SoliTek SOLID Series Solar Modules

Naudojimo instrukcijos
- Read this guide entirely before installation.
- This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
- This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
- All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
- This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
- It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
- The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
- Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
- Jei nesilaikysite šiame vadove pateiktų nurodymų, galite sugadinti sistemos komponentus, sukelti pavojų personalui, sugadinti turtą arba panaikinti skydelio garantiją.
- Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.
BENDRIEJI REIKALAVIMAI
- Prieš diegdami perskaitykite visą šį vadovą.
- Šio dokumento tikslas – pateikti minimalius reikalavimus ir rekomendacijas saugiam ir sėkmingam SoliTek PV modulių montavimui.
- Šiame dokumente taip pat pateikiami reikalavimai, būtini norint išlaikyti SoliTek PV modulio atitiktį IEC 61215, IEC 61730, UL 61730 standartams.
- Šiame vadove pateikiama pagrindinė informacija apie UAB “SoliTek Cells” SOLID serijos fotovoltinius modulius, jų montavimą ir saugų tvarkymą. Prieš pradedant montuoti, reikia perskaityti ir suprasti visas instrukcijas. Jei turite klausimų, susisiekite su pardavėju arba UAB „SoliTek Cells“, kad gautumėte daugiau informacijos.
- This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
- It serves as a general but strictly mandatory reference for the Installer.
- Pažeidus arba netiksliai laikantis šios dokumentacijos punkto, garantija anuliuoja.
- Montuotojas turi suprasti ir laikytis visų galiojančių vietinių, valstijų ir federalinių pastatų statybos, elektros projektavimo, gaisro ir saugos taisyklių bei standartų, taip pat turi pasitarti su vietos valdžios institucijomis, kad nustatytų taikomus leidimų išdavimo reikalavimus, prieš pradėdamas montuoti ar prižiūrėti PV modulius. susipažinti su mechaniniais ir elektriniais reikalavimais fotovoltinėms sistemoms.
- Jei nesilaikysite šiame vadove pateiktų nurodymų, galite sugadinti sistemos komponentus, sukelti pavojų personalui, sugadinti turtą arba panaikinti skydelio garantiją.
- PV sistemas ant stogo turėtų montuoti tik tuose būstuose, kurių konstrukcijų vientisumas buvo oficialiai ištirtas ir patvirtintas, kad sertifikuotas statybos specialistas arba inžinierius gali atlaikyti papildomą svertinę fotovoltinės sistemos komponentų, įskaitant PV modulius, apkrovą.
- For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
- For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
- Plokščios plokštės PV modulio konstrukciją sudaro laminuotas saulės elementų mazgas, įdėtas į izoliacinę medžiagą dviejuose stiklo lakštuose.
- Laikykite šią dokumentaciją saugioje vietoje, kad galėtumėte pasinaudoti ateityje.
- Nebandykite išardyti modulio ir nenuimkite jokių pritvirtintų vardinių lentelių ar komponentų! Tai padarius, garantija nebegalios.
Tvarkymas ir taikymas
TVARKYMAS
- SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
- Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
- Neviršykite didžiausio sukrautų padėklų aukščio, nurodyto ant padėklų pakuotės.
- Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
- SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
- Do not exert mechanical stress on the cables.
- Never step on PV modules or drop or place heavy objects on them.
- Be careful when placing PV modules on hard surfaces and secure them from falling.
- Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
- Broken or damaged PV modules must be handled carefully and disposed of properly.
TAIKYMAS
Apribojimai
- SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
- PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
- Do not install modules above 2000 m (6561 ft) altitude above sea level
- Dirbtinai koncentruota šviesa neturi būti nukreipta į SoliTek PV modulius.
Rekomendacijos
- SoliTek rekomenduoja PV modulius montuoti mažiausiai 10 laipsnių pasvirimo kampu, kad būtų galima tinkamai išsivalyti nuo lietaus.
- Dalinis arba visiškas PV modulio ar modulių šešėliavimas gali žymiai sumažinti sistemos našumą.
