L3 Campus Stackable Managed Switch
„
Specifikacijos
- Modelis: Omada Campus Stackable L3 Managed Switch
- Front Panel: Mode Selection Button, Management Port, LED,
Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
LED - LED indikacija:
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
disconnected or not working properly) - PWR2: Green On (switch powered by PWR1 and PWR2 connected),
Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
tinkamai) - LED SYS FAN: Green On (all fans work properly), Yellow On (not
all fans work properly) - MGMT: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port) - MST: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port)
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
Produkto naudojimo instrukcijos
2 skyrius: Įrengimas
Prieš pradėdami diegimo procesą, įsitikinkite, kad turite viską
the necessary tools and follow safety precautions.
- Pakuotės turinys: Check all items mentioned in
paketą. - Saugos priemonės: Laikykitės gairių, kad
užtikrinti saugų montavimą. - Diegimo įrankiai: Gather all tools required
montavimui. - Produkto montavimas: Vykdykite žingsnis po žingsnio
instructions provided in the manual for successful
įrengimas.
3 skyrius: Prijungimas
After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.
4 skyrius: Konfigūracija
Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
poreikius.
DUK
Q: What should I do if the LED indications show an error?
A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
vadovo skyrių, kad gautumėte tolesnės pagalbos.
“`
Verslo tinklų sprendimas
Diegimo vadovas
Omada C.ampus Stackable L3 Managed Switch
Apie šį diegimo vadovą
Šiame diegimo vadove aprašomos aparatinės įrangos charakteristikos, diegimo metodai ir dalykai, į kuriuos reikia atkreipti dėmesį diegimo metu. Šis diegimo vadovas suskirstytas taip: 1 skyrius. Įvadas Šiame skyriuje aprašomi išoriniai komutatoriaus komponentai. 2 skyrius. Diegimas Šiame skyriuje paaiškinama, kaip įdiegti komutatorių. 3 skyrius. Prijungimas Šiame skyriuje paaiškinama, kaip fiziškai prijungti komutatorių. 4 skyrius. Konfigūracija Šiame skyriuje paaiškinama, kaip konfigūruoti komutatorių. A priedas. Trikčių šalinimas B priedas. Specifikacijos
Publika
Šis diegimo vadovas skirtas:
Tinklo inžinierius
Tinklo administratorius
konvencijos
· Kai kurie šiame vadove pateikti modeliai gali būti neprieinami jūsų šalyje ar regione. Informacijos apie vietinius pardavimus ieškokite adresu https://www.omadanetworks.com/.
· 2, 3 ir 4 skyriuose pateikti skaičiai yra tik demonstravimo tikslais. Jūsų jungiklis savo išvaizda gali skirtis nuo pavaizduotos.
· PoE biudžeto skaičiavimai pagrįsti laboratoriniais tyrimais. Tikrasis PoE energijos biudžetas negarantuojamas ir skirsis dėl kliento apribojimų ir aplinkos veiksnių.
· Šiame vadove naudojami konkretūs formatai ypatingiems pranešimams paryškinti. Šioje lentelėje pateikiamos šiame vadove naudojamos įspėjimų piktogramos.
Priminkite būti atsargiems. Atsargiai nurodoma galimybė, kuri gali pakenkti įrenginiui.
Priminkite, kad atkreipkite dėmesį. Užraše pateikiama naudinga informacija, kad produktas būtų geriau naudojamas.
Susijęs dokumentas
Produkto vartotojo vadovas ir CLI informacinis vadovas pateikiami atsisiuntimo centre. Norėdami gauti naujausią informaciją apie gaminį, apsilankykite oficialioje svetainėje webSvetainė: https://support.omadanetworks.com/document/.
Turinys
Chapter 1 Introduction ———————- 01
1.1 Produktas baigtasview …………………………………………………..01 1.2 Appearance……………………………………………………………..01
Chapter 2 Installation ———————- 12
2.1 Package Contents ………………………………………………….12 2.2 Safety Precautions …………………………………………………12 2.3 Installation Tools……………………………………………………..14 2.4 Product Installation ………………………………………………..14
Chapter 3 Connection ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
4 skyrius Konfigūracija ——————— 27
4.1 Konfigūracija baigtaview…………………………………………27 4.2 Standalone Mode……………………………………………………27 4.3 Controller Mode………………………………………………………28
Appendix A Troubleshooting —————- 32
Appendix B Specifications —————— 33
Omada C.ampus Stackable L3 Managed Switch
1 skyrius Įvadas
1.1 Produktas baigtasview
Sukurta įmonėms ir korporacijomsampus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. ExampTai apima tinklo kameras, belaidžio LAN prieigos taškus, IP telefonus, tinklo šakotuvus, įterptuosius kompiuterius ir kt.
1.2 Išvaizda
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Režimo pasirinkimo mygtukas
Valdymo uostas
LED
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 prievadas
10G SFP+ Slot LED
The front panel of S6500-48G6XF is shown as the following figure.
Režimo pasirinkimo mygtukas
Valdymo uostas
LED
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 prievadas
10G SFP+ Slot LED
Įvadas 01
Omada C.ampus Stackable L3 Managed Switch
LED indikacija
PWR1*
PWR2
Žalia
Išjungta
Žalia
Įjungta geltona**
Išjungta
Žalia
Išjungta
Išjungta
Indikacija
Jungiklis maitinamas PWR1. PWR2 atjungtas arba veikia netinkamai.
Jungiklis maitinamas PWR1. PWR1 ir PWR2 yra prijungti.*
Jungiklis maitinamas PWR2. PWR1 atjungtas arba veikia netinkamai.
