1. Įvadas
The Moxa MGate 5121-T is a 1-port industrial Ethernet gateway designed for converting CANopen or J1939 protocols to Modbus TCP. This device facilitates seamless communication between CAN-based devices and Modbus TCP networks, commonly found in industrial automation and control systems. It supports a wide operating temperature range of -40 to 75°C, making it suitable for harsh industrial environments.
2. Saugos informacija
Please read and understand all safety instructions before installing or operating the MGate 5121-T gateway. Failure to follow these instructions may result in equipment damage, personal injury, or system malfunction.
- Prieš montuodami arba atlikdami techninę priežiūrą įsitikinkite, kad maitinimas yra atjungtas.
- Install the device in a well-ventilated area, away from excessive heat, moisture, or corrosive substances.
- Montavimo metu naudokite tinkamus įrankius ir asmenines apsaugos priemones.
- All wiring should comply with local and national electrical codes.
- Montuoti ir prižiūrėti turėtų tik kvalifikuoti darbuotojai.
3. Pakuotės turinys
Patikrinkite, ar jūsų pakuotėje yra šie elementai:
- MGate 5121-T Gateway Unit
- Greito montavimo vadovas
- Garantijos kortelė
- (Optional) DIN-rail mounting kit
If any of these items are missing or damaged, please contact your sales representative for assistance.
4. Produktas baigtasview
4.1 Pagrindinės savybės
- Converts CANopen/J1939 to Modbus TCP
- 1 CAN port, 1 Ethernet port
- Wide operating temperature: -40 to 75°C
- Redundant power inputs
- Web-pagrįsta konfigūracija
- Montuojamas ant DIN bėgelio
4.2 Aparatūros aprašymas
The MGate 5121-T features a robust metal casing designed for industrial environments. It includes LED indicators for power, status, and communication activity, allowing for quick visual diagnostics. The device provides screw terminals for power input and CAN bus connections, and an RJ45 port for Ethernet connectivity.
Note: No suitable product images were provided in the input data for embedding. If available, images showing the front panel, side view with ports, and LED indicators would be placed here with descriptive alt-text.
5. Sąranka
5.1 Montavimas
The MGate 5121-T can be mounted on a standard 35mm DIN-rail or wall-mounted using the optional wall-mounting kit.
- Montavimas ant DIN bėgelio: Attach the DIN-rail clip to the back of the device. Hook the top of the clip onto the DIN-rail and push the bottom until it snaps into place.
- Montavimas ant sienos: Secure the wall-mounting plates (if applicable) to the device using screws. Mark and drill holes on the wall, then attach the device using appropriate screws.
5.2 Maitinimo jungtis
The gateway supports redundant DC power inputs. Connect a 12-48 VDC power supply to the terminal block labeled "PWR1" and "PWR2". Ensure correct polarity. It is recommended to connect both power inputs for redundancy.
- Vielos matuoklis: Use 12-24 AWG (0.2 to 2.5 mm²) wires for power connections.
- Sukimo momentas: Tighten terminal block screws to 0.5 Nm (4.4 lb-in).
5.3 Tinklo jungtis
- Ethernet (Modbus TCP): Connect an Ethernet cable from the gateway's RJ45 port to your Modbus TCP network switch or controller.
- CAN (CANopen/J1939): Connect the CAN bus wires (CAN_H, CAN_L, GND) to the corresponding terminals on the gateway. Ensure proper termination resistors are used on the CAN bus as per CAN specifications.
5.4 Pradinė konfigūracija
The MGate 5121-T can be configured via its web console. By default, the device obtains an IP address via DHCP. If no DHCP server is available, it will revert to a default static IP address (e.g., 192.168.1.254).
- Connect your PC to the same network as the gateway.
- Atidarykite a web browser and enter the gateway's IP address.
- Log in using the default credentials (refer to the Quick Installation Guide for default username/password).
- Configure the CANopen/J1939 and Modbus TCP settings according to your network requirements.