- SoliTek rekomenduoja sumažinti šešėlių kiekį per metus, kad padidėtų PV modulių gaminamos energijos kiekis.
- Aukštos sistemos ttages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
- The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage šuoliai.
- Geresnė modulių ventiliacija ir trumpesni jungiamieji kabeliai padidina elektros energijos gamybą.
Bifacialiems moduliams:
- Rekomenduojama padidinti PV plokštės aukštį nuo žemės, kad daugiau šviesos galėtų keliauti po moduliu ir tada atspindėti
- Bifacialinis padidėjimas žymiai padidėja, jei moduliai montuojami virš baltų (didelė albedo vertė), šviesą atspindinčių paviršių.
Elektros instaliacija
SAUGUMAS
- PV moduliai gali gaminti srovę ir tūrįtage veikiant bet kokio intensyvumo šviesai. Elektros srovė didėja esant didesniam šviesos intensyvumui. DC ttag50 voltų ar didesnė e gali būti mirtina. Susisiekus su PV sistemos, veikiančios šviesoje, srovės grandinė gali sukelti mirtiną elektros smūgį.
- Išjunkite PV modulius, visiškai pašalindami juos nuo šviesos arba padengdami priekinį paviršių nepermatoma medžiaga. Dėl įtampingo elektros įrangos saugos taisyklių dirbant su moduliais, kuriuos veikia bet kokia šviesa. Dirbdami su PV moduliais naudokite izoliuotus įrankius ir nedėvėkite metalinių papuošalų.
- Kad išvengtumėte lanko ir elektros smūgio, neatjunkite elektros jungčių esant apkrovai. Netinkamos jungtys taip pat gali sukelti lanką ir elektros smūgį. Laikykite jungtis sausas ir švarias ir įsitikinkite, kad jos tinkamai veikia. Niekada nekiškite metalinių daiktų į jungtis ir jokiu būdu jų nekeiskite, kad užtikrintumėte elektros jungtį.
- Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
- The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
- Saulės fotovoltinių sistemų įrengimas reikalauja specialių įgūdžių ir žinių. Tai turėtų atlikti tik kvalifikuotas ir specialiai instruktuotas personalas. Montuotojas prisiima visą sužalojimo riziką, įskaitant elektros smūgio pavojų.
- Naudokite tik įrangą, jungtis, laidus ir tvirtinimo įrangą, specialiai sukurtą naudoti fotovoltinėje sistemoje.
- Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
- Atjungiant laidus, prijungtus prie fotovoltinio modulio, kurį veikia šviesa, gali susidaryti elektros lankas. Lankai gali nudeginti, sukelti gaisrą arba kitaip sukelti saugos (iki mirtino elektros smūgio) problemų.
- Patikrinkite likusį tūrįtage before starting and observe the local safety-relevant regulations for such working conditions.
- Įprastomis sąlygomis fotovoltinis modulis gali gaminti daugiau srovės ir (arba) tūriotage (čia: 30 V DC), nei nurodyta standartinėmis bandymo sąlygomis.
- Susisiekite su DC ttage 30 V ar daugiau yra potencialiai pavojingas. Būkite atsargūs prijungdami laidus arba dirbdami su moduliais, kuriuos veikia saulės spinduliai.
- Nuosekliai junkite tik tos pačios nominalios išėjimo srovės modulius. Jei moduliai jungiami nuosekliai, bendra ttage lygi atskiro modulio sumai ttages.
- Prijunkite tik to paties tūrio modulius arba serijinius modulių deriniustage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
- Tam tikroje fotoelektrinėje sistemoje visada naudokite to paties tipo modulius.
- If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
- Naudokite atitinkamą saugos įrangą (izoliuotus įrankius, dielektrines pirštines, batus ir kt.), patvirtintą naudoti elektros instaliacijose.
