1. Įvadas
This manual provides essential information for the installation, operation, and maintenance of the Opengear CM8148-10G Device Server. The CM8148-10G is a robust console manager designed for data centers and enterprise networks, offering secure and reliable out-of-band management for critical infrastructure.
It facilitates remote access and management of serial console ports, ensuring business continuity even when the primary network is unavailable. This device integrates advanced security features and supports automation tools for efficient network management.
2. Produktas baigtasview
The Opengear CM8148-10G is a high-density console server, providing extensive connectivity options for various network devices. Its design emphasizes reliability, security, and ease of management.

Figure 1: Front panel of the Opengear CM8148-10G Device Server. This image displays the front panel of the Opengear CM8148-10G Device Server. It features 48 serial console ports, two USB ports, a console port, and four network uplink ports (two SFP+ and two RJ45). The device has a dark gray chassis with a red accent stripe.
Pagrindinės funkcijos:
- 16, 32, or 96-port serial console server with Smart Out-of-Band™ capabilities.
- Designed as a replacement for legacy terminal servers.
- Enables Data Center automation with Python and Docker support.
- Embedded physical security using a TPM 2.0 module.
- Dual power supplies with independent monitoring for enhanced reliability.
3. Sąranka
3.1 Išpakavimas ir patikrinimas
Carefully unpack the device server and its accessories. Inspect all components for any signs of damage. If any damage is found, contact your vendor immediately.
3.2 Fizinis įrengimas
The CM8148-10G is designed for rack mounting. Secure the device in a standard 19-inch equipment rack using the provided mounting hardware. Ensure adequate airflow around the unit for proper cooling.
3.3 Maitinimo jungtis
Connect the two power supply units to independent power sources for redundancy. Use the provided power cords. Verify that the power indicator LEDs illuminate after connection.
3.4 Tinklo jungtis
Connect the device server to your network using the appropriate Ethernet or SFP+ uplink ports. It is recommended to connect to at least two network ports for redundancy and out-of-band access.
3.5 Serial Port Connections
Connect your target devices' serial console ports to the corresponding serial ports on the CM8148-10G using straight-through cabling. The device supports auto-discovery of serial settings and port labels to simplify configuration.
4. Naudojimo instrukcijos
4.1 Pradinė prieiga
Access the device server's management interface via a web browser or SSH. Refer to the Opengear documentation for default IP addresses and login credentials. It is crucial to change default passwords immediately after initial access.
4.2 konfigūracija
Configure serial port settings, network parameters, user accounts, and security policies through the web interface. Utilize features like port auto-discovery to streamline the setup of connected devices.
4.3 Nuotolinis valdymas
Use the CM8148-10G to remotely access and manage the console ports of connected devices. This allows for troubleshooting, configuration, and monitoring of your infrastructure from any location.
4.4 Automation Features
Leverage the device's support for REST API, Docker, and Python scripting to integrate with existing automation tools and workflows. This enables advanced management and orchestration capabilities.
5. Priežiūra
5.1 Firmware atnaujinimai
Regularly check the Opengear website for firmware updates. Applying updates ensures optimal performance, security patches, and access to new features. Follow the provided instructions for a safe update process.
5.2 Valymas
Keep the device server clean and free from dust. Use a soft, dry cloth for external cleaning. Ensure ventilation openings are not obstructed to maintain proper cooling.
5.3 Aplinkosaugos aspektai
Operate the device within its specified environmental conditions (temperature, humidity) to ensure longevity and reliable performance. Avoid exposing the unit to extreme conditions or direct sunlight.
6. Problemų sprendimas
6.1 Bendros problemos
- Nėra galios: Verify power cord connections and check power sources. Ensure both power supplies are connected and their LEDs are active.
- Tinklo ryšio problemos: Check Ethernet cable connections, network configuration, and ensure the correct IP address is assigned. Verify network port status LEDs.
- Cannot Access Serial Console: Confirm serial cable type (straight-through), correct port selection, and matching serial settings (baud rate, data bits, parity, stop bits) on both the device server and the connected equipment.
- Prisijungimo problemos: Double-check username and password. If forgotten, refer to the Opengear documentation for password recovery procedures or factory reset options (use with caution).
For more detailed troubleshooting, consult the comprehensive Opengear documentation available on their official support websvetainę.
7. Specifikacijos
| Funkcija | Detalė |
|---|---|
| Prekės ženklas | „Opengear“ |
| Serija | CM8100-10G |
| Modelio numeris | CM8148-10G |
| Prekės svoris | 8 svaro |
| Gaminio matmenys (IxPxH) | 10.5 x 17.3 x 1.8 colio |
| Gamintojas | OPENGEAR |
| ASIN | B0CY59R3YY |
| Pasiekiama pirmoji data | 15 m. kovo 2024 d |
8. Garantija ir palaikymas
For information regarding the product warranty, please refer to the official Opengear warranty policy available on their website or contact your authorized Opengear reseller. Technical support and additional resources, including detailed documentation and software downloads, can be found on the Opengear support portal.
Rekomenduojama užregistruoti savo produktą, kad gautumėte atnaujinimus ir pagalbos pranešimus.