1. Įvadas
This user manual provides detailed instructions for the safe and effective operation of your Hcalory TS-M Thermal Imaging Camera with Multimeter. This device integrates thermal imaging capabilities with a professional-grade digital multimeter, offering a versatile tool for diagnostics and measurement in various applications. Please read this manual thoroughly before using the device and retain it for future reference.
2. Saugos informacija
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or the equipment under test.
- Nenaudokite prietaiso, jei jis atrodo pažeistas arba jei pažeista bandymo laidų izoliacija.
- Prieš atlikdami bet kokius matavimus, įsitikinkite, kad pasirinkta tinkama funkcija ir diapazonas.
- Neviršykite jokių funkcijų maksimalių įvesties ribų.
- Būkite ypač atsargūs dirbdami su ttagesant didesnei nei 30 V AC RMS, 42 V pikinei vertei arba 60 V DC įtampai. Šie įtampų lygiaitagtai kelia šoko pavojų.
- Atjunkite grandinės maitinimą ir iškraukite visus didelės įtampos krūvius.tage capacitors before performing resistance, continuity, or diode tests.
- Use only the test leads provided or approved by Hcalory.
- Naudojimo metu laikykite pirštus už bandymo zondų apsaugų.
- Nenaudokite įrenginio sprogioje dujų, garų ar dulkių aplinkoje.
- Refer to the specifications section for detailed electrical ratings and environmental conditions.
3. Pakuotės turinys
Verify that all items listed below are present and undamaged upon opening the package. If any item is missing or damaged, contact your retailer.

3.1 pav. Pakuotės turinys
The image displays the complete contents of the Hcalory TS-M package. These include (1) an EV Toolkit (carrying case), (2) the Instruction Manual, (3) a USB Charging Cable/Probe, (4) the Thermal Imaging Multimeter 2-in-1 device, (5) Multimeter Probes, and (6) a Macro Magnetic Lens.
- Thermal Imaging Multimeter (Model TS-M)
- Multimeter Test Leads (Probes)
- USB įkrovimo laidas
- Macro Magnetic Lens
- Instrukcijų vadovas
- Carrying Case (EV Toolkit)
4. Produktas baigtasview
The Hcalory TS-M combines a high-resolution thermal imager with a full-function digital multimeter, designed for efficiency and accuracy in various diagnostic tasks. Its robust construction ensures durability in demanding environments.

Figure 4.1: Device Front and Back View
This image shows the Hcalory TS-M device from both the front and back. The front features the display screen, control buttons, and multimeter input jacks. The back includes the IR camera lens and a macro lens attachment point.
Pagrindinės funkcijos:
- Integrated Thermal Imaging: High-resolution thermal sensor for visualizing temperature differences.
- Professional Multimeter: Full range of electrical measurement functions including voltage, srovės, varžos, tęstinumo ir diodų tikrinimas.
- TISR Resolution: Enhanced thermal imaging resolution of 240x240 pixels for clearer thermal details.
- Macro Lens Capability: Magnetic macro lens for detailed thermal inspection of small components.
- Tvirtas dizainas: Built to withstand drops, dust, and water splashes, suitable for tough job sites.
- Ilgas baterijos veikimo laikas: 1500 mAh battery providing up to 7 hours of continuous operation.
5. Sąranka
5.1 Įrenginio įkrovimas
Before first use, fully charge the Hcalory TS-M. Connect the provided USB charging cable to the device's USB-C port and to a standard USB power adapter (not included) or a computer USB port. The charging indicator on the device will show charging status.

5.1 pav.: Įrenginio įkrovimas
The image illustrates the Hcalory TS-M connected via its USB-C port for charging. The display indicates a full battery and an estimated operational time of 7 hours, powered by its 1500 mAh battery.
5.2 Attaching Test Leads
For multimeter functions, insert the red test lead into the VΩ(+) jack and the black test lead into the COM(-) jack. Ensure a secure connection.
5.3 Attaching Macro Lens (Optional)
For detailed thermal inspection of small components, attach the magnetic macro lens to the designated area on the back of the device, over the IR camera lens. The magnetic attachment ensures easy installation and removal.

Figure 5.2: Macro Lens Attachment
This image demonstrates the Hcalory TS-M with its magnetic macro lens attached to the rear. The display shows a comparison of thermal images, highlighting the enhanced detail provided by the 5x magnification of the macro lens compared to 1x without it, useful for pinpoint accuracy on small components.
6. Naudojimo instrukcijos
6.1 Maitinimo įjungimas/išjungimas
Norėdami įjungti arba išjungti įrenginį, paspauskite ir palaikykite maitinimo mygtuką (paprastai pažymėtą apskritimu ir vertikalia linija).
6.2 Thermal Imaging Mode
Upon powering on, the device typically defaults to thermal imaging mode. The screen will display a thermal image of the environment. Use the navigation buttons (up, down, left, right, OK) to access menus and adjust settings such as color palettes, emissivity, and temperature units.