KONFIGŪRACIJA
- Įprastomis sąlygomis fotovoltinis modulis gali susidurti su sąlygomis, kurios sukuria daugiau srovės ir (arba) tūriotage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (LOJ) turėtų būti padaugintas iš koeficiento iki 1.25, atsižvelgiant į žemiausią ir aukščiausią aplinkos temperatūrą, užregistruotą įrengimo vietoje, nustatant komponento tūrįtage nominalai, laidininko srovės vardinės vertės, saugiklių dydžiai ir prie PV išvesties prijungtų valdiklių dydis.
- ttages yra adityvus, kai PV moduliai jungiami tiesiogiai nuosekliai, o modulių srovės yra papildomos, kai PV moduliai jungiami tiesiogiai lygiagrečiai. Skirtingų elektrinių charakteristikų PV modulių negalima jungti tiesiogiai nuosekliai. Naudojant tinkamus trečiųjų šalių elektroninius įrenginius, prijungtus prie PV modulių, gali būti prijungtos skirtingos elektros jungtys, todėl jie turi būti montuojami pagal gamintojo nurodytas instrukcijas.
- Didžiausias ttage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Taip pat didžiausias įvesties tūristagReikia atsižvelgti į keitiklio ir kitų sistemos elektrinių prietaisų e. Atviros grandinės ttage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
- Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.
APSAUGOS NUO VIRŠSROVĖS PRIETAISAS (OCPD)
- When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
- An overcurrent protection device is required for each series string if more than two series are connected in parallel.
- In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
- The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
- Saugiklis amp įvertinimas ≥ 1.25 x Isc
- Turimų PV saugiklių kataloge pasirinkite kitą aukštesnį standartinį įvertinimą.
- Isc = vieno modulio trumpojo jungimo srovė esant standartinėms bandymo sąlygoms (STC).
- Atsižvelgiant į SoliTek modulių Isc vertes, tinkama PV saugiklių vertė, kurią reikia naudoti įrenginyje, yra 30 A. SoliTek rekomenduoja naudoti PV saugiklius tiek teigiamuose, tiek neigiamuose laiduose.
KABELIS IR LAIDAI
SoliTek PV moduliai tiekiami su dviem standartiniais saulės šviesai atspariais išvesties kabeliais, kurie baigiami PV jungtimis, paruoštomis daugeliui įrenginių. Teigiamas (+) gnybtas turi išorinę jungtį, o neigiamas (-) gnybtas turi moterišką jungtį. Modulio laidai yra skirti nuoseklioms jungtims (ty, kištukinėms (+) ir moteriškoms (-) jungtims), bet taip pat gali būti naudojamos prijungti tinkamus trečiųjų šalių elektros įrenginius, kurie gali turėti alternatyvias laidų konfigūracijas, jei laikomasi gamintojo nurodymų.
Naudokite lauko laidus su tinkamo skerspjūvio plotu, kuris yra patvirtintas naudoti esant didžiausiai PV modulio trumpojo jungimo srovei. Visi laidai turi būti su dviguba izoliacija, susietais kabeliais, kurių minimali vardinė įtampa yra 1,8 kV (virš 1500 V tūrio).tage) ir mažiausia vardinė temperatūra 90 ˚C (190 °F). Vielos dydis ne mažesnis kaip 4 mm² (12 AWG). Izoliacijos tipas turi atitikti naudojamo montavimo metodo tipą ir atitikti IEC 61730 ir II saugos klasės reikalavimus.
- Izoliacijos lygis: 1,8 kV (laidininkas-laidininkas).
- Temperatūra: mažiausiai nuo -40 °C iki +90 °C (nuo -40 °F iki 190 °F).
- Laidininko konstrukcija: alavuota suvyta varinė viela, kurios vario grynumas didesnis nei 99,9%.
- Pirminė izoliacija: susietas polietilenas (XLPE), atsparus saulės spinduliams ir drėgmei, antipirenas. Tinka po žeme įrengtiems vamzdynams ir bėgimo takams.
- Izoliacija (striukė): termoplastinė, atspari saulės spinduliams, antipireninė, atspari vandeniui.
