Gre SCGPHP100

Gre SCGPHP100 Salt Electrolysis System

Vartotojo vadovas

1. Produktas baigtasview

The Gre SCGPHP100 is an advanced pool water treatment system that combines salt electrolysis for disinfection, an integrated pH controller, and a dosing pump. This system eliminates the need for traditional chemical chlorine, providing a more natural and comfortable swimming experience.

Gre SCGPHP100 Salt Electrolysis System with pH Controller and Dosing Pump

Figure 1: Complete Gre SCGPHP100 system including the main control unit, electrolysis cell, pH probe, and calibration solutions.

Pagrindinės funkcijos:

  • Integrated Disinfection: Salt electrolysis system produces natural chlorine from salt, eliminating the need for chemical chlorine.
  • pH Control: Built-in pH controller with an automatic dosing pump maintains optimal pH levels in your pool water.
  • Didelė talpa: Capable of producing 21 g/h of chlorine, suitable for pools up to 100 m³.
  • Padidintas komfortas: Natural chlorine production reduces odors and eye irritation commonly associated with chemical chlorine.
  • Chemical-Free Handling: Minimizes the storage and handling of hazardous pool chemicals.

2. Saugos informacija

Read all instructions carefully before installation and operation. Failure to follow these instructions may result in injury or damage to the equipment.

  • Prieš atlikdami bet kokią techninę priežiūrą ar remontą, visada atjunkite maitinimą.
  • Užtikrinkite tinkamą elektros įžeminimą.
  • Saugokite įrenginį nuo tiesioginių saulės spindulių ir ekstremalių temperatūrų.
  • Nenaudokite sistemos, jei kuri nors dalis yra pažeista.
  • Užtikrinkite tinkamą ventiliaciją aplink įrenginį.
  • Laikyti vaikams nepasiekiamoje vietoje.
  • Consult a qualified electrician or pool professional for installation if unsure.

3. Diegimas ir sąranka

3.1. Išpakavimas ir patikrinimas

Atsargiai išimkite visus komponentus iš pakuotės. Patikrinkite, ar visos dalys yra ir nepažeistos. Visą inventorių rasite pakavimo sąraše.

3.2. System Placement

Install the main control unit in a dry, well-ventilated area, protected from direct weather exposure. The unit should be mounted vertically on a wall or sturdy surface near the pool's filtration system.

Priekyje view of Gre SCGPHP100 main control unit

Figure 2: Main control unit with pH display and control buttons.

3.3. Santechnikos jungtys

  1. Electrolysis Cell: Install the electrolysis cell (salt cell) in the return line of your pool's filtration system, after the filter and heater (if applicable). Ensure the flow direction arrow on the cell matches the water flow.
  2. Gre SCGPHP100 electrolysis cell

    Figure 3: The transparent electrolysis cell where chlorine is generated.

  3. pH zondas: Install the pH probe in a dedicated probe holder or a suitable location in the plumbing line where water flow is consistent.
  4. Gre SCGPHP100 pH probe

    Figure 4: The pH probe, used to measure the pool water's pH level.

  5. Dozavimo siurblys: Connect the suction tube of the dosing pump to a container of pH-reducing liquid (e.g., liquid acid). Connect the injection tube to an injection point in the pool's return line, typically after the electrolysis cell.
  6. Close-up of the dosing pump on the Gre SCGPHP100 unit

    Figure 5: Detail of the peristaltic dosing pump for pH correction.

3.4. Elektros jungtys

Connect the main control unit to a dedicated, grounded electrical outlet. Ensure all connections are secure and comply with local electrical codes. Connect the electrolysis cell and pH probe cables to their respective ports on the main unit.

3.5. Initial Pool Water Preparation

  • Įpilkite druskos: Add pool-grade salt to your pool water to achieve a concentration of 4 g/l (grams per liter). Circulate the water until the salt is fully dissolved.
  • Balance Water Chemistry: Before starting the system, ensure your pool's alkalinity and calcium hardness are within recommended ranges.

