ENTTEC 73539 DIN PIXIE
Informacija apie produktą
Specifikacijos:
- Individualizuoto protokolo kūrimo vadovas
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
Produkto naudojimo instrukcijos
Įvadas:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
Sąrankos reikalavimai:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
SUDERINAMA PROGRAMA
Pasirinktinis protokolas sukuriamas šiuose ENTTEC pikselių valdikliuose:
| SKU | Produktas | Programinės įrangos versija |
| 73539 | DIN PIXIE | V2.0 arba naujesnė versija |
| 70067 | PIXELATOR MINI | V2.0 arba naujesnė versija |
| 70068 | PIXELATOR MINI MK2 | V1.0 arba naujesnė versija |
| 71521 | OCTO MK2 | V4.0 arba naujesnė versija |
| 71522 | OCTO MK3 | V1.0 arba naujesnė versija |
ĮVADAS
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- Ši funkcija leidžia vartotojams reguliuoti garsumątage. laikas, pagrįstas palaikomais protokolais, jei duomenų perdavimo būdas atitinka bet kurį iš palaikomų protokolų.
- Šiame dokumente pateikiamos sąrankos instrukcijos, kaip sukurti pasirinktinį pikselių protokolą ir patikrinti kriterijus.
NUSTATYMO REIKALAVIMAI
Norint sukurti pasirinktinį protokolą, reikia:
- Duomenų lapas: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- Įrenginys: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
PRISTATYMO PROTOKOLO KŪRIMO VADOVAS
Ši funkcija leidžia vartotojams koreguoti duomenų kiekįtage timing to meet specific protocol needs. To create a custom protocol:
- Patikrinkite suderinamo pikselių protokolo duomenų lapą.
- Eikite į įrenginio vartotojo sąsają, kad įjungtumėte pasirinktinio protokolo funkciją.
- Sureguliuokite pikselių šviestuvo duomenų kiekįtage laikas per web sąsaja pagal gamintojo duomenų lapą.
1 veiksmas: patikrinkite suderinamo protokolo duomenų lapą
- Duomenų lape patikrinkite pageidaujamo protokolo duomenų perdavimo būdą.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Labiausiai paplitęs metodas perduoda duomenis be papildomų bitų (pvz., D1-D2-D3…Dn).
Example: Informacija paimta iš WB2812B duomenų lapo
- Kai kuriuose protokoluose, pvz., TM1814, priekyje yra papildomų duomenų (pvz., C1-C2-D1-D2…Dn).
Example: Informacija paimta iš TM1814 duomenų lapo
- Labiausiai paplitęs metodas perduoda duomenis be papildomų bitų (pvz., D1-D2-D3…Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Nurodykite įrenginio palaikomą atitikimo protokolą (arba pasirinkite iš aukščiau pateiktų, pvzample) that shares the same data transmission method as your desired pixel protocol.
- Norėdami atlikti tolesnę konfigūraciją, pereikite prie 2 veiksmo.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web sąsaja
- „Google Chrome“ siūloma kaip web browser to access the OCTO/PIXELATOR MINI’s web sąsaja.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC websvetainėje www.enttec.com, kad galėtumėte atsisiųsti programą.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
Eikite į išvestį, prie kurios prijungtas norimas pikselių įtaisas. Išskleidžiamajame sąraše pasirinkite pikselių protokolą, kuris naudoja tą patį perdavimo metodą, patvirtintą 1 veiksme.
- Enable Custom protocol (Continue to Step 3)
Įjunkite žymimąjį langelį „Custom“, kad pasiektumėte duomenų kiekįtage laiko nustatymas. Atžymėkite, kad išjungtumėte pasirinktinį protokolą.
DIN PIXIE
- Prijunkite DIN PIXIE prie kompiuterio naudodami B tipo USB.
- Paleiskite EMU programinę įrangą.
- Ieškokite įrenginio ir spustelėkite aptikto DIN PIXIE Conf.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
3 veiksmas: nustatykite pasirinktinį tūrįtage laikas
- Suderinkite ttage laiko jūsų pageidaujamo protokolo duomenų lape. Pasirinktiniam protokolui reikia 4 įvesčių, kad būtų užpildyti duomenystage laiko reguliavimas:
ttage Timing Definition 0 bito didžiausias laikas (T0H) Ttag0 kodui reikalingas didelis laikas. 1 bito didžiausias laikas (T1H) Ttag1 kodui reikalingas didelis laikas. Overall Bit Time: Bendras ttage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
Iš naujo nustatyti laiką Bendras ttagtrumpas laikas, reikalingas duomenų perdavimui tarp kiekvienos duomenų partijos iš naujo nustatyti. 
- Duomenų lapas – Data voltage laiko informacija Pvzample
Iš WB2818B duomenų lapo- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage laiko intervalas.
- Užpildykite ttage laiko intervalą pasirinktiniame lauke Išvesties nustatymai.

SVARBU
- ENTTEC recommends taking the median value of the range for the start.
- Kad pakeista reikšmė įsigaliotų, vartotojas turės IŠSAUGOTI nustatymus.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
IŠVADA
- Šiame vadove parodyta, kaip nustatyti tinkintą protokolą tinkamiems ENTTEC įrenginiams, ir suteiktos techninės žinios, kaip patikrinti norimų pikselių įtaisų duomenų lapą.
- Atlikdami šiuos veiksmus, vartotojai gali sukurti pasirinktinį pikselių protokolą, kurio nėra išskleidžiamajame sąraše, nelaukdami techninės pagalbos arba naujos programinės įrangos leidimo. Jei turite klausimų ar sunku rasti reikiamos informacijos, susisiekite su mūsų draugiška pagalbos komanda vietiniuose biuruose.
DUK
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web naršyklė.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.
Dokumentai / Ištekliai
![]() |
ENTTEC 73539 DIN PIXIE [pdfNaudojimo instrukcija DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE |
