OREiN 80/110 CFM

OREiN 3-in-1 Bathroom Fan with LED Light & Humidity Sensor Instruction Manual

Model: 80/110 CFM

1. Įvadas

Thank you for choosing the OREiN 3-in-1 Bathroom Fan. This innovative unit combines a powerful exhaust fan, an energy-efficient LED light with selectable color temperatures, and a smart humidity sensor to provide optimal ventilation and illumination for your bathroom. Designed for quiet operation and easy installation, this fan ensures a fresh and comfortable environment. Please read this manual thoroughly before installation and operation to ensure safe and proper use.

OREiN 3-in-1 Bathroom Fan with LED Light and Humidity Sensor

Image 1.1: OREiN 3-in-1 Bathroom Fan with LED Light and Humidity Sensor.

2. Saugos informacija

Always follow basic safety precautions when installing, operating, or maintaining this product to reduce the risk of fire, electric shock, or injury to persons.

3. Pakuotės turinys

Atidarius pakuotę, patikrinkite, ar yra visi komponentai ir ar jie nepažeisti:

4. Produkto ypatybės

Internal components of OREiN bathroom fan showing quiet and energy-efficient design

Image 4.1: Internal design highlighting quiet and energy-efficient components.

Graphic illustrating quiet operation of the OREiN bathroom fan with sound levels

Image 4.2: Visual representation of the fan's quiet operation at low decibel levels.

5. Sąranka ir diegimas

This section provides general guidance for installation. For detailed electrical wiring, consult a qualified electrician.

  1. Paruošimas: Ensure power is turned off at the circuit breaker before beginning any installation work.
  2. Atidarymo dydis: The fan unit requires a ceiling opening of approximately 10.24" x 9.37" (260mm x 238mm). Ensure there are no obstructions like joists in the desired installation area.
  3. Montavimas: The fast-install bracket allows for secure mounting between ceiling joists. Position the fan unit and secure the bracket using appropriate screws. The design allows for installation from below the ceiling, eliminating the need for attic access in many cases.
  4. Ortakiai: Connect the fan to standard 4-inch ducting and ensure it is vented to the outdoors.
  5. Elektros jungtis: Connect the electrical wiring according to local codes and the provided wiring diagram. The light and fan may have independent wiring for separate control.
  6. Šviesos gaubto montavimas: Once the fan unit is secured and wired, attach the LED light cover. It typically connects with spring clips for easy removal and maintenance.
Diagram showing product dimensions and installation size for OREiN bathroom fan

Image 5.1: Product dimensions and recommended installation opening size.

Illustration of easy installation process for the OREiN bathroom fan

Image 5.2: Simplified installation process showing the fan unit being placed into the ceiling opening.

6. Naudojimo instrukcijos

6.1. Humidity Sensing Mode vs. Manual Mode

The fan offers two operating modes: Manual and Humidity Sensing. You can switch between these modes by cycling the wall switch of the fan to the "OFF" position and then back to the "ON" position.

Diagram showing manual mode with red indicator and humidity sensing mode with green indicator

Image 6.1: Switching between Manual and Humidity Sensing Modes.

Illustration of humidity sensing fan operation in a bathroom

Image 6.2: How the humidity sensor automatically activates the fan.

Detailed explanation of humidity sensor operation and fan runtime

Image 6.3: Humidity sensor logic: fan turns on above 60% humidity and runs for 20 minutes after humidity drops.

6.2. Adjusting Light Color Temperature

The LED light offers three color temperature options: 3000K (Warm White), 4000K (Natural White), and 5000K (Daylight). To select the desired color temperature, locate the toggle switch on the back of the lampshade and slide it to your preferred setting.

Diagram showing 3 color temperature options for the LED light

Image 6.4: Selecting the light color temperature (3000K, 4000K, 5000K).

Bathroom scene illustrating different light color temperatures

Image 6.5: Visualizing the different light color temperatures in a bathroom setting.

6.3. Activating Night Light

To activate the 2200K night light mode, quickly cycle the light switch ON-OFF-ON within 2 seconds. This will switch the main light to the softer night light setting.

Bathroom scene with nightlight activated, showing soft 2200K illumination

Image 6.6: The 2200K night light provides subtle illumination.

Diagram showing how to activate the nightlight by cycling the switch

Image 6.7: Instructions for activating the nightlight mode.

6.4. Selecting CFM Airflow

The fan allows you to select between 80 CFM and 110 CFM airflow settings. This selection is made by sliding a toggle switch located on the fan housing. Choose the appropriate CFM based on your bathroom size and ventilation needs.

Diagram showing the CFM selection switch on the fan housing

Image 6.8: Location of the CFM selection switch (80 CFM or 110 CFM).

7. Priežiūra

Regular maintenance ensures optimal performance and longevity of your OREiN bathroom fan.