Jungiklis išjungtas arba PWR1 ir PWR2 veikia netinkamai.
LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Kai dega STK šviesos diodas)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***
Indikacija
Mirksi: jungiklis veikia tinkamai. Įjungta arba išjungta: jungiklis veikia netinkamai.
Šviečia žaliai: visi ventiliatoriai veikia tinkamai. Geltona šviečia: ne visi ventiliatoriai veikia tinkamai.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Šviečia žaliai: veikia 1000 Mbps greičiu, bet neveikia. Mirksi žaliai: veikia 1000 Mbps greičiu ir perduoda arba gauna duomenis. Geltona šviečia: veikia 10 Mbps / 100 Mbps greičiu, bet neveikia. Mirksi geltonai: veikia 10 Mbps/100 Mbps greičiu ir perduoda arba priima duomenis. Išjungta: joks įrenginys nesusietas su atitinkamu prievadu.
Įjungta: prievado numeris rodo vieneto ID kamino topologijoje.
Žalia įjungta: veikia 10 Gb/s greičiu, bet neveikia. Mirksi žaliai: veikia 10 Gbps greičiu ir perduoda arba gauna duomenis. Geltona šviečia: veikia 1 Gbps greičiu, bet neveikia. Mirksi geltonai: veikia 1 Gbps greičiu ir perduoda arba gauna duomenis. Išjungta: joks įrenginys nesusietas su atitinkamu prievadu.
*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Kai ir PWR1, ir PWR2 veikia tinkamai, o jungiklis maitinamas iš PWR1, LED PWR10 (geltonas) užgęsta po 20–2 sekundžių, kai PWR2 yra atjungtas.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
02 Įvadas
Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.
Režimo pasirinkimo mygtukas
Valdymo uostas
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 prievadas
10G SFP+ Slot LED
S6500-48GP6XF priekinis skydelis parodytas toliau pateiktame paveikslėlyje.
Režimo pasirinkimo mygtukas
Valdymo uostas
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 prievadas
10G SFP+ Slot LED
The front panel of S6500-24M4Y is shown as the following figure.
Režimo pasirinkimo mygtukas
Valdymo uostas
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 prievadas
25G SFP28 Slot LED
The front panel of S6500-24MPP4Y is shown as the following figure.
Režimo pasirinkimo mygtukas
Valdymo uostas
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 prievadas
25G SFP28 Slot LED
Įvadas 03
Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.
Režimo pasirinkimo mygtukas
Valdymo uostas
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 prievadas
The front panel of S6500-48MPP6Y is shown as the following figure.
25G SFP28 Slot LED
Režimo pasirinkimo mygtukas
Valdymo uostas
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 prievadas
25G SFP28 Slot LED
LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST
Indikacija
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Mirksi: jungiklis veikia tinkamai. Įjungta arba išjungta: jungiklis veikia netinkamai.
Šviečia žaliai: visi ventiliatoriai veikia tinkamai. Geltona šviečia: ne visi ventiliatoriai veikia tinkamai.
Įjungta: likusi PoE galia yra 7 W. Mirksi: likusi PoE galia išlieka 7 W, kai šis šviesos diodas dega 2 minutes. Išjungta: likusi PoE galia yra > 7 W.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
04 Įvadas
Omada C.ampus Stackable L3 Managed Switch
LED
Indikacija
Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)
Šviečia žaliai: veikia 1000 Mbps greičiu, bet neveikia. Mirksi žaliai: veikia 1000 Mbps greičiu ir perduoda arba gauna duomenis. Geltona šviečia: veikia 10 Mbps / 100 Mbps greičiu, bet neveikia. Mirksi geltonai: veikia 10 Mbps/100 Mbps greičiu ir perduoda arba priima duomenis. Išjungta: joks įrenginys nesusietas su atitinkamu prievadu.
Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)
Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Kai dega STK šviesos diodas)
Įjungta: prievado numeris rodo vieneto ID kamino topologijoje.
Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Kai dega PoE šviesos diodas)
Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port
Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***
Žalia įjungta: veikia 10 Gb/s greičiu, bet neveikia. Mirksi žaliai: veikia 10 Gbps greičiu ir perduoda arba gauna duomenis. Geltona šviečia: veikia 1 Gbps greičiu, bet neveikia. Mirksi geltonai: veikia 1 Gbps greičiu ir perduoda arba gauna duomenis. Išjungta: joks įrenginys nesusietas su atitinkamu prievadu.
Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Įvadas 05
Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Valdymo uostas
LED
Console Port USB3.0 Port
(RJ45/Type-C)
Režimo pasirinkimas
Mygtukas
10G SFP+ Slot (Port 1-26)
The front panel of S7500-48XF4C is shown as the following figure.
LED 25G SFP28 Slot (Port 27-32)
Režimo pasirinkimo mygtukas
Valdymo uostas
LED Console Port USB3.0 Port (Type-C/RJ45)
10G SFP+ Slot (Port 1-48)
The front panel of S7500-24Y4C is shown as the following figure.
100G QSFP28 Slot LED (Port 49-52)
Valdymo uostas
LED
USB3.0 prievadas
Konsolės prievadas
(RJ45/Type-C)
Režimo pasirinkimo mygtukas
25G SFP28 lizdas
LED
(1-24 prievadas)
The front panel of S7500-48Y8C is shown as the following figure.
100G QSFP28 Slot (Port 25-28)
LED Mode Selection Button
25G SFP28 Slot (Port 1-48)
06 Įvadas
100G QSFP28 Slot (Port 49-56)
Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.
