Izoxis 19923

Izoxis Digital Timer Plug Model 19923

Instrukcijų vadovas

1. Įvadas

The Izoxis Digital Timer Plug Model 19923 is designed to provide automated control over electrical appliances in your home or office. This device allows you to set precise on/off times for connected equipment, helping to manage energy consumption and enhance home security. Featuring an easy-to-read display and intuitive controls, it supports 230V appliances such as lighting, heating, or other electronics. By automating power cycles, you can prevent unnecessary energy use and create the impression of occupancy when away.

2. Saugos informacija

  • Do not exceed the maximum load of 3680W or 16A.
  • Šis prietaisas skirtas naudoti tik patalpose. Saugokite jį nuo drėgmės ar ekstremalių temperatūrų.
  • Ensure the timer is securely plugged into a grounded wall socket.
  • Neardykite ir nebandykite taisyti įrenginio. Dėl remonto kreipkitės į kvalifikuotus specialistus.
  • Laikyti vaikams nepasiekiamoje vietoje.
  • Prieš valydami atjunkite laikmatį nuo elektros lizdo.

3. Produktas baigtasview

Familiarize yourself with the components and controls of your Izoxis Digital Timer Plug.

Priekyje view of Izoxis Digital Timer Plug with dimensions

3.1 paveikslas: Priekyje view of the Izoxis Digital Timer Plug, showing the display, control buttons, and socket. Dimensions are indicated as 11.2 cm height, 7.5 cm width, and 5.5 cm depth.

Close-up of Izoxis Digital Timer Plug display and buttons

3.2 paveikslas: Iš arti view of the timer's digital display and control buttons. The buttons include SET, CLOCK, PROG, UP, OK, RESET, and CLEAR.

Valdikliai:

  • NUSTATYTI: Enters setting mode for time and programs.
  • LAIKRODIS: Naudojamas dabartiniam laikui ir dienai nustatyti.
  • PROGRAMA: Used to set ON/OFF programs.
  • AUKŠTYN: Adjusts values upwards during setting.
  • GERAI: Patvirtina pasirinkimus.
  • NUSTATYTI: Clears all settings and returns to factory defaults.
  • IŠVALYTI: Deletes current program settings.

4. Sąranka

Follow these steps for initial setup of your timer plug.

  1. Pradinis mokestis: Plug the timer into a live wall socket for at least 30 minutes to charge the internal battery. This retains settings during power outages.
  2. Iš naujo nustatyti įrenginį: Paspauskite RESET button using a small pointed object (e.g., a pen tip) to clear all previous settings. The display will show 00:00.
  3. Nustatyti dabartinį laiką:
    • Paspauskite LAIKRODIS mygtuką. Mirksės valandų skaičius.
    • Naudokite UP mygtuką, norėdami reguliuoti valandas.
    • Paspauskite OK to confirm the hour. The minute digit will flash.
    • Naudokite UP mygtuką, kad nustatytumėte minutes.
    • Paspauskite OK to confirm the minute. The day of the week will flash.
    • Naudokite UP button to select the current day (MO, TU, WE, TH, FR, SA, SU).
    • Paspauskite OK to save the current time and day.
  4. 12/24 valandų režimas: To switch between 12-hour and 24-hour display, press the LAIKRODIS mygtuką ir tada UP mygtuką vienu metu.
  5. Vasaros laikas: To activate or deactivate summer time, press the LAIKRODIS mygtuką ir tada NUSTATYTI button simultaneously. An 'S' will appear on the display when summer time is active.
Izoxis Digital Timer Plug plugged into a wall socket

4.1 paveikslas: The Izoxis Digital Timer Plug correctly inserted into a standard wall socket, ready for use.

5. Naudojimo instrukcijos

This section details how to program and operate your timer plug.