8. Problemų sprendimas

If you encounter issues with your OREiN bathroom fan, refer to the following common troubleshooting steps:

ProblemaGalima priežastisSprendimas
Ventiliatorius neįsijungia.Įrenginyje nėra maitinimo.Check circuit breaker. Ensure wall switch is ON. Verify electrical connections.
Šviesa neįsijungia.Loose connection or faulty LED module.Check the push clip connection for the light. If issue persists, contact support.
Ventiliatorius pernelyg triukšmingas.Obstruction in fan blades or motor.Turn off power and inspect fan blades for debris. Ensure proper installation and secure mounting.
Humidity sensor not activating.Incorrect mode selected or sensor malfunction.Cycle the wall switch to ensure Humidity Sensing Mode (green LED) is active. Ensure humidity in the room is above 60%.
Prasta ventiliacija / garai neišsivalo.Incorrect CFM setting, blocked ducting, or undersized fan for room.Ensure 110 CFM is selected if needed. Check ducting for blockages. Ensure proper room sealing.

If the problem persists after trying these solutions, please contact OREiN customer support.

9. Specifikacijos

FunkcijaDetalė
Prekės ženklasOREiN
Modelis80/110 CFM
Oro srautas (CFM)Selectable 80 / 110 CFM
Sones (Noise Level)0.8 / 1.0 tonų
Šviesos išvestis1500lm
Spalvų temperatūra (CCT)3000K / 4000K / 5000K pasirenkama
Naktinė lemputė CCT2200 tūkst
Maitinimo šaltinisDC
Gaminio matmenysApprox. 1"D x 1"W x 1"H (Unit), 13.1'' x 13.1'' (Light Cover)
Įdiegimo dydis10.24 colio x 9.37 colio (260 mm x 238 mm)
Ortakio skersmuo4 colio
Montavimo tipasPraplaukite kalną
Prekės svoris18.06 svaro
UPC734376313753

Note: Product dimensions provided as 1"D x 1"W x 1"H are likely placeholders and may not reflect actual physical size. Refer to installation size for accurate cutout dimensions.

Comparison of different OREiN bathroom fan models with their CFM and install sizes

9.1 vaizdas: Baigtaview of different OREiN fan models and their specifications.

10. Garantija ir palaikymas

OREiN is committed to providing high-quality products and excellent customer service. For any questions, concerns, or support needs regarding your 3-in-1 Bathroom Fan, please contact us through the following channels:

Please retain your proof of purchase for warranty claims. For detailed warranty information, refer to the product packaging or contact customer support.

Klientų aptarnavimo atstovas su ausinėmis

Image 10.1: OREiN Customer Support is available to assist you.

Susiję dokumentai - 80/110 CFM

Preview OREiN vonios kambario ištraukiamasis ventiliatorius su apšvietimu – trikčių šalinimas ir DUK
Raskite dažniausiai pasitaikančių „OREiN“ vonios kambario ištraukiamojo ventiliatoriaus su apšvietimu problemų sprendimus, įskaitant įrengimo, veikimo, triukšmo ir drėgmės problemas. Gaukite atsakymus į dažniausiai užduodamus klausimus.
Preview OREIN 80/110CFM vonios ventiliatorius su 3CCT šviesos ir drėgmės jutikliu, montavimo ir naudojimo instrukcija
Išsamus OREIN 80/110CFM vonios ventiliatoriaus su 3CCT LED šviesos ir drėgmės jutikliu įrengimo, naudojimo ir priežiūros vadovas. Apima saugos informaciją, trikčių šalinimo instrukcijas ir specifikacijas.
Preview OREIN LED įleidžiamo prožektoriaus KD3 montavimo vadovas
Išsamus OREIN LED įleidžiamo prožektoriaus KD3 (modelis OL0901430/OL0901541) įrengimo ir naudotojo vadovas. Apima saugos įspėjimus, specifikacijas, informaciją apie suderinamumą su šviesos reguliatoriumi, nuoseklias įrengimo, išėmimo ir utilizavimo instrukcijas.
Preview OREIN 110/160 CFM vonios ventiliatorius su „Bluetooth“ garsiakalbiu, 3CCT ir naktiniu apšvietimu: trumpas naudotojo vadovas
Šiame vadove pateikiamos OREIN 110/160 CFM vonios ventiliatoriaus su „Bluetooth“ garsiakalbiu, 3CCT ir naktiniu apšvietimu įrengimo ir naudojimo instrukcijos. Jame pateikiama saugos informacija, gaminio specifikacijos, naujų ir esamų konstrukcijų įrengimo veiksmai, laidų schemos, trikčių šalinimas ir nuotolinis valdymas.
Preview OREIN OL1700107 ventiliatorius su LED apšvietimu: trumpas naudotojo vadovas
Trumpas OREIN ventiliatoriaus su LED apšvietimu (OL1700107 modelis) naudotojo vadovas. Jame pateikiama saugos informacija, gaminio specifikacijos, įrengimo veiksmai, laidų schemos, priežiūros ir trikčių šalinimo instrukcijos.
Preview „OREIN Matter“ išmanusis vonios kambario ventiliatorius su šviesa, „Bluetooth“ garsiakalbiu ir drėgmės jutikliu – trumpas naudotojo vadovas
Trumpas „OREIN Matter“ išmaniojo vonios kambario ventiliatoriaus (modelis OA08004112) naudotojo vadovas. Apima įrengimo instrukcijas, specifikacijas, nuotolinio valdymo instrukcijas, trikčių šalinimo instrukcijas ir išmaniųjų namų ryšio funkcijas („Matter“, „AiDot“, „Alexa“).