Režimo pasirinkimo mygtukas
Valdymo prievado šviesos diodas
USB3.0 prievadas
Console Port (Type-C/RJ45)
100G QSFP28 lizdas
LED
Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.
LED Indication LED
PWR1* PWR2
SYS FAN
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Kai dega SPD šviesos diodas)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)
Indikacija
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Mirksi: jungiklis veikia tinkamai. Įjungta arba išjungta: jungiklis veikia netinkamai.
Žalia: visi ventiliatoriai veikia tinkamai. Geltona: ne visi ventiliatoriai veikia tinkamai.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
Pastaba:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Žalia įjungta: veikia 10 Gb/s greičiu, bet neveikia. Mirksi žaliai: veikia 10 Gbps greičiu ir perduoda arba gauna duomenis. Geltona šviečia: veikia 1 Gbps greičiu, bet neveikia. Mirksi geltonai: veikia 1 Gbps greičiu ir perduoda arba gauna duomenis. Išjungta: joks įrenginys nesusietas su atitinkamu prievadu.
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Įvadas 07
Omada C.ampus Stackable L3 Managed Switch
LED
Indikacija
Port 27-32 of S7500-26XF6Y ***
(Kai dega SPD šviesos diodas)
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)
Žalia įjungta: veikia 100 Gb/s greičiu, bet neveikia. Mirksi žaliai: veikia 100 Gbps greičiu ir perduoda arba gauna duomenis. Geltona šviečia: veikia 40 Gbps greičiu, bet neveikia. Mirksi geltonai: veikia 40 Gbps greičiu ir perduoda arba gauna duomenis. Išjungta: joks įrenginys nesusietas su atitinkamu prievadu.
Pastaba:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)
Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Kai dega STK šviesos diodas)
Įjungta: prievado numeris rodo vieneto ID kamino topologijoje.
*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Management Port Designed to connnect the device for management through web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.
08 Įvadas
Omada C.ampus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature
Modelis
1000 mln
2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB
RJ45 Port RJ45 Port Slot
Lizdas
Lizdas
Uostas
Uostas Uostas
S6500-24G4XF
24
/
4
/
/
S6500-48G6XF
48
/
6
/
/
S6500-24GP4XF
24
/
4
/
/
S6500-48GP6XF
48
/
6
/
/
S6500-24M4Y
/
24
/
4
/
S6500-24MPP4Y
/
24
/
4
/
S6500-48M6Y
/
48
/
6
/
S6500-48MPP6Y
/
48
/
6
/
S7500-26XF6Y
/
/
26
6
/
S7500-48XF4C
/
/
48
/
4
S7500-24Y4C
/
/
/
24
4
S7500-48Y8C
/
/
/
48
8
S7500-32C
/
/
/
/
32
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot Grounding Terminal Power Socket
Locking Strap Slot
Pastaba: PWR1 yra pagrindinis maitinimo šaltinis ir jam teikiama pirmenybė prieš PWR2.
Įvadas 09
Omada C.ampus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensingtono saugos lizdas
LED
Įžeminimo terminalas
Maitinimo modulis
LED
Locking Strap Slot
Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Įžeminimo terminalas
LED
Power Supply Module Locking Strap Slot
LED
Kensingtono saugos lizdas
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.
S7500-48Y8C galinis skydelis parodytas toliau pateiktame paveikslėlyje. Paveikslėlis skirtas tik demonstraciniams tikslams. Jūsų jungiklio išvaizda gali skirtis nuo pavaizduoto.
Įžeminimo terminalas
LED
LED
Užrakinimo dirželis
Lizdas
Maitinimo modulis
10 Įvadas
ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED
Omada C.ampus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
LED šviesos diodas
Locking Strap Slot
Power Supply Module Kensington Security Slot
Įžeminimo terminalas
LED
Locking Strap Slot
Maitinimo modulis
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.
Įvadas 11
Omada C.ampus Stackable L3 Managed Switch
2 skyrius Įrengimas
2.1 Pakuotės turinys
Įsitikinkite, kad pakuotėje yra šie elementai. Susisiekite su savo platintoju, jei kuri nors iš išvardytų elementų yra pažeista arba jų trūksta. Skaičiai skirti tik demonstravimui. Faktinės prekės savo išvaizda ir kiekiu gali skirtis nuo pavaizduotų.
Perjungti
Maitinimo laidas ir konsolės laidas
Diegimo vadovas
Verslo tinklų sprendimas
Diegimo vadovas
Omada C.ampus Stackable L3 Managed Switch
Montavimo laikikliai, varžtai ir guminės kojelės
2.2 Saugos priemonės
Kad išvengtumėte prietaiso sugadinimo ir kūno sužalojimų dėl netinkamo naudojimo, laikykitės šių taisyklių.
