1. Įvadas

This manual provides essential information for the proper installation, operation, and maintenance of the Supermicro PWS-406P-1R 1U 400W Redundant Short Depth Power Supply. This power supply is designed for enterprise-level applications requiring high quality, reliability, and power efficiency. It features a 1U form factor, 400W output, and redundant capabilities to ensure continuous system operation.

2. Saugos informacija

Please read and understand all safety instructions before installing or operating this power supply. Failure to follow these instructions may result in electric shock, fire, or damage to the equipment.

  • Kvalifikuotas personalas: Installation and servicing should only be performed by qualified service personnel.
  • Maitinimo atjungimas: Always disconnect the power cord from the AC outlet before installing, removing, or servicing the power supply.
  • Įžeminimas: Ensure the power supply is properly grounded to prevent electric shock.
  • Vėdinimas: Do not block ventilation openings. Ensure adequate airflow around the power supply to prevent overheating.
  • Drėgmė: Do not expose the power supply to moisture or operate it in high-humidity environments.
  • Perkrova: Do not overload the power supply beyond its specified wattage.

3. Produktas baigtasview

The Supermicro PWS-406P-1R is a 400W redundant power supply designed for 1U server chassis. Its short depth form factor allows for installation in various server configurations. Key features include high efficiency (Platinum/Gold Level), quiet operation, and support for remote monitoring via PMBus.

Supermicro PWS-406P-1R 1U 400W Redundant Short Depth Power Supply

Kampinis view of the Supermicro PWS-406P-1R power supply unit, showing its compact form factor, ventilation grille, power input connector, and product label with specifications and certifications.

4. Sąranka ir diegimas

This power supply is typically installed in a compatible 1U server chassis that supports redundant power supply units. Refer to your server chassis manual for specific installation instructions.

  1. Paruošimas: Ensure the server system is powered off and disconnected from all power sources.
  2. Raskite įlanką: Identify the designated power supply bay in your server chassis.
  3. Insert PSU: Carefully slide the PWS-406P-1R power supply into the bay until it clicks securely into place. For redundant configurations, install a second identical unit.
  4. Prijunkite maitinimą: Connect the AC power cord to the power supply's input connector and then to a grounded AC outlet.
  5. Maitinimas: Power on the server system and verify that the power supply status indicators are normal.

Pastaba: This power supply is hot-swappable, meaning it can be replaced or added while the system is running, provided the other redundant power supply is operational and the system supports hot-swapping.

5. Naudojimo instrukcijos

Once installed, the Supermicro PWS-406P-1R operates automatically. The primary function is to convert AC power from the wall outlet into stable DC power for the server components.

  • Būklės rodikliai: Observe the LED indicators on the power supply. Typically, a green LED indicates normal operation, while an amber or red LED may indicate a fault or standby mode. Refer to your server's documentation for specific LED interpretations.
  • Atleidimas: In a redundant configuration, if one power supply fails, the other unit(s) will seamlessly take over the full load, ensuring continuous system uptime.
  • Nuotolinis stebėjimas: If your server system supports PMBus, the power supply's status, voltage, current, and temperature can be monitored remotely via management software.

6. Priežiūra

The Supermicro PWS-406P-1R is designed for high reliability and requires minimal maintenance. However, periodic checks can help ensure optimal performance and longevity.

  • Vizuali apžiūra: Periodically inspect the power supply and its connectors for any signs of damage, loose connections, or excessive dust accumulation.
  • Valymas: If dust accumulates on the fan or vents, gently clean it using compressed air. Ensure the system is powered off and unplugged before cleaning. Do not use liquid cleaners.
  • Firmware atnaujinimai: While power supplies typically do not require frequent firmware updates, consult your server manufacturer's documentation for any recommended updates related to power management.

