Simplex 4006-9101

Simplex 4006-9101 Standard Fire Alarm Control Panel User Manual

Model: 4006-9101 (Item Model Number: 400 9101)

Įvadas

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Simplex 4006-9101 Standard Fire Alarm Control Panel. Designed for areas requiring five to ten initiating zones, this panel offers flexible initiating circuit monitoring, extensive programmable control capabilities, and an LCD for annunciated circuit-specific 20-character custom labels. Proper understanding and adherence to these instructions are crucial for the safe and effective functioning of the fire alarm system.

Produktas baigtasview

Priekyje view of the Simplex 4006-9101 Fire Alarm Control Panel, a red rectangular unit with a central display and control buttons.

The Simplex 4006-9101 is a robust fire alarm control panel housed in a distinctive red enclosure. It features a central display and an array of control buttons for system management. This panel is designed for professional hard-wired installations and includes essential components for a comprehensive fire safety system.

Pagrindinės funkcijos:

  • 5 Class B Initiating Device Circuits (IDCs)
  • 2 Class B/Class A Notification Appliance Circuits (NACs)
  • 3 Ampere power supply with integrated battery charger
  • On-board Digital Alarm Communicator Transmitter (DACT)
  • Operates on 120/240 VAC, 50/60 Hz (auto-selecting)
  • LCD annunciated circuit-specific 20 character custom labels

Interjeras view of the Simplex 4006-9101 Fire Alarm Control Panel with the door open, revealing the main circuit board, wiring terminals, and internal documentation.

The interior of the control panel is meticulously organized, featuring the main circuit board, clearly labeled wiring terminals for various circuits (IDCs, NACs, power), and internal documentation including emergency operation procedures and wiring diagrams. This design facilitates professional installation and maintenance.

Sąranka ir diegimas

The Simplex 4006-9101 Fire Alarm Control Panel requires professional hard-wired installation. It is crucial that installation is performed by qualified personnel in accordance with all local and national electrical and fire safety codes.

Įtraukti komponentai

Laidai ir jungtys

Close-up of the internal wiring terminals and circuit board of the Simplex 4006-9101 Fire Alarm Control Panel, showing IDC, NAC, and power connections.

Refer to the detailed wiring diagrams provided within the panel's internal documentation and the separate installation guide for precise connection instructions. Ensure all power connections (120/240 VAC) are made correctly and safely. Connect initiating devices (smoke detectors, pull stations) to the IDC terminals and notification appliances (horns, strobes) to the NAC terminals.

A wiring harness with multiple colored wires and connectors, typically used for internal connections within the control panel.

The provided wiring harness facilitates specific internal connections. Ensure these are securely attached according to the installation diagrams.

Maitinimo šaltinis ir baterija

The panel includes a 3 Ampere power supply with a battery charger. Connect the primary AC power source (120/240 VAC, 50/60 Hz) to the designated terminals. Install backup batteries (not typically included with the panel, refer to specifications for type and capacity) to ensure continuous operation during power outages.

Valdymo skydo valdymas

The Simplex 4006-9101 features an intuitive control interface with an LCD display and tactile buttons. Access to certain functions may require the use of the provided key.

Interior of the Simplex 4006-9101 Fire Alarm Control Panel door, showing emergency operation procedures and a diagram of the control panel buttons.

The inside of the panel door provides a quick reference guide for emergency operation procedures and a layout of the control buttons. This includes instructions on how to acknowledge alarms, silence signals, and reset the system.

Pagrindinės operacijos

A small brass key with the letter 'B' stamped on it, next to a black cylindrical keyhole cover.

The provided key is used to access the control panel's internal components and may be required to enable certain operational modes or to reset the system after specific events. Keep this key in a secure, accessible location.

Priežiūra

Regular maintenance is essential to ensure the reliable operation of your Simplex 4006-9101 Fire Alarm Control Panel. All maintenance procedures should be performed by qualified fire alarm technicians.

Eiliniai patikrinimai

Valymas

Keep the exterior of the control panel clean using a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure ventilation openings are free from dust and debris.

Trikčių šalinimas

This section provides guidance for common issues. For complex problems or persistent trouble conditions, contact a qualified fire alarm technician.