Saugos priemonės Montavimo metu išjunkite maitinimą. Dėvėkite nuo ESD apsaugantį riešo dirželį ir įsitikinkite, kad jis gerai liečiasi su oda ir yra
gerai įžemintas. Naudokite tik prie jungiklio pridėtą maitinimo laidą. Įsitikinkite, kad maitinimo įtampatage atitinka specifikacijas, nurodytas galiniame skydelyje
jungiklis. Įsitikinkite, kad jungiklis sumontuotas gerai vėdinamoje aplinkoje, o jo ventiliacijos anga nėra
užblokuotas. Neatidarykite ir nenuimkite jungiklio dangtelio. Prieš valydami įrenginį, atjunkite maitinimą. Nevalykite jo vandeninga šluoste ir niekada
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Svetainės reikalavimai
Temperatūra/Drėgmė
12 diegimas
Omada C.ampus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Ant jungiklio susikaupusias dulkes gali sugerti statinė elektra ir dėl to prastas kontaktas su metaliniais kontaktiniais taškais. Buvo imtasi tam tikrų priemonių, kad prietaisas būtų apsaugotas nuo statinės elektros energijos, tačiau per stipri statinė elektra gali mirtinai pažeisti vidinės plokštės elektroninius elementus. Kad išvengtumėte statinės elektros poveikio jungiklio veikimui, didelę reikšmę skirkite šiems dalykams: Reguliariai valykite dulkes iš įrenginio ir palaikykite švarų patalpų orą. Įrenginį laikykite gerai įžemintą ir įsitikinkite, kad buvo perkelta statinė elektra. Elektromagnetiniai trukdžiai
Elektroninius elementus, įskaitant įrenginio talpą ir induktyvumą, gali paveikti išoriniai trukdžiai, pvz., laidoji spinduliuotė per talpos jungtį, induktyvumo jungtį ir varžos jungtį. Kad sumažintumėte trikdžius, būtinai imkitės šių priemonių: Naudokite maitinimo šaltinį, kuris gali efektyviai filtruoti elektros tinklo trikdžius. Laikykite įrenginį atokiai nuo aukšto dažnio ir stiprios srovės įrenginių, tokių kaip radijo siųstuvas
stotis. Jei reikia, naudokite elektromagnetinį ekranavimą. Apsauga nuo žaibo
Įdiegimas 13
Omada C.ampus Stackable L3 Managed Switch
Itin didelis tūristage srovės gali susidaryti akimirksniu žaibuojant, o oras elektros išlydžio kelyje gali akimirksniu įkaisti iki 20,000 XNUMX °C. Kadangi ši momentinė srovė yra pakankamai stipri, kad sugadintų elektroninius prietaisus, reikėtų imtis efektyvesnių apsaugos nuo žaibo priemonių. Įsitikinkite, kad stovas ir prietaisas yra gerai įžeminti. Įsitikinkite, kad maitinimo lizdas turi gerą kontaktą su žeme. Laikykite pagrįstą kabelių sistemą ir venkite žaibo. Naudokite signalą SPD (apsauginis nuo viršįtampio įtaisas), kai laidai jungiami lauke.
Pastaba: Išsamias žaibosaugos priemones rasite žaibosaugos vadove, kurį rasite adresu: https://support.omadanetworks.com/r/1004/. Montavimo vieta
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Diegimo įrankiai
„Phillips“ atsuktuvas, ESD prevencinis riešo apvyniojimo kabelis
Pastaba: šie įrankiai nėra įtraukti į mūsų gaminį. Jei reikia, galite juos įsigyti atskirai.
2.4 Gaminio montavimas
Jungiklis sukurtas su šilumos išsklaidymo iš priekio į galą funkcija. Kai jis veikia, oras cirkuliuoja taip, kaip parodyta žemiau. Kad šiluma būtų geriau išsklaidyta, įrenkite įrenginį gerai vėdinamoje aplinkoje ir aplink įrenginį palikite 5–10 cm tarpus.
14 diegimas
2-1 pav
Oro cirkuliacija
Omada C.ampus Stackable L3 Managed Switch
Darbalaukio diegimas
Norėdami įdiegti įrenginį darbalaukyje, atlikite šiuos veiksmus:
1. Pastatykite prietaisą ant lygaus paviršiaus, kuris yra pakankamai stiprus, kad su visais priedais atlaikytų visą prietaiso svorį.
2. Nuimkite lipnius pagrindinius popierius nuo guminių kojų.
3. Pritvirtinkite gumines kojeles prie įrenginio apačios, kad jis neslystų, kai jis yra ant darbastalio.
2-2 pav
Darbalaukio diegimas
Įrenginio apačioje esanti įpjova
Stovo montavimas
Pakuotėje yra 6 poros skirtingų stovo tvirtinimo kronšteinų, jų nuotraukos pavaizduotos žemiau ir gali skirtis nuo faktinių gaminių.
2-3 pav
Montavimo laikikliai
Screw Hole Group 2
Bracket D Bracket C Bracket B Bracket A
Screw Hole Group 1
Screw Hole Group 3
Laikiklis F
Screw Hole Group 4-2 (for device with 420mm depth)
Screw Hole Group 5
Sraigtinė skylė
4-1 grupė
Screw Hole Group 4-3
(for device with 380mm depth)
(for device with
460mm depth)
Laikiklis E
Įdiegimas 15
Omada C.ampus Stackable L3 Managed Switch
Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:
Metodas
Demonstracija
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)
Rack Distance
(For device with a depth of 380mm)
Rack Distance
(For device with a depth of 420mm)
Rack Distance
(For device with a depth of 460mm)
498-640mm 538-680mm 578-720mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)
477-498mm 517-538mm 557-578mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)
429-477mm 469-517mm 509-557mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)
410-429mm 450-469mm 490-509mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)
357-410mm 397-450mm 437-490mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)
282-410mm 322-450mm 362-490mm
16 diegimas
Omada C.ampus Stackable L3 Managed Switch
Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)
555-936mm 555-936mm 555-936mm
Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)
743-1121mm 743-1121mm 743-1121mm
Norėdami įdiegti įrenginį, vadovaukitės toliau pateiktomis instrukcijomis:
1. Attach the M6 nuts to the racks.
2-4 pav
Securing M6 Nuts
×8
2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.
2-5 pav
Installing Brackets on Racks
or
3. Attach the brackets A & D/F to the switch with the provided M3 screws.
Įdiegimas 17
Omada C.ampus Stackable L3 Managed Switch
2-6 pav
Installing Brackets on Switch
4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.
