CPI G3C3-MN00NB

CPI Gryphon G3C3-MN00NB 6 vamzdžių MDB monetų keitiklio naudotojo vadovas

Model: G3C3-MN00NB

1. Įvadas

This manual provides detailed instructions for the installation, operation, and maintenance of the CPI Gryphon G3C3-MN00NB 6-Tube MDB Coin Changer. Designed for vending machines, this unit offers advanced coin handling capabilities and enhanced reliability.

The CPI Gryphon G3C3-MN00NB is a direct replacement for the MEI CF7512/CF7000 models, featuring next-generation patented coin sensing technology for faster and more secure coin recognition and dispensing. Its design incorporates three motors for increased reliability and continuous performance, even in the event of a motor jam. With 6 tubes, it provides 12% extra capacity, offering enhanced configuration options and increased flexibility for various vending applications.

CPI Gryphon G3C3-MN00NB 6-Tube MDB Coin Changer

Figure 1: The CPI Gryphon G3C3-MN00NB 6-Tube MDB Coin Changer. This image shows the front view of the coin changer, highlighting the CPI logo, the coin input slot, the display panel with buttons labeled A-F, and the coin tubes at the bottom with coin denominations indicated for USD currency.

2. Kas yra dėžutėje

Upon unpacking your CPI Gryphon G3C3-MN00NB, please ensure all components are present:

  • CPI Gryphon G3C3-MN00NB Coin Changer Unit
  • MDB Harness

Note: Original product box is not included with this unit.

3. Sąranka ir diegimas

Proper installation is crucial for the optimal performance of your coin changer. Follow these steps carefully:

  1. Maitinimo atjungimas: Before beginning installation, ensure the vending machine's power supply is completely disconnected to prevent electrical hazards.
  2. Montavimas: Securely mount the CPI Gryphon G3C3-MN00NB coin changer within the designated slot in your vending machine. Ensure it is stable and properly aligned with the coin entry and exit points.
  3. MDB Harness Connection: Connect the provided MDB harness to the coin changer unit. The MDB (Multi-Drop Bus) connection is a standard interface for vending machine peripherals.
  4. Vending Machine Connection: Connect the other end of the MDB harness to the corresponding MDB port on your vending machine's control board.
  5. Maitinimas: The unit requires a power supply of 34 V DC for MDB connections. Ensure your vending machine provides the correct voltage. For Executive interfaces, 12 V DC - 24 V DC is required.
  6. Pradinė konfigūracija (neprivaloma): For advanced configuration or updates, the unit supports USB connectivity. This can reduce at-machine update time. Refer to the "Configuration and Updates" section for more details.
  7. Energijos atstatymas: Once all connections are secure, restore power to the vending machine.
  8. Bandomoji operacija: Perform a test operation by inserting various coin denominations to verify proper acceptance, validation, and dispensing.

4. Operacija

The CPI Gryphon G3C3-MN00NB coin changer is designed for intuitive operation within a vending machine environment. Its primary function is to accept, validate, and dispense coins accurately.

4.1 Coin Acceptance

  • Insert coins into the designated coin slot on the vending machine.
  • The coin changer's patented sensing technology will quickly identify and validate the coin.
  • Accepted coins will be routed to the appropriate coin tube or the cash box.
  • The acceptance rate is typically >95%.

4.2 Coin Dispensing

  • When change is required, the coin changer will dispense coins from its 6 tubes.
  • The unit's three motors ensure reliable and continuous dispensing.
  • The output speed is approximately 6 coins per second.

4.3 Configuration and Updates

The coin changer supports easy updates and configuration via USB connectivity. This allows for quick software updates or adjustments to coin parameters without removing the unit from the machine.

Additionally, the unit is compatible with the CPI Synq module, enabling wireless, on-site, mobile connectivity for diagnostics, troubleshooting, and configuration. This can significantly reduce service calls and improve machine uptime.

5. Priežiūra

Regular maintenance ensures the longevity and consistent performance of your CPI Gryphon coin changer.

5.1 Valymas

  • Išorė: Išorinius paviršius nuvalykite minkšta, damp skudurėliu. Venkite abrazyvinių valiklių ar tirpiklių.
  • Coin Path: Periodically inspect the coin path for any debris, dust, or foreign objects that might obstruct coin flow. Use compressed air or a soft brush to clear any blockages.
  • Jutikliai: Gently clean coin sensing areas with a lint-free cloth to ensure accurate coin recognition.

5.2 Patikra

  • Regularly check the coin tubes for proper coin levels and ensure they are not overfilled or jammed.
  • Inspect the MDB harness and other connections for any signs of wear or damage.

5.3 Troubleshooting Tools

The CPI Gryphon supports various tools for diagnostics and maintenance:

  • STS Software: For detailed diagnostics and configuration.
  • CPI Synq: For wireless, on-site mobile connectivity, enabling diagnostics and troubleshooting.
  • Auditas: Via USB, IrDA, or Bluetooth.