4. Naudojimo instrukcijos

4.1. Įjungimas

Once all connections are made and the pool water is prepared, switch on the power to the unit. The display will illuminate, showing the current pH reading.

4.2. pH Probe Calibration

For accurate pH readings, calibrate the pH probe regularly (e.g., monthly or after long periods of inactivity). Use the provided calibration solutions (pH 7.0 and pH 4.0).

pH calibration solutions for Gre SCGPHP100

Figure 6: pH 7.0 and pH 4.0 calibration solutions.

  1. Rinse the pH probe with distilled water.
  2. Immerse the probe in the pH 7.0 solution. Press the "CAL" button and follow the on-screen prompts until calibration is complete.
  3. Rinse the probe again.
  4. Immerse the probe in the pH 4.0 solution. Press the "CAL" button and follow the on-screen prompts until calibration is complete.
  5. Return the probe to its holder in the plumbing line.

4.3. Setting pH Target

Use the "SET" button to adjust the desired pH target level (typically between 7.2 and 7.6 for pools). The system will automatically dose pH-reducing liquid to maintain this level.

4.4. Adjusting Chlorine Production

The unit features a "Power selector" to adjust the chlorine production level (e.g., 0%, 50%, 75%, 100%). Start with a moderate setting and adjust based on pool usage and chlorine demand. The "SALT" indicator will illuminate if salt levels are too low.

5. Priežiūra

5.1. Electrolysis Cell Cleaning

The electrolysis cell may accumulate scale deposits over time, especially in hard water areas. Inspect the cell regularly (e.g., monthly) and clean as needed.

Kampuotas view of the Gre SCGPHP100 electrolysis cell

7 pav.: Kampinis view of the electrolysis cell, showing the internal plates.

  1. Turn off the system and close all valves to isolate the cell.
  2. Remove the cell from the plumbing.
  3. Soak the cell in a diluted acid solution (e.g., 1 part muriatic acid to 4 parts water) for no more than 15 minutes, or until deposits dissolve. Dėvėkite atitinkamą saugos įrangą.
  4. Rinse thoroughly with fresh water before reinstallation.

5.2. pH Probe Maintenance

  • Keep the pH probe tip moist when not in use, preferably in a storage solution or pH 7.0 buffer.
  • Clean the probe tip gently with a soft brush if deposits are visible.
  • Recalibrate the probe regularly as described in Section 4.2.

5.3. Salt Level Monitoring

Regularly check your pool's salt concentration using a salt test kit. Maintain a level of 4 g/l for optimal system performance. Add salt as needed.

6. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Nėra chloro gamybosLow salt level; Dirty electrolysis cell; Low water flow; System off.Check salt level and add salt; Clean electrolysis cell; Ensure pump is running and filter is clean; Turn system on.
Incorrect pH ReadingpH probe needs calibration; Dirty pH probe; pH probe faulty.Calibrate pH probe (Section 4.2); Clean pH probe; Replace pH probe.
pH Not AdjustingDosing pump not working; Empty pH-reducing liquid container; Clogged injection line.Check dosing pump power/operation; Refill liquid container; Clear injection line.
"SALT" Indicator OnPer žemas druskos kiekis.Add pool-grade salt to achieve 4 g/l concentration.

7. Specifikacijos

FunkcijaDetalė
Modelio numerisSCGPHP100
Prekės ženklasGre
Chlorine Production Capacity21 g/val
Rekomenduojamas baseino tūrisIki 100 m³
Required Salt Concentration4 g/l
Gaminio matmenys (I x P x A)19.5 x 13 x 26 cm
Produkto svoris1.3 kilogramo
GamintojasGRE

8. Garantija ir palaikymas

For warranty information and technical support, please refer to the official Gre websvetainėje arba susisiekite su įgaliotuoju pardavėju. Išsaugokite pirkimo kvitą kaip pirkimo įrodymą.

Note: Information regarding spare parts availability is not provided in the product data.