- Minimalus išorinis kabelio skersmuo su izoliacija – 5,2 mm (2,05 colio).
- Minimalus laidininko skerspjūvis – 4 mm² (12 AWG).
SoliTek rekomenduoja montuotojams naudoti tik saulės šviesai atsparius laidus, tinkamus nuolatinės srovės (DC) laidams PV sistemose. Kabeliai turi būti pritvirtinti prie tvirtinimo konstrukcijos taip, kad būtų išvengta mechaninių kabelio ir (arba) modulio pažeidimų. Nedarykite įtempių kabelių. Tvirtinimui naudokite tinkamas priemones, tokias kaip saulės spinduliams atsparūs kabelių raiščiai ir (arba) laidų valdymo spaustukai. Nors kabeliai yra atsparūs saulės spinduliams ir vandeniui, jei įmanoma, venkite tiesioginių saulės spindulių ir kabelių nepanerkite į vandenį.
Standartinis kabelių ilgis iš jungiamųjų dėžių yra 1,2 m (47,24 colio). Numatyta, kad sistemoje būtų sujungtos dvi plokštės.
ĮŽEMINIMAS
- Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:
Framed type modules grounding
Ant rėmo įžeminimo ženklu pažymėtos skylės gali būti naudojamos tik įžeminimui. Negręžkite papildomų įžeminimo angų ant modulio rėmo.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Tada įžeminimo laidininkas turi būti prijungtas prie žemės, naudodamas tinkamą įžeminimo elektrodą.
A bolted connection is required; it incorporates:
- M4 dydžio varžtas.
- Dantų poveržlė po varžto galvute arba dantytas varžtas turi prasiskverbti pro nelaidžias dangas, tokias kaip anoduotas rėmas.
- Tvirtinimo veržlė, tinkama M4 varžtui.
- Visa techninė įranga turi būti iš spalvotojo metalo, 300 serijos nerūdijančio plieno arba tinkamai apsaugota nuo korozijos.
- Rekomenduojamas veržlės užfiksavimo sukimo momentas yra 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
- Įžeminimo varžtas turi eiti per visus jungiamuosius elementus.

- Įrenginiams, išvardytiems ir identifikuotiems, skirtiems PV modulių metaliniams rėmams įžeminti, leidžiama įžeminti atvirus metalinius modulio rėmus prie įžemintų tvirtinimo konstrukcijų.
- In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
- Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
- Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.
Frameless type modules grounding
- Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.
JUNGTYS
- Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
- Nemėginkite elektros jungties su šlapiomis, nešvariomis ar kitaip sugedusiomis jungtimis.
- Venkite saulės spindulių ir jungčių panardinimo į vandenį. Venkite jungčių remtis į žemę arba stogo paviršių.
- Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
- Patikrinkite, ar visos elektros jungtys yra tvirtai pritvirtintos. Įsitikinkite, kad visos fiksavimo jungtys yra visiškai užsifiksavusios ir užfiksuotos.
DIODAI
The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Apėjimo diodai nėra apsaugos nuo viršsrovių įtaisai. Aplenkimo diodai nukreipia srovę nuo elementų eilučių dalinio užtemdymo atveju. Šių diodų charakteristikos:
- ttage reitingas – 50 V.
- Srovė – 25 A.
GAISRINĖS KLASĖS ĮVERTINIMAS
- SoliTek SOLID Bifacial ir Blackstar moduliai buvo patvirtinti IEC ugnies bandymu ir pasiekė A degumo klasę. Ugnies bandymas buvo atliktas esant 127 mm (5 colių) pokrypiui per 300 mm (11,81 colio), kaip nurodyta IEC 2.5-61730 A.2 punkte.
- SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.
Mechaninis tvirtinimas
- The mechanical loads described in this manual are the test loads.
- For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.
BENDRIEJI REIKALAVIMAI
- Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
- Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
- If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
- Laikykitės saugos taisyklių ir montavimo instrukcijų, pateiktų kartu su montavimo sistema. Jei reikia, dėl papildomos informacijos susisiekite tiesiogiai su tiekėju.
