Patlite LR7-02WTNK

Patlite LR7-02WTNK Base Unit 24VDC Series LED Signal Tower Instruction Manual

Model: LR7-02WTNK | Brand: Patlite

1. Įvadas

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Patlite LR7-02WTNK Base Unit. The LR7-02WTNK is a 24VDC base module designed for Patlite LR7 series LED signal towers, featuring a 70mm diameter, direct mount capability, and terminal block connections, with an IP65 ingress protection rating.

Prieš bandydami bet kokį įrengimą ar naudojimą, atidžiai perskaitykite šį vadovą, kad užtikrintumėte tinkamą veikimą ir saugą.

2. Saugos informacija

Always observe the following safety precautions to prevent injury to personnel and damage to the equipment.

  • Elektros sauga: Ensure the power supply is disconnected before performing any installation, wiring, or maintenance. This unit operates on 24VDC. Verify the power source matches the specified voltage.
  • Kvalifikuotas personalas: Installation and wiring should only be performed by qualified and experienced personnel.
  • Aplinkos sąlygos: The unit is rated IP65, indicating protection against dust ingress and low-pressure water jets. Do not submerge the unit or expose it to high-pressure water.
  • Montavimas: Securely mount the base unit to a stable surface to prevent accidental detachment or damage.
  • Modifikacijos: Do not modify or disassemble the unit. Unauthorized modifications can lead to malfunction, electric shock, or fire.

3. Sąranka ir diegimas

The Patlite LR7-02WTNK base unit is designed for direct mounting and features a terminal block for electrical connections.

  1. Išpakavimas: Carefully remove the base unit from its packaging. Inspect for any visible damage during transit.
  2. Montavimo vieta: Select a suitable, stable, and flat surface for direct mounting. Ensure adequate space for connecting other LR7 series modules if applicable.
  3. Mounting the Base Unit: Secure the base unit using appropriate fasteners through the designated mounting holes. Ensure the unit is firmly attached and stable.
  4. Laidai:
    • Ensure the 24VDC power supply is disconnected.
    • Access the terminal block on the base unit.
    • Connect the 24VDC power supply wires to the appropriate terminals, observing polarity (+ and -).
    • Įsitikinkite, kad visos jungtys yra saugios ir tinkamai izoliuotos.
  5. Module Assembly (if applicable): If assembling with other LR7 series LED modules, align the modules and twist to lock them securely onto the base unit.
Patlite LR7-02WTNK Base Unit with label showing model number and electrical specifications.

Figure 3.1: Patlite LR7-02WTNK Base Unit. This image displays the Patlite LR7-02WTNK base unit, a black cylindrical component. The label on the side indicates 'MODEL LR7-02WTN', 'VOLT 24V DC Class2', 'AMP Max. 0.25A', and 'WATT 6.6W'. This unit is designed for direct mounting and features a terminal block for electrical connections.

4. Naudojimo instrukcijos

The LR7-02WTNK functions as the base for a modular signal tower system. Its operation is primarily dependent on the connected LED modules and the control system.

  • Maitinimas: Once the base unit is correctly wired and any additional modules are assembled, apply 24VDC power to the unit.
  • Funkcionalumas: The base unit provides the electrical connection and mechanical foundation for the signal tower. The specific signaling functions (e.g., light patterns, audible alarms) are controlled by the connected modules and external control signals. Refer to the manuals for the specific LR7 series LED modules for detailed operational instructions.
  • Išjungti: To power off the unit, disconnect the 24VDC power supply.

5. Priežiūra

The Patlite LR7-02WTNK base unit is designed for minimal maintenance. Regular inspection and cleaning will help ensure its longevity and reliable operation.