2-7 pav
Installing Switch on Racks
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.
18 diegimas
Omada C.ampus Stackable L3 Managed Switch
Maitinimo modulio montavimas
S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.
2-8 pav
Appearance of the Power Supply Module
Kintamosios srovės maitinimo laido jungtis
VENTILIATORIUS
Laikikliai
Extraction Handle
LED
Locking Strap Slot Release Handle
Jei reikia pridėti dar vieną maitinimo modulį, atlikite šiuos veiksmus:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Press the extraction handle of the module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
3. Release the extraction handle to fix the power supply module in place.
2-9 pav
Maitinimo modulio diegimas
Atlaisvinimo rankena
Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
Įdiegimas 19
Omada C.ampus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap
Jei reikia išimti maitinimo modulį, atlikite šiuos veiksmus:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Ventiliatoriaus modulio montavimas
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
2-11 pav. Ventiliatoriaus modulio išvaizda
LED
20 diegimas
Extraction Handle Retainer Clips Release Handle
Omada C.ampus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded. 2. Press the extraction handle of the module with one hand, and pull the extraction handle until the
module completely comes out of the chassis.
2-12 pav. Pažeisto ventiliatoriaus modulio pašalinimas
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Įdiegimas 21
Omada C.ampus Stackable L3 Managed Switch
3 skyrius Prisijungimas
3.1 Ethernet prievadas
Prijunkite jungiklio Ethernet prievadą prie kompiuterio RJ45 kabeliu, kaip parodyta šiame paveiksle.
3-1 pav
RJ45 prievado prijungimas
RJ45 uostas
RJ45 kabelis
3.2 10G SFP+/25G SFP28/100G QSFP28 Slot
The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module
3-2 pav
Inserting the Fiber Module
Slot Fiber Module
3.3 Konsolės prievadas
CLI (komandinės eilutės sąsaja) leidžia valdyti komutatorių, todėl CLI galite įkelti prijungę kompiuterius arba terminalus prie komutatoriaus konsolės prievado kabeliu (RJ45 konsolės kabelis yra pridėtas, o C tipo kabelis nėra pridėtas).
Prijunkite įrenginio RJ45 konsolės prievadą su kompiuteriu konsolės kabeliu, kaip parodyta toliau pateiktame paveikslėlyje.
22 Ryšys
3-3 pav
Konsolės (RJ45) prievado prijungimas
Omada C.ampus Stackable L3 Managed Switch
Prijunkite įrenginio C tipo konsolės prievadą su kompiuteriu C tipo kabeliu (nepridedamas), kaip parodyta toliau pateiktame paveikslėlyje.
3-4 pav
Konsolės (USB) prievado prijungimas
Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Patikrinkite diegimą
Baigę montuoti, patikrinkite šiuos dalykus: Aplink įrenginį turi būti 5–10 cm laisvos vietos vėdinimui ir užtikrinkite oro srautą.
yra adekvatus. ttage maitinimo blokas atitinka įvesties tūrio reikalavimątagįrenginio e. Maitinimo lizdas, įrenginys ir stovas yra gerai įžeminti. Įrenginys tinkamai prijungtas prie kitų tinklo įrenginių.
23 jungtis
Omada C.ampus Stackable L3 Managed Switch
3.5 Įjungimas
Prijunkite pateikto maitinimo laido moterišką jungtį į įrenginio maitinimo lizdą, o teigiamą jungtį įkiškite į maitinimo lizdą, kaip parodyta toliau pateiktame paveikslėlyje. Įsitikinkite, kad ttage maitinimo blokas atitinka įvesties tūrio reikalavimątage (100-240 V~ 50/60 Hz).
3-5 pav
Prijungimas prie maitinimo šaltinio
Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.
3.6 Inicializavimas
Įjungus įrenginį, jis pradeda „Power-On“ savikontrolę. Siekiant užtikrinti, kad prietaisas tinkamai veiktų, automatiškai atliekama keletas bandymų. Per šį laiką jo LED indikatoriai reaguos tokia tvarka:
1. PWR LED indikatorius užsidega nuolat. Visų prievadų SYS šviesos diodas ir LED indikatoriai neužsidega.
2. Maždaug po vienos minutės visų prievadų SYS šviesos diodas ir LED indikatoriai akimirksniu sumirksės ir tada išsijungs.
3. Po kelių sekundžių mirksi SYS šviesos diodo indikatorius, kuris parodo sėkmingą inicijavimą.
3.7 Stacko topologija
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:
Perjungti
Suderinamas (-i) modelis (-iai)
Kiekis
S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
24 Ryšys
Omada C.ampus Stackable L3 Managed Switch
S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S7500-26XF6Y S7500-26XF6Y
S7500-48XF4C S7500-48XF4C
S7500-24Y4C S7500-24Y4C
S7500-48Y8C S7500-48Y8C
S7500-32C
S7500-32C
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
Skirtingiems scenarijams yra trys kamino topologijos struktūros. Sukurkite tinkamą topologiją pagal savo poreikius:
1. Grandinės topologija: grandinės topologija yra gana paprasta ir nereikalauja kabelio ryšio tarp pirmojo ir paskutinio įrenginio. Jis tinka krovimui dideliais atstumais, tačiau jo patikimumas yra palyginti mažas.
3-6 pav
Grandinės topologija
2 krovimo prievadų grupė
1 krovimo prievadų grupė
…
2. Žiedo topologija: žiedo topologija yra patikimesnė, palyginti su grandinės topologija. Kai viena iš žiedo topologijos grandinių yra atjungta, žiedo topologija tampa grandinės topologija, tačiau visa kamino sistema vis tiek gali veikti normaliai. Žiedo topologija reikalauja kabelio jungties tarp pirmojo ir paskutinio bloko, todėl jis netinka sukrauti dideliais atstumais.
