This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outages.
Key features of the CM8100 Console Server include:
- 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
- Support for Data Center and Enterprise Network automation with Python and Docker.
- Embedded physical security via TPM 2.0 module.
- Dual power supplies for redundancy and independent monitoring.
- Integrated environmental temperature monitoring.
Sąranka ir diegimas
This section guides you through the physical installation and initial setup of your CM8100 Console Server.
Įrenginio išpakavimas
Atsargiai išpakuokite visus komponentus iš dėžės. Patikrinkite, ar yra visi skyriuje „Kas yra dėžėje“ išvardyti elementai ir ar jie nepažeisti.
Vaizdas: priekis view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.
Stovo montavimas
The CM8100 Console Server is designed for standard 19-inch rack installation.
- Attach the two rack ears to the sides of the console server using the provided M4 screws.
- Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.
Maitinimo prijungimas
The CM8100 features dual power supplies for redundancy.
- Connect the two A/C power cables to the power inlets on the rear of the console server.
- Connect the other ends of the power cables to independent power sources for redundancy.
- Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.
Tinklo ryšys
Connect the console server to your network for management access.
- Connect an Ethernet cable from your network switch to the primary network port on the console server.
- (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.
Nuosekliojo prievado jungtis
Connect your managed devices (servers, network devices) to the serial ports on the CM8100.
- Identify the serial ports on the rear of the console server.
- Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
- Note the port numbers for future configuration.
Vaizdas: Galinis view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.
Operacija
This section covers basic operation and initial access to the CM8100 Console Server.
Pradinė prieiga
Access the console server for initial configuration via a direct serial connection or network connection.
Serial Console Access
- Connect a computer to the console server's dedicated console port using a serial cable.
- Sukonfigūruokite terminalo emuliacijos programinę įrangą (pvz., „PuTTY“, „Tera Term“) su šiais nustatymais: 115200 baudų, 8 duomenų bitai, be lyginumo, 1 stop bitas, be srauto valdymo.
- Power on the CM8100. The boot process will display on your terminal.
- Log in using the default credentials (refer to the Quick Start Guide for default username and password).
Network Access (Web Sąsaja)
Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web sąsaja.
- Atidarykite a web browser and enter the IP address of the CM8100.
- Prisijunkite naudodami savo kredencialus.
- Iš web interface, you can configure serial ports, network settings, user accounts, and other system parameters.
Prijungtų įrenginių valdymas
The CM8100 allows you to connect to the console of your attached devices.
- Nuosekliojo jungties konsolės prieiga: Iš web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
- Out-of-Band Management: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.
Priežiūra
Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.
Programinės aparatinės įrangos naujiniai
Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.
- Download the latest firmware image from the official Opengear support portal.
- Access the CM8100 web sąsaja.
- Navigate to the firmware update section (typically under System > Firmware).
- Follow the on-screen instructions to upload and install the new firmware. Do not power off the device during the update process.
Valymas
Keep the console server clean to prevent dust buildup, which can affect cooling.
- Prietaiso išorę nuvalykite minkšta, sausa šluoste.
- Įsitikinkite, kad ventiliacijos angose nėra kliūčių.
- Nenaudokite skystų valiklių tiesiai ant prietaiso.
Aplinkosaugos svarstymai
Ensure the operating environment meets the recommended conditions.
- Maintain proper airflow around the device.
- Keep the device within specified temperature and humidity ranges.
Trikčių šalinimas
This section provides solutions to common issues you might encounter with the CM8100 Console Server.
Nėra galios
- Simptomai: Power indicator LEDs are off, device does not respond.
- Sprendimas: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.
Nepavyksta pasiekti Web Sąsaja
- Simptomai: Web browser cannot connect to the CM8100 IP address.
- Sprendimas:
- Verify the console server has power and is running.
- Confirm the network cable is properly connected to an active network port.
- Check the IP address configuration of the CM8100 (via serial console if necessary).
- Ensure your computer is on the same network or has a route to the CM8100's IP address.
- Temporarily disable any firewalls on your computer to rule out interference.
No Serial Console Connection to Managed Device
- Simptomai: Unable to establish a serial connection to a device connected to the CM8100.
- Sprendimas:
- Verify the serial cable connection between the CM8100 port and the managed device.
- Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
- Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
- Confirm the managed device is powered on and functioning correctly.
Specifikacijos
| Funkcija | Detalė |
|---|---|
| Prekės ženklas | „Opengear“ |
| Serija | CM8100 Console Server |
| Modelio numeris | CM8116 |
| Prekės svoris | 8.63 svaro |
| Gaminio matmenys (IxPxH) | 19.5 x 16.5 x 3.5 colio |
| Gamintojas | „Opengear“ |
| Pirmas prieinamas | 16 m. vasario 2023 d |
Kas yra dėžutėje
The following items are included with your Opengear CM8100 Console Server:
- CM8100 Console Server
- Rack Mount Kit
- 2 x Rack Ears with Six M4 Screws
- 4 x M5mm Caged Nuts
- 4 x M5x15mm Rack Screws
- 1 x CAT5 Patch Cable 6'
- 1 x DB9F-RJ45 Rollover Serial Adapter
- 2 x A/C Power Cables
- Greitos pradžios vadovas
- Lighthouse Insert