6. Šliuzo valdymas
6.1 Pagrindinės operacijos
Once configured, the MGate 5121-T operates as a protocol converter, transparently translating data between the CANopen/J1939 network and the Modbus TCP network. Modbus TCP masters can read/write data from/to CANopen/J1939 slaves mapped within the gateway's configuration.
6.2 LED indikatoriai
The gateway features several LED indicators to provide status information:
- PWR1/PWR2: Solid green when power input is active.
- STATUSAS: Indicates device operational status (e.g., solid green for normal operation, blinking for errors). Refer to the full user manual for detailed status codes.
- GALI: Indicates CAN bus activity (e.g., blinking when data is transmitted/received).
- LAN (Link/Act): Solid green for link, blinking for activity on the Ethernet port.
Note: No suitable product videos were provided in the input data for embedding. If available, a video demonstrating LED indicator behavior or initial web configuration steps would be placed here with a descriptive text description.
7. Priežiūra
7.1 Valymas
Periodically clean the exterior of the device with a soft, dry cloth. Do not use liquid or aerosol cleaners, as they may damage the device.
7.2 Firmware atnaujinimai
Moxa may release firmware updates to improve performance, add features, or address security vulnerabilities. Check the Moxa website regularly for the latest firmware versions and instructions on how to perform updates.
7.3 Aplinkosaugos aspektai
Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage and ensure reliable operation.
8. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| No Power LED (PWR1/PWR2) | No power supply connected or faulty power supply/cabling. | Check power connections, power supply voltage, and cable integrity. Ensure polarity is correct. |
| Nėra eterneto ryšio | Faulty Ethernet cable or network device. Incorrect network settings. | Verify Ethernet cable connection. Check network switch/router status. Confirm IP address settings. |
| No CAN Communication | Incorrect CAN wiring, missing termination resistors, or incorrect CAN bus parameters. | Check CAN_H/CAN_L wiring. Ensure 120Ω termination resistors are present at both ends of the bus. Verify CAN baud rate and other parameters in configuration. |
| Modbus TCP Master cannot access CAN devices | Incorrect Modbus TCP mapping or CANopen/J1939 device configuration. | Review the gateway's Modbus TCP mapping table. Verify CANopen/J1939 device IDs and object dictionary entries. |
8.1 Gamyklinių parametrų atkūrimas
If the device becomes unresponsive or configuration issues persist, a factory reset may be necessary. Refer to the full user manual for the specific procedure, which typically involves pressing and holding a reset button for a certain duration.
9. Specifikacijos
| Parametras | Vertė |
|---|---|
| Modelis | MGate 5121-T |
| Palaikomi protokolai | CANopen, J1939, Modbus TCP |
| CAN prievadas | 1 x CAN (DB9 or Terminal Block, depending on variant) |
| Ethernet prievadas | 1 x 10/100BaseT(X) auto-negotiating, RJ45 |
| Įvesties tomastage | 12-48 VDC (Redundant inputs) |
| Energijos suvartojimas | Typically < 5 W (Exact value varies by operation) |
| Darbinė temperatūra | -40 iki 75°C (nuo -40 iki 167°F) |
| Laikymo temperatūra | -40 iki 85°C (nuo -40 iki 185°F) |
| Drėgmė | Nuo 5 iki 95 % RH (nekondensuojantis) |
| Matmenys (P x G x A) | Specific dimensions vary; refer to product datasheet. |
| Būstas | Metalinis, IP30 apsauga |
| Montavimas | DIN-rail, Wall-mount |
| Sertifikatai | CE, FCC, UL (Specific certifications vary by region/model) |
10. Garantija ir palaikymas
10.1 Gaminio garantija
Moxa products are covered by a limited warranty. The warranty period and terms vary by product and region. Please refer to the warranty card included with your product or visit the official Moxa websvetainėje rasite išsamią informaciją apie garantiją.
10.2 Techninė pagalba
For technical assistance, product documentation, or software downloads, please visit the Moxa websvetainė adresu www.moxa.com/support. You can also contact Moxa technical support directly via phone or email, details of which are available on their support page.