3-7 pav
Žiedo topologija
2 krovimo prievadų grupė
1 krovimo prievadų grupė
…
25 jungtis
Omada C.ampus Stackable L3 Managed Switch
3. Žvaigždžių topologija: Žvaigždžių topologija sujungia jungiklius su centriniu pagrindiniu komutatoriumi, todėl gali žymiai padidinti duomenų persiuntimo tarp narių komutatorių spartą, tuo pačiu užtikrinant vieningą valdymą.
3-8 pav
Žvaigždžių topologija
2 krovimo prievadų grupė
3 krovimo prievadų grupė
1 krovimo prievadų grupė
…
Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
26 Ryšys
Omada C.ampus Stackable L3 Managed Switch
4 skyrius Konfigūracija
4.1 Konfigūracija baigtaview
Jungiklis palaiko dvi konfigūracijos parinktis:
Atskiras režimas: konfigūruokite ir valdykite jungiklį atskirai. Valdiklio režimas: konfigūruokite ir valdykite tinklo įrenginius centralizuotai. Rekomenduojama
didelio masto tinklas, kurį sudaro masiniai įrenginiai, tokie kaip prieigos taškai, jungikliai ir šliuzai.
Pastaba: pakeitus jungiklį iš autonominio režimo į valdiklio režimą, jungiklio konfigūracijos bus prarastos. Norėdami gauti daugiau informacijos, žr. susijusius dokumentus mūsų pareigūno atsisiuntimo centre webSvetainė: https://support.omadanetworks.com/product/.
4.2 Atskiras režimas
Atskirame režime naudokite kompiuterį, kad sukonfigūruotumėte ir valdytumėte jungiklį naudodami GUI (grafinę vartotojo sąsają) arba CLI (komandinės eilutės sąsają).
4-1 pav
Topologija autonominiam režimui
Perjungti
PC
Naudojant GUI
1. Norėdami patekti į jungiklio valdymo puslapį, įsitikinkite, kad jungiklis ir kompiuteris yra tame pačiame potinklyje. Atidarykite naršyklę ir adreso lauke įveskite jungiklio IP adresą, tada paspauskite klavišą Enter.
Jei komutatorius gauna IP adresą iš DHCP serverio (paprastai šliuzo), suraskite komutatoriaus IP adresą DHCP serveryje.
Jei ne, naudokite numatytąjį IP adresą 192.168.0.1, kad paleistumėte jungiklio valdymo puslapį.
2. Pirmą kartą prisijungdami nustatykite vartotojo vardą ir slaptažodį, kad geriau apsaugotumėte savo tinklą ir įrenginius. Po to sistema automatiškai nukreips jus atgal į prisijungimo sąsają, kad patvirtintumėte savo tapatybę naudodami naujai sukurtus prisijungimo duomenis.
3. Po sėkmingo prisijungimo pasirodys pagrindinis puslapis. Galite spustelėti viršutinėje ir kairėje pusėje esančius meniu, kad sukonfigūruotumėte atitinkamas funkcijas.
Išsamios konfigūracijos ieškokite Vartotojo vadove ir CLI vadove. Vadovus galite rasti mūsų pareigūno atsisiuntimo centre webSvetainė: https://support.omadanetworks.com/product/.
CLI naudojimas Nustatykite Telnet arba SSH ryšį, kad galėtumėte pasiekti jungiklį per CLI.
Konfigūracija 27
Omada C.ampus Stackable L3 Managed Switch
Norėdami pasiekti jungiklį, naudokite konsolės prievadą. Kai naudojate konsolės prievadą, kompiuteryje paleiskite terminalo emuliacijos programą (pvz., „Hyper Terminal“) ir sukonfigūruokite terminalo emuliavimo programą taip:
Perdavimo sparta 38400 bps
8 duomenų bitai
Lygumas Nėra
Stop bitai 1
Srauto valdymas Nėra
Išsamios konfigūracijos ieškokite Vartotojo vadove ir CLI vadove. Vadovus galite rasti mūsų pareigūno atsisiuntimo centre webSvetainė: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.
4.3 Valdiklio režimas
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Pro Hardware Controller (C5300)
Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).
4-2 pav
Manage the network via Omada Pro Hardware Controller (C5300)
Šliuzo jungiklis
Omada Pro Hardware Controller (C5300) EAP
28 konfigūracija
EAP
EAP
Klientai
Omada C.ampus Stackable L3 Managed Switch
Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.
1. Raskite šliuzo IP adresą. Atidarykite komandų eilutę savo kompiuteryje ir įveskite „ipconfig“. Rezultatų sąraše raskite numatytąjį šliuzą, kuris taip pat yra šliuzo IP adresas.
2. Paleiskite a web naršyklėje ir įveskite šliuzo IP adresą. Prisijunkite prie šliuzo web puslapį. Tada eikite į Tinklas > LAN > DHCP klientų sąrašas, kad surastumėte savo valdiklio IP adresą pagal jo MAC adresą.
3. Adreso juostoje įveskite savo valdiklio IP adresą, kad jį atidarytumėte web puslapį.
4. On the Omada Pro Controller’s web puslapyje, vadovaukitės vedliu, kad užbaigtumėte greitą sąranką.
5. Atlikus greitą sąranką, pasirodo prisijungimo puslapis. Įveskite sukurtą vartotojo vardą ir slaptažodį ir spustelėkite Prisijungti. Tada galėsite toliau konfigūruoti valdiklį.