  • Valymas:
    • Prieš valydami atjunkite maitinimą.
    • Nuvalykite įrenginio išorę minkšta, damp audinys.
    • Do not use abrasive cleaners, solvents, or strong chemicals, as these may damage the housing.
  • Patikra: Periodiškai apžiūrėkite įrenginį, ar nėra:
    • Loose connections at the terminal block.
    • Physical damage to the housing or mounting points.
    • Accumulation of dust or debris, especially around connections.
  • Remontas: There are no user-serviceable parts inside the LR7-02WTNK base unit. If the unit is damaged or malfunctions, contact Patlite customer support or a qualified service technician.

6. Problemų sprendimas

If the Patlite LR7-02WTNK base unit or the connected signal tower is not functioning as expected, perform the following basic checks:

  • No Power/No Indication:
    • Verify that the 24VDC power supply is active and providing the correct voltage.
    • Check all wiring connections at the terminal block for looseness or incorrect polarity.
    • Ensure the power supply capacity is sufficient for the entire signal tower assembly.
  • Operacija su pertraukomis:
    • Patikrinkite, ar nėra atsilaisvinusių laidų jungčių ar pažeistų kabelių.
    • Ensure the unit is securely mounted and not subject to excessive vibration.
  • Fizinė žala: If the unit shows signs of physical damage (cracks, deformation), it may need replacement. Do not attempt to repair damaged components.

If the issue persists after performing these checks, contact Patlite customer support for further assistance.

7. Specifikacijos

AtributasVertė
Modelio numerisLR7-02WTNK
Prekės ženklasPatlite
ttage24V DC Class2
Maksimali srovė0.25A
Maksimalus energijos suvartojimas6.6W
Skersmuo70 mm
Apsaugos nuo patekimo (IP) įvertinimasIP65
Montavimo tipasTiesioginis montavimas
Ryšio tipasTerminalo blokas
MedžiagaVaris
Pakuotės matmenys5.71 x 3.74 x 3.66 colio
Prekės svoris7.05 uncijos
Pasiekiama pirmoji data16 m. rugsėjo 2022 d

8. Garantija ir palaikymas

For information regarding product warranty, please refer to the official Patlite website or the warranty documentation provided with your purchase. For technical support, spare parts, or service inquiries, please contact Patlite customer support directly.

You can typically find contact information on the official Patlite websvetainė: www.patlite.com

Susiję dokumentai - LR7-02WTNK

Preview PATLITE Signal Tower Installation Manual
Official installation manual for PATLITE Signal Towers (LR4, LR5, LR7 series), providing guidance on model confirmation, parts identification, installation steps, technical specifications, and troubleshooting. Includes safety warnings.
Preview PATLITE signalinio bokšto LR serijos įrengimo ir naudojimo instrukcija
Išsamus PATLITE signalinių bokštų LR serijos vadovas, apimantis įrengimą, veikimą, saugą, laidus ir technines specifikacijas. Svarbi literatūra tinkamam įrengimui ir naudojimui.
Preview PATLITE LR Series Signal Towers: Comprehensive Datasheet and Product Guide
Detailed information on PATLITE's LR Series LED signal towers, including features, specifications, pre-assembled and modular models, optional parts, wiring diagrams, and compatibility charts.
Preview PATLITE Signal Tower LR4/LR5/LR6/LR7: Complete Operation Manual
Comprehensive operation manual for PATLITE Signal Towers (Models LR4, LR5, LR6, LR7), covering installation, wiring, specifications, troubleshooting, and maintenance. Ensure safe and correct use of your PATLITE signal tower.
Preview PATLITE pramoniniai LED signaliniai bokštai ir apšvietimo sprendimai
Peržiūrėkite platų PATLITE LED signalinių bokštų, šviesos juostų ir švyturėlių asortimentą iš AutomationDirect.com, kuriame rasite išsamias specifikacijas, gaminių savybes ir taikymo gaires pramoninei aplinkai.
Preview PATLITE Signal Tower LR4/LR5/LR6/LR7 Series: Complete Operation Manual
Comprehensive operation manual for PATLITE LR4, LR5, LR6, and LR7 series signal towers. Covers installation, operation, maintenance, model configuration, wiring, safety, troubleshooting, and specifications for industrial signaling applications.