Vertiv VP5N31A0

Vertiv Geist Switched Rack PDU User Manual

Model: VP5N31A0

1. Įvadas

The Vertiv Geist Switched Rack PDU (Power Distribution Unit) model VP5N31A0 is designed to provide reliable power distribution and advanced power management capabilities within data centers and IT environments. This 1U horizontal PDU features input power monitoring and individual outlet switching, allowing for remote control and optimization of connected equipment. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your PDU.

2. Pagrindinės savybės

  • Perjungiami lizdai: Remotely turn off individual NEMA 5-20R receptacles to prevent accidental overloads or power cycle unresponsive IT equipment.
  • Input Power Monitoring: Monitor power consumption at the PDU level to optimize energy usage and capacity planning.
  • Next-Generation Interchangeable Monitoring Device (IMD): Features a 128x128 high-contrast LCD for clear display of power data. The IMD includes an internal sensor that automatically adjusts screen orientation for horizontal or vertical installations.
  • Patobulintas saugumas: Incorporates secure boot with a hardware-based trust anchor to protect data and operations.
  • Redundant Power-Sharing Port: Allows connection of two IMDs for backup power to the monitoring device in case of primary power loss.
  • Pramonės sertifikatai: UL Listed, TAA-Compliant, and RoHS certified, ensuring compliance with industry standards.
  • Patikimumas: Each unit undergoes individual testing for functionality and reliability.

3. Sąranka ir diegimas

3.1 Išpakavimas ir patikrinimas

Carefully unpack the PDU and inspect it for any signs of shipping damage. Report any damage to your supplier immediately. Ensure all components listed in the packing slip are present.

3.2 Montavimas ant stovo

The VP5N31A0 is a 1U horizontal rack-mount unit. Install the PDU into a standard 19-inch equipment rack using the provided mounting hardware. Ensure adequate airflow around the unit for proper heat dissipation.

3.3 Maitinimo jungtis

  1. Connect the PDU's NEMA L5-30P input plug to a compatible 30A, 120V power source.
  2. Ensure the power source is properly grounded and capable of supplying the required 2.8kW capacity.
  3. Verify that the power cable is securely connected and routed to prevent accidental disconnection or damage.

3.4 Įrangos prijungimas

Plug your IT equipment into the (12) NEMA 5-20R receptacles on the PDU. Distribute the load evenly across the outlets to avoid overloading any single circuit or the PDU itself.

3.5 Tinklo ryšys (neprivaloma)

For remote monitoring and control, connect the PDU's network port to your network infrastructure using a standard Ethernet cable. Refer to the IMD documentation for network configuration details.

4. Naudojimo instrukcijos

4.1 Interchangeable Monitoring Device (IMD)

The IMD provides real-time power data and access to PDU settings. The 128x128 high-contrast LCD displays information such as total power consumption (W), energy usage (KWh), apparent power (VA), and power factor (PF).

Iš arti view of the Vertiv Geist PDU's Interchangeable Monitoring Device (IMD) display, showing power readings and navigation buttons.

Figure 1: Close-up of the IMD display showing power metrics.

4.2 Remote Outlet Switching

The switched outlets allow for remote control of power to connected devices. This functionality is typically accessed via a web interface or network management system connected to the PDU's network port. Consult the PDU's network management guide for detailed instructions on configuring and using remote outlet control.

4.3 Power Cycling Equipment

In situations where IT equipment becomes unresponsive, the remote outlet switching feature can be used to power cycle individual devices without requiring physical access to the rack. This helps minimize downtime and streamline maintenance.

5. Priežiūra

5.1 Bendroji priežiūra

Keep the PDU and its surroundings clean and free from dust. Ensure that ventilation openings are not obstructed. Do not use liquid or aerosol cleaners directly on the unit.

5.2 Firmware atnaujinimai

Periodically check the Vertiv support website for available firmware updates for your PDU's IMD. Firmware updates can provide new features, performance improvements, and security enhancements. Follow the instructions provided with the firmware update package carefully.