6. Jei norite valdyti įrenginius nuotoliniu būdu, atlikite šiuos veiksmus:
a. Įsitikinkite, kad jūsų valdiklyje įgalinta prieiga prie debesies. Pagal numatytuosius nustatymus prieiga prie debesies įjungta. Įsitikinkite, kad debesies šviesos diodas mirksi lėtai.
b. Paleisti a web naršyklę ir adreso juostoje įveskite https://omada.tplinkcloud.com. Norėdami prisijungti, įveskite savo TP-Link ID ir slaptažodį. Spustelėkite + Pridėti valdiklį ir pasirinkite Aparatūros valdiklis, kad pridėtumėte valdiklį. Tada galite toliau konfigūruoti valdiklį.
For more details, refer to the Installation Guide of C5300.
Per Omada Pro programinės įrangos valdiklį
Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.
4-3 pav
Tvarkykite tinklą naudodami „Omada Pro“ programinės įrangos valdiklį
Vartai
Perjungti
Valdiklis
Omada Pro Software Controller AP
AP
AP
veikia pagrindiniame kompiuteryje
Klientai
Konfigūracija 29
Omada C.ampus Stackable L3 Managed Switch
1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web puslapį. Jei ne, spustelėkite Paleisti naršyklę, kad tvarkytumėte tinklą.
2. On the Omada Pro Controller’s web puslapyje, vadovaukitės vedliu, kad užbaigtumėte greitą sąranką.
3. Atlikus greitą sąranką, pasirodo prisijungimo puslapis. Įveskite sukurtą vartotojo vardą ir slaptažodį ir spustelėkite Prisijungti. Tada galėsite toliau konfigūruoti valdiklį.
4. Jei norite valdyti įrenginius nuotoliniu būdu, atlikite šiuos veiksmus:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web puslapyje, eikite į Nustatymai > Prieiga prie debesies, kad įgalintumėte prieigą prie debesies ir susietumėte savo TP-Link ID. Jei jį nustatėte greitosios sąrankos metu, praleiskite šį veiksmą.
b. Paleisti a web naršyklę ir adreso juostoje įveskite https://omada.tplinkcloud.com. Norėdami prisijungti, įveskite savo TP-Link ID ir slaptažodį. Pasirodys valdiklių, susietų su jūsų TP-Link ID, sąrašas. Tada galite spustelėti Paleisti ir toliau konfigūruoti valdiklį.
Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.
Per Omada Pro debesimis pagrįstą valdiklį
„Omada Pro Cloud-Based Controller“ yra gera alternatyva, nereikia įdiegti programinės įrangos valdiklio kompiuteryje.
Licencijas reikia įsigyti papildomai.
4-4 pav
Tvarkykite tinklą naudodami „Omada Pro“ debesimis pagrįstą valdiklį
„Omada Cloud“
Vartai
Perjungti
AP
AP
AP
AP
Klientai
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with
your TP-Link ID.
30 konfigūracija
Omada C.ampus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
you can launch the controller to adopt and manage devices. * Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official webSvetainė: https://support.omadanetworks.com/product/.
Konfigūracija 31
Omada C.ampus Stackable L3 Managed Switch
A priedas Trikčių diagnostika
Q1. Ką daryti, jei pamiršau jungiklio vartotojo vardą ir slaptažodį?
1. Prijunkite kompiuterio konsolinį prievadą prie jungiklio konsolės prievado ir atidarykite terminalo emuliavimo programą.
2. Išjunkite maitinimą ir vėl įjunkite jungiklį. Atlikite terminalo emuliacijos programos nurodytą veiksmą, kad pasiektumėte bootUtil meniu. Veiksmas skiriasi priklausomai nuo produkto. Galimi veiksmai išvardyti toliau: · Paspauskite bet kurį klavišą, kad sustabdytumėte automatinį paleidimą. · Paspauskite CTRL-B, kad pasiektumėte bootUtil meniu.
3. Bus parodytas „bootUtil“ meniu. Įveskite skaičių 6, kad pasirinktumėte parinktį „Slaptažodžio atkūrimas“, ir įveskite Y, kad ištrintumėte visus vartotojus ir slaptažodžius. Tada galėsite iš naujo nustatyti vartotojo vardą ir slaptažodį.
2 klausimas. Kodėl PWR šviesos diodas veikia neįprastai? PWR / maitinimo šviesos diodas turėtų šviesti, kai maitinimo sistema veikia normaliai. Jei PWR / maitinimo šviesos diodas veikė neįprastai, atlikite šiuos veiksmus:
1. Įsitikinkite, kad maitinimo laidas tinkamai prijungtas ir maitinimo kontaktas normalus. 2. Įsitikinkite, kad garsumastage maitinimo blokas atitinka įvesties tūrio reikalavimątage iš
jungiklis.
Q3. Ką daryti, jei negaliu pasiekti web valdymo puslapis? Pabandykite atlikti šiuos veiksmus:
1. Patikrinkite kiekvieną jungiklio prievado šviesos diodą ir įsitikinkite, kad eterneto kabelis yra tinkamai prijungtas. 2. Išbandykite kitą jungiklio prievadą ir įsitikinkite, kad Ethernet kabelis yra tinkamas ir veikia normaliai. 3. Išjunkite jungiklį ir po kurio laiko vėl įjunkite. 4. Įsitikinkite, kad jūsų kompiuterio IP adresas nustatytas jungiklio potinklyje. 5. Jei vis tiek negalite pasiekti konfigūracijos puslapio, iš naujo nustatykite jungiklio gamyklinius nustatymus. Tada
jūsų kompiuterio IP adresas turi būti nustatytas kaip 192.168.0.x ("x" yra bet koks skaičius nuo 2 iki 254), o potinklio kaukė - 255.255.255.0.
