1. Produktas baigtasview
The Elitech ECB-LS230-BL is a Bluetooth-enabled split electrical control box designed for precise temperature management. It features a large LED display for clear readings and remote monitoring capabilities. This control panel supports cooling, defrosting, and fan operations, offering a four-way output. Its split design separates the main controller from the display board, allowing for remote installation and enhanced safety.

Figure 1.1: Elitech ECB-LS230-BL Main Control Unit. This image shows the primary orange control box with blue mounting flanges, indicating its robust industrial design.
Pagrindinės funkcijos:
- Padalintas dizainas: Main controller separated from the display board for remote control up to 200 meters and safer installation.
- Large LED Touch Screen: Provides clear display and intuitive operation.
- Padidintas saugumas: Strong and weak electricity are separated due to the split design.
- Bluetooth ryšys: Allows parameter settings via a mobile application.
- Multi-functional Output: Supports refrigeration, defrosting, fan, and light control.
- Stebėjimas: Includes alarm, clock, and two storage temperature sensors.
2. Saugos informacija
Please read this manual carefully before installation and operation to ensure proper use and prevent damage or injury. Keep this manual for future reference.
- Ensure all wiring is performed by a qualified electrician in accordance with local and national electrical codes.
- Prieš atlikdami bet kokius montavimo, techninės priežiūros ar trikčių šalinimo darbus, atjunkite maitinimą.
- Nenaudokite prietaiso, jei jis pažeistas arba veikia netinkamai.
- Avoid exposing the device to excessive moisture, dust, or extreme temperatures outside its operating range.
- The split design separates strong and weak current circuits for safety; do not attempt to bypass or alter this design.
3. Diegimas ir sąranka
The ECB-LS230-BL features a split design, allowing the main control unit and the display panel to be installed separately. This provides flexibility and enhances safety by keeping high-voltage components away from user interaction points.
3.1 Main Control Unit Installation
Mount the main control unit in a secure, well-ventilated location, away from direct heat sources or excessive moisture. Use appropriate fasteners for the mounting brackets. Ensure sufficient space for wiring connections and heat dissipation.

Figure 3.1: Elitech ECB-LS230-BL Main Control Unit Side View. This image highlights the cooling fins and robust construction of the main unit.
3.2 Display Panel Installation
Install the large LED touch screen display panel in a convenient location for monitoring and operation. The display panel connects to the main control unit via a communication cable, allowing for remote placement up to 200 meters.
3.3 Elektros jungtys
Refer to the wiring diagram provided with your product packaging for detailed electrical connections. Ensure all power inputs (3-phase, 380V) and outputs (refrigeration, defrost, fan, light) are correctly wired. Connect the temperature sensors to the designated terminals. The RS485 port is used for communication with the mainboard.

Figure 3.2: Display Panel and Connections. This image illustrates the various indicators, control buttons, and the RS485 connection point on the display unit.
4. Naudojimo instrukcijos
The ECB-LS230-BL features a user-friendly LED touch screen and can also be controlled via a mobile application.
4.1 Display Panel Controls
The display panel provides real-time temperature readings and access to various functions:
- Temperatūros rodymas: Shows the current temperature in Celsius or Fahrenheit.
- Rodiklis L.amps: Separate indicators for defrosting, refrigeration, fan, unlock, communication, alarm, and light status.
- Force Defrosting Button: Initiates a manual defrost cycle.
- Setting/Unlock Button: Used to enter settings mode or unlock the panel.
- Upper/Light Button: Adjusts values upwards in settings or controls the light output.
- Apatinis mygtukas: Adjusts values downwards in settings.
- Pause/Exit Button: Pauses current operation or exits a menu.
4.2 Valdymas „Bluetooth“ programėle
The ECB-LS230-BL can be configured and monitored using a mobile application via Bluetooth. This allows for convenient parameter adjustments and remote data viewing without direct interaction with the display panel.
- Download the Elitech iCold application from your mobile device's app store.
- Įsitikinkite, kad jūsų mobiliajame įrenginyje įjungtas „Bluetooth“.
- Open the Elitech iCold app and follow the on-screen instructions to connect to your ECB-LS230-BL device.
- Prisijungę galite view real-time data, adjust parameters, and access historical graphs.

Figure 4.1: Bluetooth APP Monitoring. This image shows the display panel alongside a mobile phone demonstrating the Elitech iCold application's data logging and monitoring capabilities.
5. Priežiūra
Regular maintenance ensures the longevity and optimal performance of your ECB-LS230-BL control box.
- Valymas: Periodically clean the display panel with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Patikra: Reguliariai tikrinkite visas laidų jungtis, ar jos nėra įtemptos ir ar nėra nusidėvėjimo ar pažeidimų požymių.
- Vėdinimas: Ensure the main control unit's ventilation openings are clear of obstructions to prevent overheating.
- Programinės įrangos atnaujinimai: Check for firmware updates for the device and application updates for the Elitech iCold app to ensure you have the latest features and bug fixes.
6. Problemų sprendimas
If you encounter issues with your ECB-LS230-BL, refer to the following common troubleshooting steps:
- Nėra galios: Check the main power supply and all circuit breakers. Ensure all power connections to the control box are secure.
- Neteisingas temperatūros rodmuo: Verify that the temperature sensors are correctly connected and positioned. Check for any physical damage to the sensor cables.
- Ekranas nereaguoja: Ensure the communication cable between the main unit and the display panel is securely connected. Try restarting the unit by cycling the power.
- „Bluetooth“ ryšio problemos: Ensure Bluetooth is enabled on your mobile device and the control box. Try restarting both devices. Make sure the app is up to date.
- Išėjimas neaktyvuojamas: Check the set parameters for refrigeration, defrost, fan, or light. Verify wiring to the respective loads.
- Suveikė signalizacija: Check the alarm code displayed (if any) and consult the full product manual for specific alarm definitions and remedies.
For persistent issues, contact Elitech customer support.
7. Specifikacijos
| Specifikacija | Vertė |
|---|---|
| Prekės ženklas | Elitech |
| Modelio numeris | ECB-LS230-BL |
| ttage | 380 voltų |
| Galios įvertinimas | 10Hp (Horsepower) |
| Fazė | 3 fazė |
| Ryšys | Bluetooth |
| Ekranas | Large LED Touch Screen |
| Nuotolinio valdymo atstumas | Up to 200 meters (display to main unit) |
| Funkcijos | Refrigeration, Defrosting, Fan, Light (four-way output) |
| Jutikliai | Two storage temperature sensors |
| UPC | 781454242351 |
8. Garantija ir palaikymas
Elitech products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official Elitech website. For technical support, troubleshooting assistance, or service inquiries, please contact Elitech customer service through their official channels.
Elitech Customer Support: Please visit the Elitech websvetainėje, kurioje rasite kontaktinę informaciją ir pagalbos išteklius.