Figure 6.1: Thermal Imaging in Use
The image shows a user holding the Hcalory TS-M, with its screen displaying a thermal image of an engine. This illustrates the device's capability to provide immediate visual temperature data, aiding in quick problem diagnosis.
6.2.1 TISR Resolution Enhancement
The Hcalory TS-M features TISR (Thermal Imaging Super Resolution) technology, enhancing the thermal image resolution to 240x240 pixels for greater clarity. This feature can typically be toggled on or off via the device's menu settings to suit different inspection needs.

Figure 6.2: TISR Resolution Comparison
This image demonstrates the impact of TISR technology. On the left, a thermal image with TISR enabled shows a resolution of 240x240, providing significantly more detail. On the right, the same scene with TISR off displays a lower resolution of 64x64, highlighting the clarity improvement offered by the enhanced resolution feature.
6.3 Multimetro režimas
To switch to multimeter mode, use the mode selection button or navigate through the menu. Once in multimeter mode, select the desired measurement function (e.g., AC Voltage, DC ttage, Resistance, Continuity, Diode Test) using the function dial or buttons. Connect the test leads to the circuit under test as appropriate for the selected function.

Figure 6.3: Multimeter Functionality
The image shows the Hcalory TS-M in use as a multimeter, with its probes connected to a circuit board. The screen displays electrical measurement readings, demonstrating its capability for precise electrical diagnostics.
6.3.1 Common Multimeter Functions:
- ttagMatavimas (kintamoji/nuolatinė): Connect probes in parallel with the component or circuit to measure voltage.
- Atsparumo matavimas: Ensure the circuit is de-energized. Connect probes across the component to measure resistance.
- Tęstinumo testas: For checking if a circuit is complete. The device will typically emit an audible tone if continuity is detected.
- Diodo testas: For checking the functionality of diodes.
7. Priežiūra
7.1 Valymas
Nuvalykite įrenginį casing su reklamaamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning. Do not immerse the device in water.
7.2 Akumuliatoriaus priežiūra
The device contains a rechargeable lithium-ion battery. For optimal battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge it to approximately 50% every few months.
7.3 Fuse Replacement (Multimeter)
The multimeter functions are protected by internal fuses. If a current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.
8. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Įrenginys neįsijungia. | Žemas arba išsikrovęs akumuliatorius. | Įkraukite įrenginį naudodami pateiktą USB laidą. |
| Terminis vaizdas yra neryškus arba neaiškus. | Lens is dirty; TISR is off. | Clean the IR lens with a soft cloth. Enable TISR in settings. |
| Multimeter readings are incorrect or zero. | Incorrect function selected; test leads not properly connected; blown fuse. | Verify function selection. Ensure leads are securely connected. Check and replace fuse if necessary (qualified personnel only). |
| Įrenginys užstringa arba nereaguoja. | Programinės įrangos triktis. | Perform a soft reset by holding the power button for 10-15 seconds. If persistent, a factory reset may be required (refer to advanced settings). |
9. Specifikacijos
| Funkcija | Specifikacija |
|---|---|
| Modelis | TS-M |
| Prekės ženklas | KALORIJŲ |
| Šiluminė skiriamoji geba | 240x240 pixels (with TISR) |
| Temperatūros diapazonas | -68°F to 1022°F (approximately -55°C to 550°C) |
| Baterijos tipas | 12V Lithium-ion (included) |
| Baterijos talpa | 1500 mAh (5.55 vatvalandžių) |
| Veikimo laikas | Iki 7 valandų |
| Prekės svoris | 599 g |
| Pakuotės matmenys | 24.41 x 15.09 x 6.71 cm |
| Multimetro funkcijos | ttage (AC/DC), Current, Resistance, Continuity, Diode Test |
| Įtraukti komponentai | Thermal Imaging Camera with Multimeter, Test Leads, USB Cable, Macro Lens, Carrying Case, Manual |
| Kilmės šalis | Kinija |
10. Garantija ir palaikymas
For warranty information and technical support, please refer to the warranty card included with your product or visit the official Hcalory websvetainėje. Išsaugokite pirkimo kvitą kaip pirkimo įrodymą garantiniams reikalavimams.
In case of issues not covered in the troubleshooting section, or for service inquiries, please contact Hcalory customer support.