1. Įvadas
This manual provides essential information for the safe and efficient operation of the INVT GD10-0R7G-S2-B Single-Phase 230V 0.75KW VFD Frequency AC Drive. The GD10 series min-economy inverters are designed for small power OEM applications, offering advanced features such as vectorization V/F control, PID function, multi-step speed control, DC braking, and Modbus communication, all within a compact design. Please read this manual thoroughly before installation, operation, or maintenance.
2. Saugos informacija
⚠ WARNING: Risk of electric shock.
- Read this manual completely before installing or operating the device.
- Wait at least 5 minutes after disconnecting power before proceeding with any work on the unit to allow capacitors to discharge.
⚠ WARNING: Hot surfaces.
- The surfaces of the base are hot during and after operation. Do not touch the device during operation or immediately after power-off.
Only qualified personnel should perform installation, wiring, and maintenance. Ensure all local and national electrical codes are followed.
3. Produktas baigtasview

Figure 3.1: INVT GD10-0R7G-S2-B VFD Front Panel
The image displays the front panel of the INVT GD10-0R7G-S2-B VFD. It features a digital display for operational data, navigation buttons (PRG/ESC, DATA/ENT, QUICK JOG, SHIFT, UP, DOWN arrows), and dedicated RUN and STOP/RST buttons for direct control. Below the control interface, important safety warnings regarding electric shock and hot surfaces are clearly visible. The device is labeled "Goodrive10" at the bottom.
Pagrindinės funkcijos:
- V/F control mode for versatile motor speed regulation.
- Natural cooling design, suitable for environments with cotton and dust, reducing maintenance needs.
- Compact, mini structure for less installation space.
- Advanced functions including vectorization V/F control, PID function, multi-step speed control, DC braking, and Modbus communication.
4. Sąranka ir diegimas
Proper installation is critical for the safe and reliable operation of the VFD.
4.1. Montavimas:
Mount the VFD in a vertical position on a flat, non-flammable surface, ensuring adequate ventilation. Maintain sufficient clearance around the unit for heat dissipation, especially given its natural cooling design.
4.2. Laidai:
Connect the input power to the designated terminals. For the GD10-0R7G-S2-B model, ensure a single-phase 230V AC power supply. Connect the motor to the output terminals. All wiring must comply with local electrical codes and standards. Use appropriate wire gauges for the rated current.
- Įvesties tomastage: Single-phase 230V (±10%)
- Įvesties dažnis: 50Hz or 60Hz (Allowed range: 47~63Hz)
- Išėjimas ttage: Lygus įvesties tūriuitage with deviation less than 5%
- Išvesties dažnis: 50Hz/60Hz (Fluctuation range: 5%)
Refer to the detailed wiring diagrams in the complete product manual for specific terminal connections and safety grounding instructions.
5. Naudojimo instrukcijos
The VFD features an intuitive control panel for easy operation.
5.1. Valdymo skydelio funkcijos:
- Ekranas: Shows operational parameters such as frequency, current, voltage, and RPM.
- PRG/ESC: Enters/exits programming mode, or cancels current operation.
- DATA/ENT: Confirms parameter settings or enters data.
- ▲ (Up) / ▼ (Down): Navigates menus, adjusts parameter values.
- QUICK JOG: Initiates a quick jog operation (specific function depends on parameter settings).
- SHIFT: Shifts cursor position during parameter editing.
- VYKDYTI: Paleidžia variklį.
- STOP/RST: Sustabdo variklį arba atstato gedimo sąlygas.
5.2. Pagrindinė operacija:
- Ensure the VFD is properly wired and powered on.
- The display will show the current operating status or default frequency.
- Paspauskite BĖGTI mygtuką varikliui užvesti.
- Naudokite ▲ ir ▼ buttons to adjust the output frequency (and thus motor speed) if configured for panel control.
- Paspauskite STOP/RST mygtuką varikliui sustabdyti.
For advanced settings, such as PID control, multi-step speed, or Modbus communication, refer to the detailed programming section of the full INVT GD10 series manual.
6. Priežiūra
Reguliarus techninis aptarnavimas užtikrina jūsų dažnio keitiklio ilgaamžiškumą ir optimalų veikimą.
- Valymas: Laikykite dažnio keitiklių įrenginį švarų, be dulkių ir šiukšlių. Valymui naudokite minkštą, sausą šluostę. Nenaudokite skystų valiklių.
- Vėdinimas: Ensure that the ventilation openings are not obstructed to allow for proper natural cooling.
- Jungtys: Periodically check all electrical connections for tightness. Loose connections can cause overheating and malfunction.
- Aplinka: Operate the VFD within its specified environmental conditions (temperature, humidity, dust level).
- Patikra: Vizualiai patikrinkite įrenginį, ar nėra pažeidimų, spalvos pakitimų ar neįprastų kvapų.
Always disconnect power and wait for at least 5 minutes before performing any maintenance.
7. Problemų sprendimas
If you encounter issues with your VFD, consider the following basic troubleshooting steps:
- Nėra galios: Check the input power supply and all circuit breakers. Ensure connections are secure.
- Variklis neveikia: Verify that the RUN command is active. Check motor wiring and ensure the motor is not overloaded.
- Overload Trip: Reduce the load on the motor. Check for mechanical issues with the motor or driven equipment. The VFD has an overload capability of 150% of rated current for 1 minute.
- Neįprastas triukšmas / vibracija: Check motor mounting, coupling, and VFD installation.
- Rodymo klaidos: If the display shows an error code, consult the comprehensive INVT GD10 series manual for specific fault code definitions and corrective actions.
If the problem persists after basic troubleshooting, contact qualified technical support. Do not attempt to repair the unit yourself.
8. Specifikacijos
8.1. Rated Specifications (Single-Phase 230V GD10 Series)
| Modelis | Išėjimo galia (kW) | Įvesties srovė (A) | Išėjimo srovė (A) |
|---|---|---|---|
| GD10-0R2G-S2-B | 0.2 | 4.9 | 1.6 |
| GD10-0R4G-S2-B | 0.4 | 6.5 | 2.5 |
| GD10-0R7G-S2-B | 0.75 | 9.3 | 4.2 |
| GD10-1R5G-S2-B | 1.5 | 15.7 | 7.5 |
| GD10-2R2G-S2-B | 2.2 | 24 | 11 |
8.2. Techninės specifikacijos
- Valdymo režimas: V / f valdymas
- Maksimalus išėjimo dažnis: 200 Hz
- Adjustable-Speed Ratio: 0.111111111
- Perkrovos galimybė: 150% vardinės srovės 1 minutę
- Analog Input Resolution: <=20 mV
- Digital Input Resolution: <= 2ms
- Analog Input/Output: Input 0-10V or 0-20mA, Output 0-10V
8.3. Fizinės specifikacijos
- Pakuotės matmenys: 1.18 x 0.79 x 0.39 colio
- Prekės svoris: 1.76 uncijos (50 gramų)
- Modelio pavadinimas: EFZRZYJ
- Gamintojas: EFZRZYJ
9. Garantija ir palaikymas
For information regarding product warranty, please refer to the warranty card included with your purchase or contact the seller directly.
For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact the manufacturer or your authorized distributor. Provide your product model number (GD10-0R7G-S2-B) and serial number (if applicable) when seeking support.