4 klausimas. Kodėl terminalo emuliacijos programa rodoma netinkamai? Pabandykite atlikti šiuos veiksmus:
1. Įsitikinkite, kad maitinimo šaltinis yra normalus, o konsolės laidas tinkamai prijungtas. 2. Patikrinkite, ar konsolės kabelis yra tinkamo tipo. 3. Įsitikinkite, kad terminalo emuliacijos programos parametrai yra teisingi: sukonfigūruokite bitus per sekundę
kaip 38400, duomenų bitai kaip 8, paritetas kaip nėra, stabdymo bitai kaip 1 ir srauto valdymas kaip nėra.
32 A priedas Trikčių šalinimas
Omada C.ampus Stackable L3 Managed Switch
B priedas Specifikacijos
Specifications for S6500 Series Switches
Prekė
Turinys
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
Standartai
IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)
IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)
10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)
S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54
B priedas. Specifikacijos 33
Omada C.ampus Stackable L3 Managed Switch
„PoE“ biudžetas
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)
Operating Temperature & Altitude
For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters
Laikymo temperatūra nuo -40 °C iki 70 °C (nuo -40 °F iki 158 °F)
Darbinė drėgmė nuo 10 % iki 90 % santykinis drėgnis Nekondensuojantis
Sandėliavimas Drėgmė
Nuo 5% iki 90% RH Nekondensuojantis
34 B priedas. Specifikacijos
Omada C.ampus Stackable L3 Managed Switch
Specifications for S7500 Series Switches
Prekė
Turinys
Standartai
IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)
1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)
LED
Operating Temperature & Altitude
S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
Laikymo temperatūra nuo -40 °C iki 70 °C (nuo -40 °F iki 158 °F)
Darbinė drėgmė nuo 10 % iki 90 % santykinis drėgnis Nekondensuojantis
Sandėliavimas Drėgmė
Nuo 5% iki 90% RH Nekondensuojantis
For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Palaikomas aukštis yra nuo jūros lygio iki 5000 m. Reikėtų atkreipti dėmesį, kad kai aukštis viršija 2000 m, kaskart padidėjus 220 metrų, maksimali darbinė temperatūra sumažės 1 °C (1.8 °F).
B priedas. Specifikacijos 35
Omada C.ampus Stackable L3 Managed Switch
Maitinimo modulių specifikacijos
PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)
Maitinimo įvestis
100 V240 V~ 50/60 Hz 8A
100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)
100 V240 V~ 50/60 Hz 7A
Išėjimas ttage
Primary: 53.5 VDC Standby: 12 VDC
Primary: 53.5 VDC Standby: 12 VDC
Primary: 12 VDC Standby: 12 VDC
Išėjimo srovė
9.35 A (maks.)
16.5 A (maks.)
45 A (maks.)
Išėjimo galia
500 W (maks.)
900 W (maks.)
550 W (maks.)
Darbinis aukštis
For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m
36 B priedas. Specifikacijos
CE ženklo įspėjimas
Tai A klasės gaminys. Buitinėje aplinkoje šis gaminys gali sukelti radijo trukdžius, tokiu atveju naudotojo gali tekti imtis atitinkamų priemonių.
ES atitikties deklaracija
„TP-Link“ pareiškia, kad šis komutatorius atitinka esminius reikalavimus ir kitas atitinkamas direktyvų 2014/30/ES, 2014/35/ES, 2011/65/ES ir (ES) 2015/863 nuostatas. Originalią ES atitikties deklaraciją galite rasti adresu https://www.tp-link.com/en/support/ce/
JK atitikties deklaracija
„TP-Link“ pareiškia, kad šis komutatorius atitinka esminius reikalavimus ir kitas atitinkamas 2016 m. Elektromagnetinio suderinamumo reglamento ir 2016 m. Elektros įrangos (saugos) reglamento reikalavimus. Originalią JK atitikties deklaraciją galite rasti adresu https://www.tp-link.com/support/ukca/
, .
ATSARGIAI:
Dvipolis, neutralus lydiklis. Prieš atlikdami techninę priežiūrą, atjunkite nuo tinklo.
Saugos informacija
· Saugokite prietaisą nuo vandens, ugnies, drėgmės ar karštos aplinkos. · Nebandykite išardyti, taisyti ar modifikuoti įrenginio.Jei reikia priežiūros, susisiekite su mumis. · Padėkite prietaisą apatiniu paviršiumi žemyn. · Maitinimo laido kištukas naudojamas kaip atjungimo įtaisas, kištukinis lizdas turi būti
lengvai pasiekiamoje vietoje. · Prijunkite gaminį prie įžemintų sieninių lizdų per maitinimo laidą.
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
baterijos.
· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.
Perskaitykite ir vadovaukitės aukščiau pateikta saugos informacija, kai naudojate įrenginį. Negalime garantuoti, kad dėl netinkamo prietaiso naudojimo nebus nelaimingų atsitikimų ar žalos. Naudokite šį gaminį atsargiai ir prisiimkite atsakomybę.
Jei reikia techninės pagalbos, vartotojo vadovų ir kitos informacijos, apsilankykite https://support.omadanetworks.com/ arba tiesiog nuskaitykite QR kodą.
© 2026 „TP-Link“ 7100002759 REV2.0.1
Dokumentai / Ištekliai
![]() |
Omada L3 Campus Stackable Managed Switch [pdf] Naudotojo vadovas L3 Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch |