1. Įvadas
This manual provides essential information for the proper use and maintenance of the DIGITEN Digital Humidity Sensor, Model DHC101SE. This replaceable hygrometer probe is designed for use with DIGITEN DHC101 Humidity Controllers to accurately monitor humidity levels in various environments, including those for humidifiers and dehumidifiers.
Please read this manual thoroughly before installation and operation to ensure optimal performance and longevity of your sensor.
2. Produktas baigtasview

Figure 2.1: DIGITEN Digital Humidity Sensor DHC101SE, showing the sensor probe and the attached 6-foot (2-meter) cable with a 3.5mm jack connector.

2.2 pav. Iš arti view of the DIGITEN Digital Humidity Sensor DHC101SE probe, highlighting the small sensor module and its 4-pin connector for attachment to the cable.
The DHC101SE is a high-precision digital humidity sensor designed for reliable and accurate humidity measurement. It features a durable 6-foot (2-meter) cable, making it suitable for various applications where remote sensing is required. The probe is easily replaceable, ensuring long-term usability with compatible humidity controllers.
3. Specifikacijos
| Funkcija | Detalė |
|---|---|
| Valdymo diapazonas | 5-99 % RH |
| Drėgmės skiriamoji geba | 0.1 % RH |
| Ekranas | %RH |
| Jutiklio modelis | MEAS HTG3500 series |
| Sensor Lead Length | 2 m (6 pėdos) |
| Prekės modelio numeris | DHC101SE |
| Gamintojas | SKAITMENINĖ |
| Prekės svoris | 8 uncijos (0.23 kilogramo) |
| Pakuotės matmenys | 8.2 x 4.6 x 0.6 colio |
4. Sąranka ir diegimas
- Suderinamumo patikrinimas: Ensure your humidity controller is compatible with the DIGITEN DHC101SE sensor. This probe is specifically designed for use with DIGITEN DHC101 series humidity controllers.
- Išpakuoti: Carefully remove the humidity sensor and its cable from the packaging. Inspect for any visible damage.
- Prijunkite zondą: The DHC101SE sensor probe connects to the main cable via a small 4-pin connector. Align the connector correctly and gently push until it clicks into place. Ensure a secure connection.
- Prisijungimas prie valdiklio: Locate the 3.5mm jack input port on your DIGITEN DHC101 humidity controller. Insert the 3.5mm jack from the sensor cable firmly into this port.
- Vieta: Position the sensor probe in the area where you need to monitor humidity. Ensure it is not directly exposed to water spray or extreme temperatures outside its operating range. For accurate readings, place the sensor away from direct airflow from humidifiers or dehumidifiers, allowing it to measure ambient humidity.
- Saugus kabelis: Route the cable neatly and securely to prevent accidental disconnections or damage.
5. Naudojimo instrukcijos
The DIGITEN DHC101SE is a passive sensor that provides humidity data to a compatible controller. Once properly connected to a DIGITEN DHC101 series humidity controller, the sensor will automatically begin transmitting humidity readings.
- Įjungimo valdiklis: Ensure your DHC101 humidity controller is powered on.
- Monitoriaus rodmenys: The humidity readings from the DHC101SE sensor will be displayed on the controller's screen.
- Valdiklio nustatymai: Refer to the instruction manual of your specific DIGITEN DHC101 humidity controller for details on setting target humidity levels, hysteresis, and other operational parameters. The sensor itself does not have user-adjustable settings.
6. Priežiūra
Regular maintenance ensures the accuracy and longevity of your humidity sensor.
- Valymas: Periodically inspect the sensor probe for dust, debris, or moisture buildup. Gently wipe the sensor surface with a soft, dry, lint-free cloth. Do not use abrasive cleaners or immerse the sensor in liquids.
- Venkite teršalų: Keep the sensor away from corrosive gases, high concentrations of chemicals, or environments with excessive dust or oil mist, as these can affect sensor accuracy and lifespan.
- Saugykla: If storing the sensor for an extended period, disconnect it from the controller and store it in a clean, dry environment within its specified operating temperature range.
- Pakeitimas: The DHC101SE is a replaceable probe. If the sensor becomes damaged or consistently provides inaccurate readings despite troubleshooting, it can be replaced without needing to replace the entire controller.
7. Problemų sprendimas
If you encounter issues with your DIGITEN Digital Humidity Sensor, refer to the following common troubleshooting steps:
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| No humidity reading on controller. | Sensor not properly connected to cable or controller. | Ensure both the 4-pin connector on the probe and the 3.5mm jack on the controller are securely inserted. |
| Netikslūs arba svyruojantys rodmenys. | Sensor dirty, damaged, or exposed to direct moisture/airflow. | Clean the sensor gently. Reposition the sensor away from direct water or strong airflow. If damage is suspected, consider replacement. |
| Controller not responding to humidity changes. | Sensor malfunction or controller issue. | Test with a known working sensor if available. If the sensor appears functional, refer to your DHC101 controller's manual for troubleshooting controller-specific issues. |
For issues not covered here, or if problems persist, please contact DIGITEN customer support.
8. Garantija ir palaikymas
Garantija: The DIGITEN Digital Humidity Sensor DHC101SE comes with a 1 metų garantija nuo įsigijimo datos. Ši garantija taikoma medžiagų ir gamybos defektams, atsiradusiems įprasto naudojimo sąlygomis. Ji netaikoma žalai, atsiradusiai dėl netinkamo naudojimo, nelaimingo atsitikimo, neleistinos modifikacijos ar netinkamo įrengimo.
Klientų aptarnavimas: For technical assistance, warranty claims, or any questions regarding your DIGITEN product, please contact DIGITEN customer support. You can find contact information on the official DIGITEN websvetainėje arba per savo pirkimo platformą.
Taip pat galite apsilankyti DIGITEN Store on Amazon Norėdami gauti daugiau informacijos ir paramos išteklių.





