1. Įvadas
Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.
2. Saugos instrukcijos
Visada laikykitės šių saugos priemonių, kad išvengtumėte sužalojimų ar įrenginio pažeidimo:
- Elektros sauga: Ensure the device is connected to a properly grounded power outlet. Do not open the casing; viduje nėra dalių, kurias galėtų aptarnauti vartotojas. Visus techninės priežiūros darbus patikėkite kvalifikuotiems darbuotojams.
- Baterijos prijungimas: Connect the battery with correct polarity (red to positive, black to negative). Incorrect connection can cause severe damage to the inverter and battery. Use a 12V DC battery with a capacity between 50-200 Ah (55 Ah suggested).
- Vėdinimas: Ensure adequate ventilation around the unit. Do not block the fan or ventilation openings. Overheating can lead to device malfunction or damage.
- Aplinka: Operate the device within the specified temperature range of 0 - 40°C and humidity of 10 - 90%. Avoid direct sunlight, moisture, dust, and corrosive environments.
- Apsauga nuo perkrovos: Do not exceed the rated power of 700 W. The device is equipped with overload protection, but continuous overloading can shorten its lifespan.
- Skysčio kontaktas: Keep the device away from liquids. In case of accidental liquid contact, immediately disconnect power and consult a service technician.
- Vaikai ir augintiniai: Prietaisą laikykite vaikams ir naminiams gyvūnėliams nepasiekiamoje vietoje.
3. Gaminio komponentai
Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

3.1 paveikslas: Priekinis skydelis
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

3.2 pav.: Galinio skydelio viršusview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.
3.3 pav.: Galinio skydelio jungčių detalės
Arčiau view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.
Pagrindiniai komponentai:
- Skystųjų kristalų ekranas: Provides real-time information on operating status, battery charge level, and load level.
- Main ON/OFF Switch: Valdo keitiklio galią.
- Kintamosios srovės išvesties lizdai: Two 230V AC sockets for connecting your devices.
- Battery Terminals (12V DC): Connect to an external 12V DC battery. Ensure correct polarity.
- Kintamosios srovės įvestis (230 V): Connects the inverter to the mains power supply for charging the battery and providing power in UPS mode.
- Aušinimo ventiliatorius: Dissipates heat generated during operation.
- Grandinės pertraukiklis: Suteikia apsaugą nuo viršsrovės.
4. Sąranka
Follow these steps to set up your Rebel POWER-1000 UPS Inverter:
- Išpakavimas: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
- Vieta: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
- Baterijos prijungimas:
- Ensure the inverter is switched OFF.
- Prijunkite raudona akumuliatoriaus laidas prie teigiamas (+) jūsų 12 V nuolatinės srovės akumuliatoriaus gnybtą.
- Prijunkite juodas akumuliatoriaus laidas prie neigiamas (-) jūsų 12 V nuolatinės srovės akumuliatoriaus gnybtą.
- Tighten all connections securely to prevent arcing.
- Kintamosios srovės tinklo prijungimas: Prijunkite keitiklio kintamosios srovės įvesties laidą į standartinį 230 V kintamosios srovės sieninį lizdą.
- Įrenginio prijungimas: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.
5. Naudojimo instrukcijos
The Rebel POWER-1000 operates in three main modes:
- UPS Mode (Emergency Power Supply): When connected to mains power, the inverter charges the external battery and simultaneously supplies power to connected devices. In case of a power outage, it automatically switches to battery power within <4 ms, providing uninterrupted power.
- Rectifier Mode (Battery Charger): When connected to mains power without any load, the inverter functions as a battery charger, replenishing the external battery.
- Inverterio režimas: When not connected to mains power, the inverter converts 12V DC battery power into 230V AC pure sine wave power for your connected devices.
Starting the Inverter:
- Ensure all connections (battery, AC input, loads) are secure.
- Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
- The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.
LED ekrano informacija:
The clear LED display provides crucial information:
- Įvesties tomastage: Rodo įeinančio kintamosios srovės garsumątage iš elektros tinklo.
- Išėjimas ttage: Rodo 230 V kintamosios srovės išėjimo garsumątage.
- Baterijos tūristage: Nurodo esamą ttagPrijungto 12 V akumuliatoriaus įtampa.
- Apkrovos lygis: Rodo proctage of the inverter's capacity being used by connected devices.
- Veikimo būsena: Icons or indicators for mains power, battery power, charging, and fault conditions.
6. Priežiūra
Reguliarus techninis aptarnavimas užtikrina optimalų keitiklio veikimą ir ilgaamžiškumą:
- Valymas: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure the cooling fan and ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Akumuliatoriaus patikrinimas: Regularly check battery terminals for corrosion and ensure connections are tight. If using a lead-acid battery, check electrolyte levels if applicable and top up with distilled water as needed (refer to battery manufacturer's instructions).
- Vėdinimas: Always ensure the inverter has adequate ventilation. Do not place objects on top of the unit or block its air vents.
- Saugykla: If storing the inverter for an extended period, disconnect it from both mains power and the battery. Store in a cool, dry place. For optimal battery health, fully charge the battery before storage and recharge it every 3-6 months.
7. Problemų sprendimas
If you encounter issues with your Rebel POWER-1000, refer to the following table:
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Inverteris neįsijungia | No battery connected or battery discharged; Main switch off; Blown circuit breaker. | Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel. |
| Nėra kintamosios srovės išvesties | Overload; Short circuit; Battery low; Inverter fault. | Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support. |
| Akumuliatorius neįkraunamas | Kintamosios srovės įvestis neprijungta; kintamosios srovės įvesties garsumastage too low/high; Battery fault. | Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty. |
| Perkrovos įspėjimas ekrane | Total power of connected devices exceeds 700 W. | Disconnect some devices to reduce the load below 700 W. |
| Unit is unusually hot | Blocked ventilation; Excessive load; High ambient temperature. | Ensure vents are clear; Reduce load; Move unit to a cooler environment. |
If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.
8. Specifikacijos
Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):
| Funkcija | Specifikacija |
|---|---|
| Nominali galia | 700 W (1000 VA) |
| Baterijos tipas | 12 V DC |
| Maksimalus akumuliatoriaus tūristage | 15 V DC |
| Įvesties tomastage Diapazonas | 190–260 V kintamoji srovė |
| Įvesties dažnis | 45–20 000 Hz |
| Išėjimas ttage (AC) | 230 V AC +/-5% (Inverter: 230 V AC +/-3%) |
| Išvesties dažnis | 50/60 Hz +/-0.5 Hz |
| Išvesties bangos forma | Gryna sinuso banga |
| Rezultato efektyvumas | >= 85% (DC to AC) |
| Akumuliatoriaus įkrovimo srovė | Maks. 10 A |
| Siūloma akumuliatoriaus talpa | 50-200 Ah (suggested: 55 Ah) |
| Numatomas įkrovimo laikas | 4-14 hours (dependent on battery capacity) |
| Perjungimo laikas | =<4 ms |
| Apsaugos | Overload, Short Circuit, Over/Under Voltage |
| Darbinė temperatūra | 0–40 °C |
| Darbinė drėgmė | 10–90 % |
| Matmenys (I x P x A) | 336 x 143 x 178 mm |
| Svoris | 4.3 kg |
9. Garantija ir palaikymas
The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.
For technical support or service inquiries, please contact your local Rebel distributor or the point of purchase. Ensure you have your product model (RB-4003) and serial number (if applicable) ready when contacting support.