ProblemaGalima priežastisSprendimas
Panel displays "TROUBLE"Open circuit, ground fault, or device malfunction.Check the LCD for specific trouble messages. Inspect wiring for damage. Contact technician for diagnosis.
Alarm sounds continuously after resetAlarm condition still present or device not reset.Ensure the cause of the alarm (e.g., smoke) is cleared. Manually reset any activated devices (e.g., pull station).
No power to panelAC power loss or battery issue.Check AC power supply. Verify battery connections and charge. Replace batteries if necessary.
Klaviatūra nereaguojaLaikinas programinės įrangos triktis arba aparatinės įrangos problema.Try a system reset (if possible). If problem persists, contact technician.

Specifikacijos

AtributasDetalė
GamintojasPaprastas
Dalies numeris4006-9101
Prekės modelio numeris400 9101
SpalvaRaudona
Maitinimo šaltinisBattery Powered (with AC input)
Diegimo būdasProfesionalus, laidinis
Prekės pakuotės kiekis1
Įtraukti komponentaiSmoke Detector, Pull Station, Horn/Strobe (as compatible devices)
Ryšio technologijaLaidinis
Įspėjimo tipasMotion Only (Note: This might be a generic category, actual alerts are fire/trouble)
Kontrolės metodasTouch (via keypad)
Vienetų skaičius1.0 Skaičius
Initiating Device Circuits (IDCs)5 B klasė
Notification Appliance Circuits (NAC)2 Class B/Class A
Maitinimo šaltinis3 A with battery charger
ttage120/240 VAC, 50/60 Hz (autoselect)
Digital Alarm Communicator Transmitter (DACT)Laive

Informacija apie garantiją

The Simplex 4006-9101 Standard Fire Alarm Control Panel comes with a 12 mėnesių garantija from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For warranty claims or detailed terms and conditions, please refer to the official Simplex warranty documentation or contact Simplex customer support.

Palaikymas ir kontaktai

For technical assistance, service, or further information regarding your Simplex 4006-9101 Fire Alarm Control Panel, please contact Simplex customer support or a certified fire alarm system professional.

Susiję dokumentai - 4006-9101

Preview Simplex 4006 Series LifeAlarm Fire Alarm Control Panels: Features, Specifications, and Operation
Comprehensive guide to the Simplex 4006 Series LifeAlarm Fire Alarm Control Panels, detailing features, specifications, product selection, operational modes, and installation references.
Preview Simplex 4008/4006-9801 Expansion Power Supply (EPS) Installation Guide
Installation instructions for the Simplex 4008/4006-9801 Expansion Power Supply (EPS), detailing mounting, panel interconnections, NAC wiring, auxiliary power, and NAC ratings for fire alarm systems.
Preview „Simplex 4005“ serijos „LifeAlarm“ priešgaisrinės signalizacijos valdymo pultai – techninis vadovas
Susipažinkite su „Simplex 4005“ serijos „LifeAlarm“ priešgaisrinės signalizacijos valdymo pultų savybėmis, specifikacijomis ir pritaikymu. Šiame dokumente pateikiama išsami informacija sistemų integratoriams ir įrenginių valdytojams.
Preview „Simplex 4907-9101 NEWS™“ imtuvas: įrengimo, programavimo ir naudojimo instrukcijos
This manual provides comprehensive installation, programming, and operating instructions for the Simplex 4907-9101 NEWS™ Receiver. This system is a public emergency warning receiver compatible with the 4100U Fire Alarm Control Panel, designed for alerting building complexes of emergency situations via EAS and SAME messages.
Preview „Simplex 4090-9101“, „4090-9106“ monitoriaus ZAM įrengimo instrukcijos
„Simplex 4090-9101“ ir „4090-9106“ stebėjimo zonos adapterio modulių (ZAM) įrengimo instrukcijos. Apima mechaninį įrengimą, adreso nustatymą DIP jungikliais ir elektros jungtis, skirtas IDNet ir MAPNET II sistemoms.
Preview Simplex 4004 Fire Alarm Control Panel: Installation and Operation Instructions
Comprehensive guide for installing, operating, and programming the Simplex 4004 Fire Alarm Control Panel (FACP), including system overview, requirements, wiring, module descriptions, and troubleshooting.