- The modules must be safely set onto the mounting rail.
- The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
- The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
- Before installing modules on a roof, ensure that the roof construction is suitable.
- In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
- Įsitikinkite, kad tvirtinimo bėgelis nesideformuotų ir nepaveiks modulių, kai plečiasi dėl šiluminio plėtimosi.
- The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
- Nebandykite gręžti skylių stiklo paviršiuje ir modulių rėmuose, nes tai panaikins garantiją.
- The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.
Montavimo komponentai turi būti pagaminti iš patvarių, antikorozinių ir UV spinduliams atsparių medžiagų (rekomenduojami nerūdijančio plieno ir anoduoto aliuminio komponentai).
MONTAVIMAS SU CLAMPS
- Naudokite ne mažiau kaip 4 laminato klamps pritvirtinti modulius ant montavimo bėgelių. Moduliai klamps metalinės dalys neturi liestis su priekiniu arba galiniu stiklu. Renkantis tokio tipo klamp-montavimo būdas, naudokite ne mažiau kaip keturis clamps kiekviename modulyje; du klamps turi būti pritvirtinti kiekvienoje ilgoje pusėje. Priklausomai nuo vietinių vėjo ir sniego apkrovų, papildomai klamps gali prireikti siekiant užtikrinti, kad moduliai galėtų atlaikyti apkrovą.
- Clamps priveržimo sukimo momentas turi būti ne mažesnis kaip 15 Nm (11,06 pėdų svarų), bet ne didesnis kaip 20 Nm (14,75 pėdų svarų). Paprastai 15 Nm (11,06 ft-lb) pasiekiamas, kai du aliuminio profesionalaifiles liesti vienas kitą. Kai modulis montuojamas vertikaliai ant šlaitinio stogo, kurio nuolydis >45°, modulio apačioje reikalingas papildomas kabliukas.

SOLID Black, Semi-clear, Satin, Agro Frameless
Su skersiniais bėgiais


BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting
- Renkantis tokio tipo clamp-montavimo būdas, naudokite ne mažiau kaip keturis clamps kiekviename modulyje; du klamps turi būti pritvirtinti kiekvienoje modulio pusėje. Moduliai klamps neturi liestis su priekiniu stiklu ir neturi deformuoti rėmo.
- Būtinai venkite šešėlio poveikio saulės elementams iš modulio clamps.
- The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
- cl ilgisamp should be at least 30 mm (1,18 inch).
- Klamp turi persidengti modulio rėmą bent 5 mm (0,2 colio), bet ne daugiau kaip 10 mm (0,4 colio).
Su skersiniais bėgiais

Be skersinių bėgių arba bėgiai yra statmeni ilgajam šoniniam rėmui

Su įvedimo sistema

Montavimas varžtais
- Modulis turi būti pritvirtintas ir paremtas keturiais M8 nerūdijančio plieno varžtais per nurodytas tvirtinimo angas ant skersinių strypų. Sukimo momentas ant klamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
- If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clampreikia pasirinkti techninę įrangą.

- Mounting with bolts can be done only through dedicated predrilled holes in the frame.
- Gręžti naujas skyles draudžiama, todėl garantija negalios.

SUJUNGIMO DĖŽĖS PADĖTIS
- Norėdami sužinoti atstumą tarp jungiamosios dėžutės ir modulio krašto arba kitus jungties dėžutės padėties ir plotų matmenis, žr. toliau pateiktus paveikslus.

PRIEŽIŪRA
- Siekdama užtikrinti optimalų modulio veikimą, SoliTek rekomenduoja:
- Jei reikia, stiklinę modulio priekinę dalį galima nuvalyti vandeniu ir minkšta kempine arba šluoste.
- Įsisenėjusioms dėmėms pašalinti galima naudoti švelnų, neabrazyvinį ploviklį.
