Drive can be operated via its local control panel or external control signals.

6.1 Local Operation (Control Panel)

6.2 Nuotolinis valdymas

For remote control, the drive can accept signals from external sources such as PLCs, potentiometers, or other control devices connected to its control terminals. Refer to the detailed wiring and parameter settings for remote control in the comprehensive product manual.

7. Priežiūra

Regular maintenance ensures the longevity and reliable operation of your Danfoss FC280 Inverter Drive. Always disconnect power before performing any maintenance.

8. Problemų sprendimas

This section provides general guidance for common issues. For detailed fault codes and advanced troubleshooting, refer to the complete Danfoss FC280 manual.

ProblemaGalima priežastisSprendimas
Drive does not power on.Nėra įėjimo galios; perdegęs saugiklis; neteisingas laidų sujungimas.Patikrinkite maitinimo šaltinį; Apžiūrėkite saugiklius; Patikrinkite laidų jungtis.
Variklis neveikia.Drive in fault state; Incorrect parameters; No start command.Check drive display for fault codes; Verify motor parameters; Ensure start command is active.
Overcurrent fault.Motor overload; Short circuit in motor/cables; Incorrect motor parameters.Reduce load; Check motor and cables for damage; Verify motor parameters.
Overvoltage kaltė.Didelis įėjimo tūristage; Regenerative braking without braking resistor.Patikrinkite įvesties tūrįtage; Consider adding a braking resistor if applicable.

9. Techninės specifikacijos

ParametrasVertė
Modelio numeris134U2978
Gaminių serijaFC280 (VLT Midi Drive)
Išėjimo Dažnių diapazonas0–20 000 Hz
Išėjimo galia0.55 kW
Įvesties fazė3 fazių
Įvesties tomastage400 V
Gaminio matmenys (I x P x A)16 x 11 x 16 colio
Svoris6.55 svaro
GamintojasDANFOSS
ASINB0828YM3DF

10. Garantija ir palaikymas

For detailed warranty information, please refer to the official Danfoss warranty statement provided with your product or visit the official Danfoss websvetainėje. Garantijos sąlygos gali skirtis priklausomai nuo regiono ir pirkimo datos.

For technical support, service, or spare parts, please contact your authorized Danfoss distributor or visit the Danfoss support portal. When contacting support, please have your product model number (134U2978) and serial number readily available.

Official Danfoss Websvetainė: www.danfoss.com

Susiję dokumentai - 134U2978

Preview „Danfoss CDS203“ pavara: įrengimo ir naudojimo instrukcijos
Išsamus „Danfoss CDS203“ kintamo greičio pavaros įrengimo ir naudojimo vadovas, apimantis saugos informaciją, gaminio pristatymą, mechaninį ir elektrinį įrengimą, sąranką, veikimą, diagnostiką ir techninius duomenis.
Preview „Danfoss Ally™“ išmaniosios šildymo sistemos naudotojo vadovas
Comprehensive user guide for the Danfoss Ally™ smart heating system, covering installation, features, technical specifications, and troubleshooting for the Gateway, Radiator Thermostat, Room Sensor, Boiler Relay, Protect RA, Power Module, and Icon™/Icon2™ thermostats.
Preview Danfoss 4SP MFC 0.75-45T-3 Wiring Diagram and Technical Specification
Detailed wiring diagram and technical information for the Danfoss 4SP MFC 0.75-45T-3 motor drive system, including inverter connections, toroid configurations, and control signal routing.
Preview VLT® Micro Drive FC 51 naudojimo vadovas
Išsamus „Danfoss VLT® Micro Drive FC 51“ naudojimo vadovas, apimantis įrengimą, laidus, parametrų nustatymus ir veikimą. Apima technines specifikacijas ir saugos informaciją, skirtą pramoniniam naudojimui.
Preview Danfoss iC2-Micro: Compact, Flexible, and Convenient AC Drive Selection Guide
Explore the Danfoss iC2-Micro AC drive, a versatile solution offering compact design, high performance, and user-friendly operation. Learn about its features, applications, digital tools like MyDrive Suite, and life cycle services for industrial use.
Preview „Danfoss iC7-Automation“ keitiklio montavimo vadovas
Guida completa all'installazione degli inverter Danfoss iC7-Automation raffreddati ad aria in quadro. Copre installazione meccanica, elettrica, cablaggio, messa a terra, specifiche tecniche, e procedure di messa in funzione per garantire un funzionamento sicuro ed efficiente.