5.1. Programų nustatymas (ĮJUNGIMO / IŠJUNGIMO laikas)

The timer allows for multiple ON/OFF programs. To set a program:

  1. Paspauskite PROG button. The display will show "1 ON" and the hour digit will flash.
  2. Naudokite UP button to set the desired ON hour for the first program. Press OK.
  3. Naudokite UP button to set the desired ON minute. Press OK.
  4. Naudokite UP button to select the day(s) for this ON program (e.g., MO-FR, SA-SU, or individual days). Press OK.
  5. The display will now show "1 OFF" and the hour digit will flash. Repeat steps 2-4 to set the desired OFF time and day(s) for the first program.
  6. After setting "1 OFF", press PROG again to move to "2 ON" and repeat the process for additional programs.
  7. Kai visos programos nustatytos, paspauskite LAIKRODIS mygtuką, kad grįžtumėte į dabartinio laiko rodymą.

5.2. Manual Override Modes

The timer has different operating modes:

  • AUTOMATINIS: The timer operates according to the programmed ON/OFF times. This is the default and recommended mode.
  • ĮJUNGTA: The connected appliance is continuously ON, overriding all programs.
  • IŠJUNGTA: The connected appliance is continuously OFF, overriding all programs.

To cycle through these modes, press the NUSTATYTI button repeatedly until the desired mode (AUTO, ON, or OFF) is displayed.

Izoxis Digital Timer Plug in use with a USB charger plugged in

5.1 paveikslas: The Izoxis Digital Timer Plug actively controlling a connected USB charger, demonstrating its practical application.

6. Priežiūra

To ensure the longevity and proper functioning of your timer plug, follow these maintenance guidelines:

  • Valymas: Prieš valydami atjunkite laikmatį nuo maitinimo lizdo. Išorę nuvalykite minkšta, sausa šluoste. Nenaudokite skystų valiklių ar abrazyvinių medžiagų.
  • Saugykla: If storing the timer for an extended period, ensure it is clean and dry. Store in a cool, dry place away from direct sunlight.
  • Baterija: The internal battery is designed to retain settings. If the display is blank or settings are lost frequently, ensure the timer is plugged in for sufficient time to charge the battery.

7. Problemų sprendimas

If you encounter issues with your Izoxis Digital Timer Plug, refer to the following common problems and solutions:

ProblemaGalima priežastisSprendimas
Ekranas tuščias arba nereaguoja.Vidinė baterija išsikrovusi.Plug the timer into a live wall socket for at least 30 minutes to charge the battery.
Programos neaktyvuojasi.Laikmatis nėra automatiniame režime. Neteisingi programos nustatymai.Įsitikinkite, kad laikmatis nustatytas ties AUTO režimas. Pakartotinaiview and re-enter your program settings carefully.
Connected appliance does not turn ON/OFF.Appliance is faulty. Timer is faulty.Test the appliance by plugging it directly into a wall socket. If the appliance works, the timer may be faulty.
Time or settings are lost after unplugging.Internal battery not fully charged or failing.Ensure the timer is plugged in for a longer duration (e.g., 24 hours) to fully charge the battery. If the problem persists, the battery may need service.

8. Specifikacijos

Modelis:19923
Prekinis ženklas:Izoksis
Spalva:Baltas
ttage:230 V / Hz 50
Didžiausia galia:3680 W
Didžiausia srovė:16 A
Darbinė temperatūra:0–50 °C
Veikimo režimas:24/12 valandų
Summer Time Adjustment:Taip
Matmenys (P x P x A):11.2 x 7.5 x 5.5 cm
Svoris:0.143 kg

9. Garantija ir palaikymas

Specific warranty information for the Izoxis Digital Timer Plug Model 19923 is not provided in the product details. For warranty claims or technical support, please contact your retailer or the manufacturer directly using the contact information provided at the point of purchase.

Susiję dokumentai - 19923

Preview Izoxis YYK-520 Bluetooth Headset User Manual
User manual for the Izoxis YYK-520 Bluetooth headset, providing instructions on setup, pairing, button functions, troubleshooting, and safety guidelines. Discover the ease of wireless connectivity and enjoy clear audio for calls and music.
Preview Domus Blaze-Pro-Marine-100 Floodlight F&P - Product Overview ir specifikacijos
Detailed product information for the Domus Blaze-Pro-Marine-100 Floodlight F&P, featuring marine-grade construction, IP66 rating, tri-colour LED technology, and optional sensor compatibility. Ideal for outdoor and coastal environments.