- Reguliariai tikrinkite elektros ir mechanines jungtis ir įsitikinkite, kad jos yra švarios, saugios, sukomplektuotos ir patikimos.
- Iškilus problemai, pasikonsultuokite su licencijuotu/kvalifikuotu asmeniu.
SPECIFIKACIJOS
| Parametras \ Modelis | BLACKSTAR B.96 | SOLID Black (Semi-Clear) B.96 35(40) mm | BLACKSTAR Satin B.96 | MAGNUS B.108 |
| Bandymo sąlygos | STC | STC | STC | STC |
| Nominali galia | 455 W | 455 W | 445 W | 510 W |
| Elektriniai duomenys @STC | ||||
| Didžiausia galia (Pmax), W | 455 | 455 | 445 | 510 |
| ttage esant maksimaliai galiai (Vmpp), V | 29,71 | 29,71 | 29,40 | 33,34 |
| Srovė esant maksimaliai galiai (Impp), A | 15,31 | 15,31 | 15,14 | 15,30 |
| Open Circuit Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 39,06 |
| Trumpojo jungimo srovė (ISc), A | 15,97 | 15,97 | 15,79 | 15,95 |
| Šiluminiai duomenys | ||||
| Darbinės temperatūros diapazonas | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) |
| Temperatūros koeficientas Pmax | -0,362 %/°C (°F) | -0,362 %/°C (°F) | -0,362 %/°C (°F) | -0,362 %/°C (°F) |
| Temperatūros koeficientas Voc | -0,265 %/°C (°F) | -0,265 %/°C (°F) | -0,265 %/°C (°F) | -0,265 %/°C (°F) |
| Temperatūros koeficientas Isc | +0,036 % /° C (°F) | +0,036 % /° C (°F) | +0,036 % /° C (°F) | +0,036 % /° C (°F) |
| Duomenys apie dydį ir svorį | ||||
| Ilgis | 1762 mm | 1762 mm | 1762 mm | 1961 mm |
| Plotis | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Storis | 30 mm | 35(40) mm | 30 mm | 30 mm |
| Svoris | 25,5 kg | 35(36) kg | 25,5 kg | 28,5 kg |
| Montavimo būdas | ||||
| Reference to the chapter | 3.3 | 3.3 | 3.3 | 3.3 |
| Kita | ||||
| Didžiausia atvirkštinė srovė, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/II tipas | |||
| Maksimalus sistemos ttage, V | 1500 | |||
Table 9. Electrical and mechanical parameters table.
| Parametras \ Modelis | KIETAS Semi- clear B.96 | SOLID Black B.96 | KIETAS Satin B.96 | KIETAS Agro B.64 |
| Bandymo sąlygos | STC | STC | STC | STC |
| Nominali galia | 455 W | 455 W | 445 W | 300 W |
| Elektriniai duomenys @STC | ||||
| Didžiausia galia (Pmax), W | 455 | 455 | 445 | 300 |
| ttage esant maksimaliai galiai (Vmpp), V | 29,71 | 29,71 | 29,40 | 19,60 |
| Srovė esant maksimaliai galiai (Impp), A | 15,31 | 15,31 | 15,14 | 15,31 |
| Open Circuit Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 22,76 |
| Trumpojo jungimo srovė (ISc), A | 15,97 | 15,97 | 15,79 | 15,97 |
| Šiluminiai duomenys | ||||
| Darbinės temperatūros diapazonas | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) |
| Temperatūros koeficientas Pmax | -0,30 %/°C (°F) | -0,30 %/°C (°F) | -0,30 %/°C (°F) | -0,30 %/°C (°F) |
| Temperatūros koeficientas Voc | -0,25 %/°C (°F) | -0,25 %/°C (°F) | -0,25 %/°C (°F) | -0,25 %/°C (°F) |
| Temperatūros koeficientas Isc | +0,045 % /° C (°F) | +0,045 % /° C (°F) | +0,045 % /° C (°F) | +0,045 % /° C (°F) |
| Duomenys apie dydį ir svorį | ||||
| Ilgis | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm |
| Plotis | 1144±2 | 1144±2 | 1144 ± 2 mm | 1144 ± 2 mm |
| Storis | 7,2 mm | 7,2 mm | 7,2 mm | 7,2 mm |
| Svoris | 33 kg | 33 kg | 33 kg | 33 kg |
| Montavimo būdas | ||||
| Reference to the chapter | 3.2 | 3.2 | 3.2 | 3.2 |
| Kita | ||||
| Didžiausia atvirkštinė srovė, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/II tipas | |||
| Maksimalus sistemos ttage, V | 1500 | |||
Table 10. Electrical and mechanical parameters table.