7. Problemų sprendimas

Jei kyla problemų dėl maitinimo šaltinio, apsvarstykite šiuos trikčių šalinimo veiksmus:

  • Nėra galios:
    • Patikrinkite, ar kintamosios srovės maitinimo laidas yra tvirtai prijungtas tiek prie maitinimo šaltinio, tiek prie sieninio lizdo.
    • Check the wall outlet for power by plugging in another device.
    • Ensure the server's power button is functioning correctly.
  • Faulty LED Indicator:
    • If an amber or red LED is illuminated, it indicates a potential fault. If in a redundant configuration, the other power supply should be maintaining system operation.
    • Attempt to reseat the power supply unit.
    • If the issue persists, the power supply may need replacement.
  • System Instability/Unexpected Shutdowns:
    • Ensure the power supply is adequately rated for the total power consumption of your server components.
    • Check for proper ventilation to prevent overheating.
    • If you have multiple power supplies, test them individually if possible to isolate the faulty unit.

For persistent issues, contact Supermicro technical support or your system integrator.

8. Specifikacijos

FunkcijaSpecifikacija
Modelio pavadinimasPWS-406P-1R
Prekės ženklasSupermikro
Išėjimo vattage400 vatų
Formos faktoriusATX (1U Short Depth)
Jungties tipasATX
Aušinimo būdasOras
Gaminio matmenys (I x P x A)8.66 x 2.15 x 1.57 colio
Prekės svoris1 svaro
Suderinami įrenginiaiServeris

9. Garantija ir palaikymas

Warranty information for the Supermicro PWS-406P-1R power supply is typically provided by the vendor or system integrator from whom the product was purchased. Please refer to your purchase documentation for specific warranty terms and conditions.

For technical support, please contact your Supermicro reseller or the Supermicro official support channels. Ensure you have your product model number (PWS-406P-1R) and any relevant system information available when seeking assistance.

Susiję dokumentai - PWS-406P-1R

Preview „SuperWorkstation 5035B-T“ naudotojo vadovas – diegimo ir naudojimo vadovas
Išsamus „SuperWorkstation 5035B-T“ naudotojo vadovas, kuriame išsamiai aprašomas diegimas, sąranka, sistemos sąsaja, saugos priemonės, serverio plokštės ir korpuso konfigūracija, BIOS nustatymai ir sistemos specifikacijos. Įskaitant rekomendacijas profesionaliems sistemų integratoriams ir kompiuterių technikams.
Preview „Supermicro SuperChassis 813MTQ-350CB“: 1U serverio korpuso specifikacijos ir komponentai
Išsamios „Supermicro SuperChassis 813MTQ-350CB“ – 1U serverio korpuso, sukurto dideliam našumui ir patikimumui užtikrinti, specifikacijos, pagrindinės savybės ir komponentų sąrašas. Įtraukta informacija apie pagrindinių plokščių ir serverių suderinamumą.
Preview „Supermicro C7Z87-OCE“ pagrindinės plokštės naudotojo vadovas
Šiame vartotojo vadove pateikiama išsami informacija apie „Supermicro C7Z87-OCE“ pagrindinės plokštės diegimą, konfigūravimą ir trikčių šalinimą, įskaitant specifikacijas, BIOS nustatymus ir aparatinės įrangos jungtis sistemų integratoriams ir IT specialistams.
Preview „Supermicro SuperServer SYS-212HA-TN“ greitasis informacinis vadovas
Trumpas „Supermicro SuperServer SYS-212HA-TN“ informacinis vadovas, kuriame išsamiai aprašomas plokštės išdėstymas, atminties palaikymas, procesoriaus diegimas ir disko kabelio išdėstymas sistemos sąrankai.
Preview „Supermicro X11DAi-N“ naudotojo vadovas
Šiame naudotojo vadove pateikiama išsami informacija apie „Supermicro X11DAi-N“ pagrindinės plokštės diegimą ir naudojimą, įskaitant funkcijas, specifikacijas, trikčių šalinimą ir BIOS sąranką.
Preview „Supermicro AOC-SLG4-4E4T NVMe“ išplėtimo plokštės naudotojo vadovas
Oficialus „Supermicro AOC-SLG4-4E4T NVMe“ išplėtimo plokštės naudotojo vadovas, kuriame išsamiai aprašomos jos funkcijos, aparatinės įrangos komponentai, diegimas ir BIOS nustatymai įmonės klasės serverių platformoms.