6. Problemų sprendimas

  • Nėra elektros lizduose: Verify the PDU's input power cable is securely connected to a live power source. Check the circuit breaker on the PDU (if applicable) and the upstream circuit breaker.
  • IMD Display Not Active: Ensure the PDU is receiving power. If the IMD is modular, verify it is correctly seated.
  • Cannot Access PDU Remotely: Check network cable connections. Verify network settings (IP address, subnet mask, gateway) on the PDU and your network. Ensure there are no firewall restrictions.
  • Perkrovos indikacija: If the PDU indicates an overload, immediately reduce the connected load. Use the remote switching feature to turn off non-critical devices.
  • Unresponsive Equipment: Utilize the remote outlet switching feature to power cycle the specific unresponsive device.

7. Specifikacijos

Modelio numerisVP5N31A0
Formos faktorius1U Horizontal Rackmount
Įvesties tomastage120 voltų
Įvestis Amppakilimas30 Amps
Galios talpa2.8 kW (2800 vatų)
Įvesties kištukasNEMA L5-30P
Išvesties talpyklos(12) NEMA 5-20R
Prekės svoris18.4 svaro
Pakuotės matmenys24 x 24 x 6 colio
GamintojasVertiv
ASINB0DHMLBGHV
UPC767041044812

8. Garantija ir palaikymas

8.1 Gaminio garantija

The Vertiv Geist Switched Rack PDU VP5N31A0 comes with a standard three-year warranty. This warranty can be extended to five years if the unit is registered within 120 days of purchase. Refer to the official Vertiv webVisas garantijos sąlygas ir nuostatas rasite svetainėje.

8.2 Techninė pagalba

For technical assistance, troubleshooting, or inquiries regarding your Vertiv product, please visit the official Vertiv support website or contact their customer service. Have your product model number (VP5N31A0) and serial number ready when contacting support.

Susiję dokumentai - VP5N31A0

Preview Geist™ Intelligent Rack PDU Installer/User Guide - Vertiv
Comprehensive installer and user guide for Vertiv's Geist™ Intelligent Rack PDU, covering installation, setup, network configuration, and advanced features for data center environments.
Preview „Vertiv SmartRow 2“ infrastruktūros sprendimo diegimo / naudotojo vadovas
Šiame išsamiame vadove pateikiamos išsamios „Vertiv SmartRow 2“ infrastruktūros sprendimo diegimo, naudojimo ir priežiūros instrukcijos. Jame aprašoma visa sistema.view, features, safety instructions, power management, network configuration, and troubleshooting.
Preview Avocent DSView ir „Rack Power Manager“ programinės įrangos papildiniai: techninis biuletenis
Šiame „Vertiv“ techniniame biuletenyje pateikiamos išsamios „Avocent DS“ naudojimo gairės.View ir „Rack Power Manager“ programinės įrangos papildinius. Šie įrankiai pagerina IT infrastruktūros valdymo galimybes, leisdami vartotojams efektyviai pasiekti, stebėti ir valdyti įvairius įrenginius, įskaitant maitinimo blokus (PDU), nepertraukiamo maitinimo šaltinius (UPS), konsolių serverius ir virtualizacijos aplinkas.
Preview Vertiv Geist Watchdog 100 Installer/User Guide
Comprehensive guide for installing and using the Vertiv Geist Watchdog 100 environmental monitor, covering setup, network configuration, web interface, sensors, alarms, and safety information.
Preview Vertiv Liebert Mini-Mate Variable Capacity Condensing Unit Installer/User Guide
Comprehensive installer and user guide for the Vertiv Liebert Mini-Mate Variable Capacity Indoor Condensing Unit, covering installation, operation, maintenance, and safety for water/glycol-cooled and air-cooled models.
Preview Avocent MergePoint Unity Quick Installation Guide
This guide provides step-by-step instructions for installing the Avocent MergePoint Unity KVM over IP and serial console switch, including connecting local ports, IQ modules, target devices, network users, and optional modems or PDUs.