| Parametras \ Modelis | SOLID Satin B.96 35 mm | SOLID Satin B. 96 40 mm | SOLID AgroB.64 35 mm | SOLID AgroB.64 40 mm |
| Bandymo sąlygos | STC | STC | STC | STC |
| Nominali galia | 445 W | 445 W | 300 W | 300 W |
| Elektriniai duomenys @STC | ||||
| Didžiausia galia (Pmax), W | 445 | 445 | 300 | 300 |
| ttage esant maksimaliai galiai (Vmpp), V | 29,40 | 29,40 | 19,60 | 19,60 |
| Srovė esant maksimaliai galiai (Impp), A | 15,14 | 15,14 | 15,31 | 15,31 |
| Open Circuit Voltage (Voc), V | 34,40 | 34,40 | 22,78 | 22,78 |
| Trumpojo jungimo srovė (ISc), A | 15,79 | 15,79 | 15,97 | 15,97 |
| Šiluminiai duomenys | ||||
| Darbinės temperatūros diapazonas | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) | -40°C ÷ 85oC (-40°F ÷ 185°F) |
| Temperatūros koeficientas Pmax | -0,362 %/°C (°F) | -0,362 %/°C (°F) | -0,30 %/°C (°F) | -0,30 %/°C (°F) |
| Temperatūros koeficientas Voc | -0,265 %/°C (°F) | -0,265 %/°C (°F) | -0,25 %/°C (°F) | -0,25 %/°C (°F) |
| Temperatūros koeficientas Isc | +0,036 % /° C (°F) | +0,036 % /° C (°F) | +0,045 % /° C (°F) | +0,045 % /° C (°F) |
| Duomenys apie dydį ir svorį | ||||
| Ilgis | 1762 mm | 1762 mm | 1762 mm | 1762 mm |
| Plotis | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Storis | 35 mm | 40 mm | 35 mm | 40 mm |
| Svoris | 35 kg | 36 kg | 35 kg | 36 kg |
| Montavimo būdas | ||||
| Reference to the chapter | 3.3 | |||
| Kita | ||||
| Didžiausia atvirkštinė srovė, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/II tipas | |||
| Maksimalus sistemos ttage, V | 1500 | |||
Table 11.Electrical and mechanical parameters table.
- The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
- Visos SoliTek SOLID PV plokštės atitinka II elektros saugos klasę.
Atsakomybės atsisakymas
- Kadangi SoliTek negali kontroliuoti fotovoltinės sistemos įrengimo, veikimo, taikymo ir priežiūros pagal šią instrukciją. SoliTek neprisiima atsakomybės ir aiškiai atsisako atsakomybės už bet kokius nuostolius, žalą ar išlaidas, atsiradusias dėl tokio įrengimo, naudojimo, naudojimo ar priežiūros arba bet kokiu būdu su juo susijusius.
- SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
- The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.
DUK
- Q: What should I do before installing the PV modules?
- A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
- Q: Can I install the PV modules myself without professional training?
- A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
- Q: What happens if I don’t follow the instructions in this guide?
- A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
- Q: Is it safe to work on a rooftop during installation?
- A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
- Q: How should I store the PV modules before installation?
- A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.
Dokumentai / Ištekliai
![]() | SOLID Series Solar Modules |
Nuorodos
- solitek.euwww.solitek.eu
- Vartotojo vadovasmanual.tools