6. Problemų sprendimas

This section addresses common issues you might encounter with your CPI Gryphon coin changer.

ProblemaGalima priežastisSprendimas
Coins not accepted
  • Coin path obstruction
  • Nešvarūs jutikliai
  • Incorrect coin type/denomination
  • Maitinimo klausimas
  • Clear any debris from the coin path.
  • Clean coin sensors.
  • Ensure correct coins are being used (15mm-33mm diameter, 1.2mm-3.3mm thick).
  • Patikrinkite maitinimo jungtį ir garsumątage (34V DC for MDB).
Coins not dispensed (jammed)
  • Coin tube jam
  • Variklio problema
  • Inspect coin tubes and clear any jammed coins.
  • The unit has three motors for reliability; if one jams, others may compensate. If persistent, use STS Software or CPI Synq for diagnostics.
Įrenginys nereaguoja
  • Nėra galios
  • Loose MDB connection
  • Programinės įrangos klaida
  • Check power supply to the vending machine and coin changer.
  • Ensure MDB harness is securely connected.
  • Perform a power cycle (disconnect and reconnect power).
  • Use CPI Synq for diagnostics or contact support.

7. Specifikacijos

Technical specifications for the CPI Gryphon G3C3-MN00NB Coin Changer:

  • Modelis: G3C3-MN00NB
  • Pakaitalas: MEI CF7512/CF7000
  • Coin Diameter: 15 mm - 33 mm
  • Coin Thickness: 1.2 mm - 3.3 mm
  • Input Speed: 2 coins per second
  • Output Speed: 6 coins per second
  • Interfaces Supported: Serial (MDB, MDB + Executive, MDB + BDV, JVI/VCCI, USB, Executive)
  • Darbinė temperatūra: -25°C iki 60°C
  • Galios reikalavimai:
    • 12 V DC - 24 V DC (Executive)
    • 34 V DC (MDB)
  • Tube/Coin Level Recognition System: Acoustic, Sonar
  • Palaikymo įrankiai: STS Software, CPI Synq
  • Auditas: USB, IrDA, Bluetooth
  • Acceptance Rate: >95 %
  • Matmenys (mm): 371 x 138 x 80 mm

8. Pagalba ir kontaktinė informacija

For further assistance, technical support, or warranty inquiries, please refer to the contact information provided by your vendor or the official CPI websvetainę.

Always ensure to have your model number (G3C3-MN00NB) available when contacting support.

Susiję dokumentai - G3C3-MN00NB

Preview „Gryphon“ monetų keitiklio įrengimo vadovas
„Crane Payment Innovations“ (CPI) „Gryphon“ monetų keitiklio įrengimo vadovas. Apima pradinį įjungimą, kasetės konfigūraciją, būsenos lemputes, techninės priežiūros meniu, sąrankos meniu, įrengimą, lygiavimą ir MMI sąsają.
Preview „Gryphon“ monetų keitiklio techniko vadovas: įrengimas, priežiūra ir sąranka
Išsamus CPI „Gryphon“ monetų keitiklio vadovas, kuriame išsamiai aprašomas komponentų identifikavimas, klaviatūros veikimas, diagnostikos indikatoriai, aptarnavimo ir sąrankos meniu, kasečių konfigūracija, diegimo procedūros ir lygiavimo patikrinimai.
Preview Penny Readiness Checklist: Prepare Your Business for Coin Changes
A comprehensive checklist from Crane Payment Innovations (CPI) to help businesses prepare for potential changes in penny circulation, including legal compliance, POS system updates, and operational adjustments.
Preview CPI ALIO pastaba: diegimas, naudotojo vadovas ir techninės specifikacijos
Išsamus CPI ALIO Note bekontaktės ir telemetrijos sistemos diegimo, naudojimo ir trikčių šalinimo vadovas. Apima specifikacijas, dalių sąrašą ir informaciją apie reglamentus.
Preview CPI RLX250s Spare Parts List: Oil-Cooler & Front Disk Brake Components
Comprehensive spare parts list for the CPI RLX250s motorcycle. This guide details components for the oil-cooler and front disk brake systems, essential for vehicle maintenance and repair. Find part numbers and diagrams for your CPI RLX250s.
Preview CPI Simplifi platformos naudotojo vadovas originalios įrangos gamintojams (OEM) ir VAR (VPA)
„Crane Payment Innovations“ (CPI) „Simplifi“ platformos naudotojo vadovas, kuriame išsamiai aprašoma, kaip originalios įrangos gamintojai (OEM) ir pridėtinės vertės perpardavėjai (VAR) gali prijungti, valdyti ir aktyvuoti „Alio Pro“ ir „Alio Vend“ kortelių skaitytuvus. Aptariamas įrenginių diegimas, klientų įtraukimas, turto stebėjimas ir pasirinktinė laukimo ekrano konfigūracija.